1060 Willowbrook Road
Staten Island, NY 10314BBL 5-01987-0104Map
Owner of record: NYC Department Of Education
1060 Willowbrook Road is a school building built in 1950 in Staten Island, 10314. The owner of record is NYC Department Of Education. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 11
- ECB violations
- 39
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 11
- Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed
Show 1 more ↓
- Construction other optional
C-construction other optional
May 24, 1996
Dob violation - dismissed
ECB violations · 39
- Class - 2
Re-issue #35692170k. failure to maintain building in code-compliant manner. noted: in room #301, the 2 glas panels at the far eft corner from entry are cracked. remedy: repair/replace.
Feb 26, 2026 · Penalty $3,125
Active - Class - 2
Failure to maintain building in code-compliant manner. illumination for exits and exit discharges and public corridors as per bc 1006.1; 27-381. several emergency lights were not operational when tested. remedy
Feb 26, 2026 · Penalty $1,250
Active - Class - 2
Failure to maintain building in code-compliant manner. noted: there are several exterior exit doors and frames, notably exit #2 and others that are rotted at bottoms of doors and frame legs. further rotting and
Feb 26, 2026 · Penalty $1,250
Active - Class - 2
Failure to maintain building in code-compliant manner. noted: at exposure 1, left of main entry, there is a large tree that is very dried out and brittle. between exit #2 and main entry, adjacent to the flag po
Feb 26, 2026 · Penalty $1,250
Active - