roofy

215 West 16 Street

Manhattan, NY 10011BBL 1-00766-0032Map

Owner of record: Metre West Realty LLC

215 West 16 Street is a walk-up apartment building built in 1920 in Manhattan, 10011. It has 16 residential units across 5 floors. The owner of record is Metre West Realty LLC. HPD has recorded 28 housing violations here, most recently on June 4, 2025. City tax records listed 15 rent-stabilized apartments here in 2024.

HPD violations
28
DOB violations
4
ECB violations
3
HPD complaints
2

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Jun 4, 2025

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
15
About 94% of the building's 16 apartments
Up from 14 in 2018

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 28

  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Jun 4, 2025

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 1, 2024

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 15, 2023

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 2, 2022

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Feb 16, 2022

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 1, 2021

    Closed — Violation dismissed
  • A

    Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected at public hall, 1st story

    Mar 26, 2018

    Closed — Violation closed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 6, 2017

    Closed — Violation dismissed
  • C

    Make safe by properly repairing the structural defect east parapet wall leaning outward approx 2 inches at front section roof

    Apr 1, 2016

    Closed — Violation closed
  • C

    Make safe by properly repairing the structural defect west roof parapet wall leaning inward approx 6 inches and 20 feet long at center

    Apr 1, 2016

    Closed — Violation closed
Show 18 more ↓
  • C

    Make safe by properly repairing the structural defect spalling brickwork at building front from 5 story to roof approx 120 square feet

    Apr 1, 2016

    Closed — Violation closed
  • B

    Properly repair with similar material the broken or defective brick and mortal joints at chimney roof rear

    Apr 1, 2016

    Closed — Violation closed
  • B

    And dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes air conditioner 5 story balcony building front

    Apr 1, 2016

    Closed — Violation closed
  • B

    And dept. rules and regulations. remove the encumbrance obstructing egress from fire escapes household items 5 story balcony building rear stack

    Apr 1, 2016

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective masonry lintel over west window front of building , 1st story

    Apr 1, 2016

    Closed — Violation closed
  • C

    Properly repair with similar material the broken or defective brick and mortar joints at building front areaway

    Apr 1, 2016

    Closed — Violation closed
  • B

    Properly repair with similar material the broken or defective spalling masonry at bottom of east and west columns at building front entrance to building

    Apr 1, 2016

    Closed — Violation closed
  • C

    Properly repair with similar material the broken or defective brick and mortar joints west wall of east section building front 1 story

    Apr 1, 2016

    Closed — Violation closed
  • C

    Replace with new the broken or defective metal lintel over east window at building front 5 story

    Apr 1, 2016

    Closed — Violation closed
  • A

    Paint metal in accordance with dept. regulation fire escapes all stories building front

    Apr 1, 2016

    Closed — Violation closed
  • B

    Properly repair the broken or defective paving front areaway building front

    Apr 1, 2016

    Closed — Violation closed
  • A

    Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agency?s housing information guide. a sample notice can be found at www.nyc.gov/hpd. at public hall, 1st story

    Apr 1, 2016

    Closed — Violation closed
  • A

    Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper. at public hall, 1st story

    Apr 1, 2016

    Closed — Violation closed
  • C

    Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system at public hall, 1st story

    Apr 1, 2016

    Closed — Violation closed
  • A

    Post a proper notice of carbon monoxide detecting device requirements, in a form approved by the commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in a private dwelling. at public hall, 1st story

    Apr 1, 2016

    Closed — Violation closed
  • A

    Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mail box at public hall, 1st story

    Apr 1, 2016

    Closed — Violation closed
  • A

    § 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor at public hall, 1st story

    Apr 1, 2016

    Closed — Violation closed
  • C

    Make safe by properly repairing the structural defect building front parapet wall exterior brick and mortar , 5th story

    Mar 31, 2016

    Closed — Violation closed

DOB building violations · 4

  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 19, 2007

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 19, 2003

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 18, 1993

    Dob violation - dismissed

ECB violations · 3

  • Class - 2

    As per one weil mclain 780 in cellar. manual reset low water cutoff not installed.

    Nov 29, 2021 · Penalty $625

    Resolve
  • Class - 1

    Failure to maintain the exterior walls the brick work at the front (south) parapet is weathered and defective throughout.rmdy: make repairs, maintain in a code compliant manner.

    Apr 2, 2016

    Resolve
  • Class - 2

    Failure to maintain exterior bldg wall or appurtenances. at parapet exp#1 left side loose & defetive brick work at coping. remedy: maintain exterior bldg wall.

    Apr 1, 2016 · Penalty $500

    Resolve

Complaints

  • Unsanitary condition

    Sewage

    Aug 27, 2026 · Apt 1FW

    Close
  • Heating

    Heat related

    Jan 25, 2009 · Apt 2E

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C4)
Year built
1920
Floors
5
Residential units
16
Building area
8,855 ft²
Lot area
2,300 ft²
Zoning
R8B
Community board
104
Council district
3
Block / lot
766 / 32
Assessed value
$675,450
Landmark / historic district
No

HPD registration #103770, last renewed Aug 27, 2025.

Questions about 215 West 16 Street

Who owns 215 West 16 Street?

The owner of record in NYC Department of City Planning PLUTO data is Metre West Realty LLC.

Does 215 West 16 Street have violations?

Yes. NYC HPD has recorded 28 housing violations at this property.

Is 215 West 16 Street rent stabilized?

NYC Department of Finance tax bills listed 15 rent-stabilized units here in 2024 (about 94% of its 16 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 215 West 16 Street built?

City records list 1920 as the year it was built.

How many apartments are in 215 West 16 Street?

It has 16 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.