140 West 4 Street
Manhattan, NY 10012BBL 1-00543-0047Map
Owner of record: Keystone 140-142 West Fourth LLC
140 West 4 Street is a walk-up apartment building built in 1900 in Manhattan, 10012. It has 24 residential units across 6 floors. The owner of record is Keystone 140-142 West Fourth LLC. HPD has recorded 69 housing violations here, most recently on April 1, 2024. City tax records listed 7 rent-stabilized apartments here in 2024.
- HPD violations
- 69
- DOB violations
- 3
- ECB violations
- 21
- HPD complaints
- 73
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.
Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 69
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 1, 2024
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Mar 15, 2023
Closed — Violation dismissed - CImmediately hazardous
Properly secure the loose ...iron handrail at stairs leading to basement at center court
Oct 5, 2022
Closed — Violation dismissed - BHazardous
Properly repair with similar material the broken or defective waterproofing materials at bulkhead exterior walls
Oct 5, 2022
Closed — Violation dismissed - CImmediately hazardous
Abate the infestation consisting of mice at basement
Oct 5, 2022
Closed — Violation dismissed - CImmediately hazardous
Abate the infestation consisting of roaches at basement
Oct 5, 2022
Closed — Violation dismissed - BHazardous
Properly repair with similar material the broken or defective loose brick and missing mortar at south parapet wall at interior
Oct 5, 2022
Closed — Violation dismissed - BHazardous
Provide doorknobs for re-entry to the building from the roof at bulkhead
Oct 5, 2022
Closed — Violation dismissed - CImmediately hazardous
Install the missing or repair/replace the defective window guard(s) throughout the public areas in accordance with the specifications of the new york city health code section 24 rcny chapter 12.
Oct 5, 2022
Closed — Violation dismissed - CImmediately hazardous
Remove the accumulation of refuse and/or rubbish and maintain in a clean condition the discarded restaurant equipment and supplies stored at rear yard
Oct 5, 2022
Closed — Violation closed
Show 40 more ↓
- BHazardous
Fire egress defective. restore egress by removing locking device and arrange to open readily the gate in fence at lot line ..at rear yard
Oct 5, 2022
Closed — Violation closed - ANon-hazardous
And dept. rules and regulations. scrape and remove rust scales and paint with 2 coats of paint all stories, all balconies and all components at fire escape building front
May 24, 2022
Closed — Violation closed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 1, 2021
Closed — Violation dismissed - ANon-hazardous
§ 300 m/d law file plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration walls erected using wood / studs and sheetrock with door creating storage room under public hall stairs at public hall, 1st story
Feb 11, 2020
Closed — Violation dismissed - ANon-hazardous
Remove device preventing door from being self-closing consisting of kick stopper at vestibule door at public hall, 1st story
Feb 11, 2020
Closed — Violation dismissed - ANon-hazardous
Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper. at public hall, 1st story
Feb 11, 2020
Closed — Violation dismissed - ANon-hazardous
Remove device preventing door from being self-closing consisting of a hook and eye at entrance door to building. at public hall, 1st story
Feb 11, 2020
Closed — Violation dismissed - BHazardous
Replace with new the broken or defective marble tread 4th and 10 up from bottom at public hall stairs, 1st story
Feb 11, 2020
Closed — Violation dismissed - BHazardous
Properly repair with similar material the broken or defective wood floor at public hall, 3rd story
Feb 11, 2020
Closed — Violation dismissed - BHazardous
Properly repair with similar material the broken or defective cermaic floor tiles at public hall, 3rd story
Feb 11, 2020
Closed — Violation dismissed - BHazardous
Properly secure the loose 6th marble tread at the 1st story leading to the 2nd story , ( in between the 1st and 2nd intermediate landings ) at public hall stairs
Nov 4, 2019
Closed — Violation closed - CImmediately hazardous
Abate the infestation consisting of mice in the entire apartment located at apt 17, 4th story, 1st apartment from north at east
Jul 5, 2019 · Apt 17
Closed — Violation closed - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 17, 4th story, 1st apartment from north at east
Jul 5, 2019 · Apt 17
Closed — Violation closed - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color at north wall in the kitchen located at apt 17, 4th story, 1st apartment from north at east
Jul 5, 2019 · Apt 17
Closed — Violation closed - BHazardous
Properly repair with similar material the broken or defective wood floor in the kitchen located at apt 17, 4th story, 1st apartment from north at east
Jul 5, 2019 · Apt 17
Closed — Violation dismissed - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the kitchen located at apt 17, 4th story, 1st apartment from north at east
Jul 5, 2019 · Apt 17
Closed — Violation closed - CImmediately hazardous
Replace with new the broken or defective air valve at radiator at east in the 1st room from north located at apt 13, 4th story, 1st apartment from north at east
Apr 2, 2019 · Apt 13
Closed — Violation dismissed - CImmediately hazardous
Properly secure the loose wood wall cabinet in the kitchen located at apt 13, 4th story, 1st apartment from north at east
Jan 2, 2019 · Apt 13
Closed — Violation dismissed - ANon-hazardous
