165 Bricktown Way
Staten Island, NY 10309BBL 5-07452-0030Map
Owner of record: Unavailable Owner
165 Bricktown Way is a theatre built in 2017 in Staten Island, 10309. The owner of record is Unavailable Owner. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 14
- ECB violations
- 26
- HPD complaints
- 2
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 14
- Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 in 2022
Apr 22, 2023
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 18, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 18, 2019
Dob violation - resolved - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Aug 9, 2018
Dob violation - dismissed - Construction other optional
C-construction other optional
Sep 15, 2017
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Sep 15, 2017
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Sep 15, 2017
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Sep 15, 2017
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Sep 15, 2017
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Sep 15, 2017
Vp*-violation unserved ecb- dismissed
Show 4 more ↓
- Construction other optional
C-construction other optional
Sep 15, 2017
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Sep 15, 2017
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Sep 15, 2017
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Sep 15, 2017
Vp*-violation unserved ecb- dismissed
ECB violations · 26
- Class - 2
Failure to provide approved/accepted construction documents noted: at time of inspection no approved/accepted plan could be found or provided for site fence under permit #520270750-01-eq-fn rmdy: provide appro
Jun 27, 2018 · Penalty $500
Resolve - Class - 2
Job site fence not constructed or maintained pursuant to subsection 3307.7.7 all fence shall be installed, adjusted,repaired and maintained in a sound condition free of protruding or loose nails, wood, or met
Jun 27, 2018
Resolve - Class - 1
3314.1 pswo supported scaffold. scaffold doe snot meet code specifications. noted:at time of inspection workers on scaffold, installing newbrick facade scaffold missing guardrails system pins bricks on scaffol
May 14, 2018 · Penalty $6,250
Resolve - Class - 1
Bc3314.5.platforms on all working levels of scaffold shall be fully planked.noted:at time of inspection working level on scaffold not fully planked.rem:comply with code.
Mar 14, 2018 · Penalty $2,530
Resolve - Class - 1
Bc3314.8.pswo supported scaffold.they open sides and ends of scaffold platforms shall be provided with a guardrail system.noted:at time of inspection workers on scaffold installing brick facade scaffold missing
Mar 14, 2018 · Penalty $6,250
Resolve - Class - 1
Bc3314.5.5.all platforms shall be tied down or otherwise positively restrained.noted:at time of inspection planks are not tied down or positively restrained in multiple locations.rem:comply with code.
Mar 14, 2018 · Penalty $2,530
Resolve - Class - 2
Failure to comply w/the comm's order contained in summons/vio#35294752r issued on 11/27/17 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. fire safety methods were compromised. remedy: comply w/comm's
Jan 12, 2018 · Penalty $2,000
Resolve - Class - 1
Failure to safeguard all persons and property affected by constructionoperation:at the time of inspection it was observed that fire operation was being conducted inadequately.it was observed that flammable prop
Nov 27, 2017 · Penalty $10,000
Resolve - Class - 1
Unlawfully continued work while on notice of a stop work order.noted:continued work finished waterproofing side of bldg from scaffold.i seen2 men on scaffold on sat.11/11/2017 @ 9:42am applying blue waterproofi
Nov 13, 2017 · Penalty $24,000
Resolve - Class - 1
3314.8.2.netting shall be securely attached to the scaffold & shall enclose all open sides,ends bottom of scaffold for full height.noted:menworking on scaffold installing brick facade scaffold over 60 height no
Nov 6, 2017 · Penalty $8,000
Resolve
Show 16 more ↓
- Class - 1
3314.5.5.all platforms shall be tied down or otherwise positively restrained by hooks or equivalent means to prevent dislodgment.noted:@ time of inspection men installing brick facade scaffold over 60 height pl
Nov 6, 2017 · Penalty $8,000
Resolve - Class - 1
3314.8.pswo supported scaffold the open sides & ends of scaffold platforms shall be provided with a guardrail system.noted:@ time of inspection men installing brick facade from scaffold.scaffold missing guardra
Nov 6, 2017 · Penalty $8,000
Resolve - Class - 1
3314.4.3.3.all components of & attachments to the scaffold shall be inspected the results of inspection shall be documented in an installation inspection report signed & dated the scaffold shall not be used unt
Nov 6, 2017 · Penalty $8,000
Resolve - Class - 2
No construction site super log book on site. noticed at time of inspection nb in progress noticed no super log book on site. rmdy: stop all work call best squad.
