roofy

89 Chrystie Street

Manhattan, NY 10002BBL 1-00304-0026Map

Owner of record: Chrystie St Rlty Co

89 Chrystie Street is a garage / gas station built in 1925 in Manhattan, 10002. The owner of record is Chrystie St Rlty Co. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
28
ECB violations
34
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 28

  • Construction other optional

    Full vacate order due to spalled concrete beams and columnswith rebar and spalled/substantially deteriorated concrete slabs withexposed rebar,these conditions,fully vacate the entire parking garage immediately remove all cars.vacate the entire parking garage

    Aug 17, 2023

    Dob violation - active
  • Construction other optional

    Observe several sections missing concrete exposing rebar and steel beams at ever floor. at cellar level 4 steel supports install no

    May 2, 2023

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 23, 2014

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 29, 2014

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 1, 2013

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 19, 2012

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 19, 2012

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Apr 4, 2012

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 21, 2012

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 25, 2012

    Dob violation - dismissed
Show 18 more ↓
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 25, 2012

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 25, 2012

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 24, 2012

    Dob violation - resolved
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2010 inspection/test

    Dec 13, 2011

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 26, 2010

    Dob violation - resolved
  • Elevator annual inspection / test elevatorrequired

    Vcat1-elevator annual inspection / test elevatorrequired

    Oct 8, 2010

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 6, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 21, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 22, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 21, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 17, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    1f1495

    Jun 6, 2002

    Dob violation - resolved
  • Elevator elevatorrequired

    1f1495

    May 17, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    1f1495 cease-use

    Jun 27, 2000

    Dob violation - resolved
  • Elevator elevatoroptional

    1

    Jun 29, 1990

    Dob violation - dismissed
  • Electric signs none

    Es-electric signs none

    Apr 4, 1990

    Dob violation - active
  • Elevator elevatoroptional

    1

    Oct 12, 1989

    Dob violation - dismissed
  • Elevator elevatorrequired

    Restore to service

    Jan 17, 1989

    Dob violation - resolved

ECB violations · 34

  • Class - 1

    Certificate of correction has not been submitted for class 1 violation #37025626n issued 10/11/2023 for failing to submit an engineer's report for structural deficiencies. as of 12/4/2025, no engineer's report

    Dec 4, 2025 · Penalty $6,250

    Active
  • Class - 2

    No access. certificate of correction not obtained for class 1 failure to maintain violation #39085265y issued 5/2/2023 for failure to maintain steel beams, rebar, and supports at cellar level. violation remains

    Dec 4, 2025 · Penalty $1,250

    Active
  • Class - 1

    Unlawful acts. failure to comply with commissioner's order. engineer report requested in dob violation #37025626n has not be submitted as of 10/02/2025., comply with commissioner's order

    Oct 2, 2025 · Penalty $2,500

    Active
  • Class - 1

    Failure to maintain building in a code compliant manner. observed several sections missing concrete exposing rebar and steel beams at ground level., repair and/replace

    Oct 2, 2025 · Penalty $5,000

    Active
  • Class - 1

    Failure to comply with the commissioner's order in dob violation vio23-01273, dated 5/2/2023. respondent was required to submit an engineer's report concerning structurally deficient conditions. as of 10/11/202

    Oct 11, 2023 · Penalty $2,500

    Active
  • Class - 1

    Observe several sections missing concrete exposing rebar and steel beams at ever floor. at cellar level 4 steel supports install no, repair and/replace; repair and/ or replace

    May 2, 2023 · Penalty $1,250

    Active
  • Class - 2

    Failure to comply w/the commissioner's order to file a c/c w/the dob for nov #34981350m issued on 6.19.12 pursuant to 28-204.4 & 1rcny 102-01 for failure to maintain bldg in code compliant manner. all flr(s)

    Jan 10, 2014 · Penalty $800

    Resolve
  • Class - 2

    Work w/o permit. noted: at cellar & 1st fl,floor installed hydraulic car lifts throughout w/o permit or filing. remedy: obtain permit.

    Nov 2, 2013 · Penalty $800

    Active
  • Class - 2

    Failure to maintain: 1) roof exit door sign light/signage 2) cellar fire exit door defective not operating properly & missing exit signage 3) cracking throughout masonry interior walls of front stairway.

    Nov 2, 2013 · Penalty $250

    Resolve
  • Class - 1

    Failure to maintain note: exterior brick rear wall 2nd-3rd flrs, belowfire escape has vertical/horizontal step cracks & missing bricks. rmdy: maintain and repair defect.

    Nov 2, 2013 · Penalty $1,000

    Resolve
Show 24 more ↓
  • Class - 1

    Failure to maintain bldg in code compliant manner. all flrs concrete broken up raised & crack roof spalling. brick walls thru brick verticlecracks. rear fire escape steps broken cellar section collapsed. front

    Jun 19, 2012 · Penalty $1,000

    Active
  • Class - 1

    Work without a permit-cellar level. front cellar temp lolly columus( 12). rear cellar-combination temp lolly columns & set steel columns. rem:obtain permit make safe submit structural engineers report by july

    Jun 19, 2012 · Penalty $1,600

    Active
  • Class - 2

    Failure to comply w/the commissioner's order contained in notice of violation #34933986l issued on 11/3/11. installed shoring/lolly columns below 1st fl as temp support w/o permit. remedy: comply w/the comm's

    Jan 14, 2012 · Penalty $800

    Active
  • Class - 1

    Failure to maintain note: rear fire escape is in(savare) disrepair w/heavy rusting ( ) rotting & (1) step is detached between fls 2-3. remedy: maintain bldg fire escape & make all required repairs.

    Jan 14, 2012 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to maintain exterior building wall(s) or appurtenances. defects noted:at time of inspection fire escape at rear of building has missing steps rusted platforms steps and handrails. stair case at cellar l

    Dec 19, 2011 · Penalty $1,000

    Resolve
  • Class - 2

    Work w/o permit.cellar front-installed 13 lolly columns beams @ top to support flr above cellar rear-installed 3-steel columns(circular)w/ concrete footings.installed 2 lolly columns-w/ wood blank base.immediat

    Nov 3, 2011 · Penalty $800

    Active
  • Class - 1

    Failure to maintain bldg in code compliant manner.on all flrs-flrs cracked broken up & raised.walls interior,thru brick vertical cracks.windows & skylights blocked off(window cmu)(2).rear fire-escape-steps brok

    Nov 3, 2011 · Penalty $1,000

    Active
  • Class - 2

    Failure to comply w/comm's order to file a certificate of correction w/the dob of vio.#34489321z.remedy:comply w/comm's order.

    Nov 3, 2011 · Penalty $800

    Resolve
  • Class - 1

    Failure to maintain bldg in code compliant manner.front stairwell-turnlocks all floor.rear cellar no hardwaky.no exit signs in north stairwell.rem:maintain bldg as per code.

    Nov 3, 2011 · Penalty $1,000

    Resolve
  • Class - 2

    Failure to comply w/comm's order to file a certificate of correcion w/dob for nov#34489322k-issued 10/27/2005."fire exit signs are defective"remedy:comply w/comm's order.

    Nov 3, 2011 · Penalty $800

    Resolve
  • Class - 1

    Rear exit door is totally blocked by a parked vehicle. remedy: remove parked vehicle.

    Oct 3, 2009 · Penalty $800

    Resolve
  • Hazardous

    Cease use 21n10 (21)door lock at "g" bypassed;repair.

    Jun 13, 2006 · Penalty $800

    Resolve
  • Non-hazardous

    21i10/58e01/55y13/51o02/52o02/51i11/40b10/39i10/33r09. (21)repair damaged door lock at street level (58)brake rubbing adjust (55)hoist machine oil leak; clean & seal (51)hoist ropes dirty; clean (52)governor ro

    Apr 4, 2006 · Penalty $180

    Resolve
  • Non-hazardous

    Failure to post the "certificate of occupancy" remedy: post the c of o on site.

    Oct 27, 2005 · Penalty $130

    Active
  • Non-hazardous

    Failure to maintain elevator. hazardous condition noted: 2nd,3rd & roof level operating elevator with the floor doors open. remedy: operate the elevator w/ the doors closed.

    Oct 27, 2005

    Resolve
  • Hazardous

    Fire exit doors total obstruction. fire exit door to stairwell are totally obstructed with parked vehicles this hazardous condition is on roof, 3rd flr 2nd flr & on the 1st flr. remedy: remove all fire door obs

    Oct 27, 2005 · Penalty $480

    Active
  • Non-hazardous

    Fire exit signs are defective all fire exit sign on both the north & south fire doors on the 2nd & 3rd & roof are not illuminated or missingremedy: provide illuminated sings at each fire exit.

    Oct 27, 2005 · Penalty $250

    Active
  • Hazardous

    Failure to maintain building : note spalling & loose concrete with exposed rebar metal @ ceiling in many areas at 1st floor ceiling concreteslab and 2nd floor ceiling slab. remedy : maintain bldg

    Oct 21, 2004 · Penalty $2,000

    Resolve
  • Hazardous

    Failure to maintain bld note: defective, spalling concrete w/exposed rebar below floor slabs throughout. remedy: maintain bld

    Jun 10, 2004 · Penalty $2,000

    Resolve
  • Hazardous

    Failure to maintain bldg note:(1)defective concrete below slabs at-allfloors-with loose concrete,delaminating concrete cracks,spalling and exposed metal rein enforcement and loose sections-throughout garage.(2)

    Feb 25, 2004 · Penalty $800

    Resolve
  • Hazardous

    Required means of egress obstructed.note:(1)rear stairwell is obstructed.at roof rear with locked gate at 3rd flr with car and with locking bar at 1st flr (preventign recentry and exit) (2)front staircase has

    Feb 25, 2004

    Resolve
  • Non-hazardous

    Exit sign defective:note:exit signs throughout garage at stairwells are non-operating not illuminated-defective;remedy:repair and replace signs

    Feb 25, 2004 · Penalty $250

    Resolve
  • Non-hazardous

    15m18r15l50y50y03y62k5m14m 15-hoist door missing in first floor & basement 15-hoist doors blocked open 18-door lock jumped out cease use until items are replace repair call 212-312 -8737 before returning to ser

    May 20, 1998 · Penalty $500

    Resolve
  • Non-hazardous

    15m,18l, (15) & (18) cease use of 1f1495 until all hoistway doors & interlocks are in proper working order

    Jan 28, 1993 · Penalty $500

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Garage / gas station (G1)
Year built
1925
Floors
4
Residential units
—
Building area
17,856 ft²
Lot area
5,724 ft²
Zoning
C6-1G
Community board
103
Council district
1
Block / lot
304 / 26
Assessed value
$1,967,850
Landmark / historic district
No

Questions about 89 Chrystie Street

Who owns 89 Chrystie Street?

The owner of record in NYC Department of City Planning PLUTO data is Chrystie St Rlty Co.

Does 89 Chrystie Street have violations?

NYC HPD has no housing violations on record for this property.

Is 89 Chrystie Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 89 Chrystie Street built?

City records list 1925 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.