Replace the broken or defective radiator air vent valve in the 2nd room from north located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Replace with new the missing escutcheon plate at top of riser in the bathroom located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Paint with light colored paint to the satisfaction of this department the ceiling in the private hallway located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Properly repair the source and abate the evidence of a water leak at ceiling in the kitchen located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Paint with light colored paint to the satisfaction of this department the ceiling and all walls in the kitchen located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Replace with new the missing base cabinets at north wall in the kitchen located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Paint with light colored paint to the satisfaction of this department the ceiling and all walls in the 2nd room from north located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Properly repair with similar material the broken or defective wood floor in the kitchen located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Replace the broken or defective radiator air vent valve in the 1st room from north located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Properly repair the source and abate the evidence of a water leak at ceiling in the private hallway located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Paint metal in accordance with dept. regulation the radiator in the 2nd room from north located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Paint with light colored paint to the satisfaction of this department the ceiling in the 1st room from north located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - CImmediately hazardous
Repair the broken or defective plastered surfaces and paint in a uniform color the celing in the bathroom located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Paint with light colored paint to the satisfaction of this department all the walls in the bathroom located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Properly repair the source and abate the evidence of a water leak at ceiling in the bathroom located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Properly repair the broken or defective wood floor in the 1st room from north located at apt 13, 4th story
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Properly repair with similar material the broken or defective wood floor in the private hallway located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - ANon-hazardous
Replace the broken or defective cover for water closet tank in the bathroom located at apt 13, 4th story, 1st apartment from north at east
Nov 26, 2018 · Apt 13
Closed — Violation closed - CImmediately hazardous
Fire escape defective. adjust the dropladder so that it will slide easily in the guide rods .. at 2nd fire escape from east at north
Oct 17, 2014
Closed — Violation dismissed - CImmediately hazardous
Properly secure the loose wood hand rail from intermediate landing to 5th story public hall at public hall stairs
Oct 17, 2014
Closed — Violation closed - BHazardous
Repair or replace the smoke detector defective in the entire apartment located at apt 8, 2nd story, apartment at west
Feb 18, 2014 · Apt 8
Closed — Violation dismissed - BHazardous
Repair or replace the carbon monoxide detecting device(s). missing in the entire apartment located at apt 8, 2nd story, apartment at west
Feb 18, 2014 · Apt 8
Closed — Violation dismissed
DOB building violations · 3
- Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Plumbing none
The dob intends to revoke all approvals and permits under plumbing laa #123203728 due to suspension of master plumbers license. stop all plumbing work under above mentioned permit and obtain a new master plumber to supersede the plumbing permit
Aug 23, 2018
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2013 inspection report
Mar 3, 2015
Dob violation - dismissed
ECB violations · 21
- Class - 1
Unapproved,unsafe,unsuitable,electrical equipment,apparatus devices,appliances or wiring in use.i observed in the main electrical room location in the rear of the commercial restaurant hungry panda exposed,ener
Oct 5, 2022 · Penalty $1,600
Resolve - Class - 2
Unpermitted use of flexible cords as permanent wiring.i observed in the rear of the ground floor restaurant the unpermitted use of extensioncards to supply power to a standing mixer a refrigerator and a deep fr
Oct 5, 2022 · Penalty $800
Resolve - Class - 1
Failure to provide/maintain acess/work space about electical equipmenti observed in the electrical equipment room at the rear of the ground floor restaurant hungry panda the electrical service room with excessi
Oct 5, 2022 · Penalty $1,600
Resolve - Class - 1
28-201.1 inadequate tenant protection plan.note:at time of inspection observed work being performed under aforementioned job number submitted tpp lacks specific means & methods of protecting tenants on health r
Oct 5, 2022
Resolve - Class - 1
Failure to maintain building in code compliant manner.note:at time of inspection observed inside vestibule the wall on the right hand side.the marble slab is pulling off the wall.this is a safety hazard to all
Oct 5, 2022 · Penalty $312
Resolve - Class - 1
Bc3303.10 failure to comply with tenant protection plan.note:at time of inspection observed work being performed under aforementioned job number contractor failed to comply with health requirement section of ta
Oct 5, 2022 · Penalty $2,500
Resolve - Class - 1
Failure to provide proper support for temporary wiring i observed in the residential electric meter room the improper support of a plug-in temp lighting strapped to plumbing piping with zip-ties as per ec code
Oct 5, 2022 · Penalty $1,600
Resolve - Class - 2
Work without permit.work noted:at time of inspection observed three plywood with metal doors storage units approximately 4' deep x 6' wide x8' high installed at rear yard all work 100% completed without permit.