Sep 15, 2017 · Penalty $400
Resolve - Class - 1
No toe boards. noticed @ time of insp. nb in progress. noticed toe board missing on 2nd fl outer perimeter & around shaftways & open staircase. remedy: stop all work 2nd fl . provide toe boards.
Sep 15, 2017 · Penalty $1,000
Resolve - Class - 2
Bc3314.4.4. materials stored on scaffold while work not in progress. noted approx. 4 pallets of brick stored on scaffold @ rear while no work being performed. remedy: stop all work & remove all bricks from scaf
Sep 15, 2017 · Penalty $400
Resolve - Class - 2
Failure to provide approved plans on site. nb in progress several trades on site no approved plans on site. rmdy: stop all work call best squad.
Sep 15, 2017 · Penalty $250
Resolve - Class - 2
Bc3303.2.2. no permit for fire hydrant use. noticed hose connected to fire hydrant & in use w/o permit for fire hydrant use. remedy: obtain fire hydrant permit.
Sep 15, 2017 · Penalty $400
Resolve - Class - 1
Bc3307.7. failure to provide job site fence. noticed @ time of insp. nb in progress noticed job site fence missing approx. 5 foot pice @ 1 &approx 100 foot of fence @ exp 2. remedy: stop all work & provide fenc
Sep 15, 2017 · Penalty $1,600
Resolve - Class - 2
Bc3307.7.7. job site fence not to code. noticed @ time of insp. nb in progress.noticed job site fence installed throughout site not to code.fence erected is chain link. fence not solid as per code. remedy: stop
Sep 15, 2017 · Penalty $400
Resolve - Class - 1
No guardrails. noted @ time of insp. nb in progress. noted guardrails missing out ground shaf way openings on 2nd fl & mezaanine, open pits on 1st fl one on set back roof @ exp. 3. remedy: stop all work,provide
Sep 15, 2017 · Penalty $1,200
Resolve - Class - 2
Bc3301.1.2.no fdny permit for gasoline & oxigen gas acetylene on site.noticed @ time of insp. nb in progress. noticed approx. 17 gallons of gasoline on site & as well as oxygen & acetylene with no fdny permit.
Sep 15, 2017 · Penalty $400
Resolve - Class - 1
Bc3301.2. inadequate egress. noticed @ time of insp. nb in progress. noticed in ( ) egress to 3rd fl mezzanine ladder is not secured & not extended 3'. egress to scaffold workers climb from mezzanine ont
Sep 15, 2017 · Penalty $1,600
Resolve - Class - 1
Failure to carry out your dukes as a construction site super. the following hazardous conditions observed and fswo issued. no super's log, no guardrails, no toeboards, no approved plans on site, no fence, fenc
Sep 15, 2017 · Penalty $10,000
Resolve - Class - 2
Bc3303.4.1. maintenance all sites shall be free of trip hazards such as standing water. noticed @ time of insp. nb in progress. noticed standing water on 1st & 2nd fl approx. 3" deep & inside the shafway appro
Sep 15, 2017 · Penalty $400
Resolve - Class - 2
Posting of unlawful signs. noticed @ time of insp. unlawful signs posted on job site fence signs advertising construction lumber yard,sign companys & bank, & borough, president signs. remedy: remove unlawful si
Sep 15, 2017 · Penalty $1,200
Resolve
Complaints
- Unsanitary condition
Garbage/recycling storage
Apr 15, 2026 · Apt BLDG
Close - Unsanitary condition
Garbage/recycling storage
Apr 7, 2026 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Theatre (J8)
- Year built
- 2017
- Floors
- 2
- Residential units
- —
- Building area
- 98,683 ft²
- Lot area
- 86,006 ft²
- Zoning
- C4-1
- Community board
- 503
- Council district
- 51
- Block / lot
- 7452 / 30
- Assessed value
- $7,878,150
- Landmark / historic district
- No
Questions about 165 Bricktown Way
Who owns 165 Bricktown Way?
The owner of record in NYC Department of City Planning PLUTO data is Unavailable Owner.
Does 165 Bricktown Way have violations?
NYC HPD has no housing violations on record for this property.
Is 165 Bricktown Way rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 165 Bricktown Way built?
City records list 2017 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.