Mar 10, 2020 · Penalty $1,250
Resolve - Class - 2
Work w/o a permit. noted: at the rear yard observed 5 wood shed were erected & installed w/o a permit. dim 6'l x 5'd x 9'h each.(100% of work completed). remedy: obtain all permit.
Oct 27, 2018 · Penalty $1,250
Resolve - Class - 1
Work w/o a permit. noted: erected 2 illuminated signs,each approx 18" high x 5ft long,perpendicular to wall & sticking out across most of the sidewalk at about 10ft above grade. no permit was obtained for this
Mar 13, 2013 · Penalty $800
Resolve
Show 11 more ↓
- Non-hazardous
Having installed and awining without a permit. remedy: remove illegal work.
Feb 10, 2003
Resolve - Non-hazardous
Having installed a sign without a permit. remedy; remove illegal work.
Feb 10, 2003
Resolve - Non-hazardous
Having an illuminated sign without a current permit. remedy: remove illegal work.
Feb 10, 2003
Resolve - Non-hazardous
Having a project sign less than 10 ft above the curb line. remedy: remove illegal work.
Feb 10, 2003
Resolve - Non-hazardous
Having a prohibeted illuminated sign on awning. havign a prohibited illuminated sign in r7-2 district. having a prohibited illuminated sign in window. remedy: remove illegal signage.
Feb 10, 2003
Resolve - Non-hazardous
Residential building having a name plated larger than one sq ft. residential building having more than one nameplace. residential building having a name plae indicating more than the name and address of teh occ
Feb 10, 2003
Resolve - Non-hazardous
Having more than one edentification sign. having an identification sign with an area more than 12 sq ft. remedy: remove illegal sigange.
Feb 10, 2003
Resolve - Non-hazardous
Having more than one sign for each use/ building/ dwelling unit. remedy: remove illegal signage.
Feb 10, 2003
Resolve - Non-hazardous
Having a sign projecting more than 12 inches across the street line. remedy; remove illegal sigange.
Feb 10, 2003
Resolve - Non-hazardous
Having an awning sign indicating more than the name and address of building. remedy: remove illegal signage.
Feb 10, 2003
Resolve - Hazardous
Exit passageway or corridor: total obstructed: fire escapes drop ladder is obstructed by awning and tables and chairs. remedy: remove obstructions.
Feb 10, 2003
Resolve
Complaints
- Heat/hot water
Entire building
Mar 17, 2026 · Apt 10
Close - Unsanitary condition
Pests
Apr 3, 2025 · Apt 2
Close - Unsanitary condition
Pests
Apr 3, 2025 · Apt 2
Close - General
Bell/buzzer/intercom
Nov 8, 2021 · Apt 22
Close - Paint/plaster
Wall
Jun 28, 2019 · Apt 17
Close - Plumbing
Toilet
Apr 8, 2019 · Apt 18
Close - Flooring/stairs
Floor
Nov 20, 2018 · Apt 13
Close - Flooring/stairs
Floor
Nov 20, 2018 · Apt 13
Close - Plumbing
Radiator
Nov 20, 2018 · Apt 13
Close - Water leak
Damp spot
Nov 20, 2018 · Apt 13
Close
Show 40 more ↓
- Flooring/stairs
Floor
Nov 20, 2018 · Apt 13
Close - Paint/plaster
Wall
Nov 20, 2018 · Apt 13
Close - Plumbing
Radiator
Nov 20, 2018 · Apt 13
Close - Water leak
Heavy flow
Nov 20, 2018 · Apt 13
Close - Plumbing
Toilet
Nov 20, 2018 · Apt 13
Close - Paint/plaster
Wall
Nov 20, 2018 · Apt 13
Close - Unsanitary condition
Mold
Nov 20, 2018 · Apt 13
Close - Water leak
Heavy flow
Nov 20, 2018 · Apt 13
Close - General
Cabinet
Nov 20, 2018 · Apt 13
Close - Unsanitary condition
Pests
Oct 20, 2016 · Apt 6
Close - Heat/hot water
Entire building
Feb 6, 2016 · Apt BLDG
Close - Heat/hot water
Entire building
Feb 6, 2016 · Apt 24
Close - Heating
Heat related
Feb 19, 2014 · Apt NA
Close - Heating
Heat related
Feb 19, 2014 · Apt NA
Close - Heating
Heat related
Feb 19, 2014 · Apt NA
Close - Heating
Heat related
Feb 19, 2014 · Apt NA
Close - Heating
Heat related
Feb 19, 2014 · Apt 8
Close - Heating
Heat related
Feb 18, 2014 · Apt NA
Close - Heating
Heat related
Feb 18, 2014 · Apt NA
Close - Heating
Heat related
Feb 18, 2014 · Apt NA
Close - Heating
Heat related
Feb 18, 2014 · Apt NA
Close - Heating
Heat related
Feb 17, 2014 · Apt NA
Close - Heating
Heat related
Feb 17, 2014 · Apt NA
Close - Heating
Heat related
Feb 15, 2014 · Apt 8
Close - Heating
Heat related
Apr 8, 2013 · Apt 1
Close - Heating
Heat related
Apr 8, 2013 · Apt NA
Close - Heating
Heat related
Apr 8, 2013 · Apt NA
Close - Heating
Heat related
Apr 8, 2013 · Apt 5
Close - Heating
Heat related
Apr 7, 2013 · Apt NA
Close - Heating
Heat related
Apr 6, 2013 · Apt NA
Close - Heating
Heat related
Jan 26, 2013 · Apt 1
Close - Heating
Heat related
Oct 19, 2012 · Apt 4
Close - Heating
Heat related
Oct 19, 2012 · Apt 4
Close - Heating
Heat related
Oct 19, 2012 · Apt NA
Close - Heating
Heat related
Oct 18, 2012 · Apt NA
Close - Heating
Heat related
Oct 18, 2012 · Apt 4
Close - Heating
Heat related
Oct 18, 2012 · Apt 4
Close - Heating
Heat related
Oct 18, 2012 · Apt APT1
Close - Heating
Heat related
Oct 18, 2012 · Apt 19
Close - Heating
Heat related
Oct 17, 2012 · Apt 5
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Walk-up apartment building (C7)
- Year built
- 1900
- Floors
- 6
- Residential units
- 24
- Building area
- 16,686 ft²
- Lot area
- 3,542 ft²
- Zoning
- R7-2
- Community board
- 102
- Council district
- 2
- Block / lot
- 543 / 47
- Assessed value
- $3,040,650
- Landmark / historic district
- South Village Historic District
HPD registration #120639, last renewed Jul 17, 2026.
Questions about 140 West 4 Street
Who owns 140 West 4 Street?
The owner of record in NYC Department of City Planning PLUTO data is Keystone 140-142 West Fourth LLC.
Does 140 West 4 Street have violations?
Yes. NYC HPD has recorded 69 housing violations at this property.
Is 140 West 4 Street rent stabilized?
NYC Department of Finance tax bills listed 7 rent-stabilized units here in 2024 (about 29% of its 24 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.
When was 140 West 4 Street built?
City records list 1900 as the year it was built.
How many apartments are in 140 West 4 Street?
It has 24 residential units and 26 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.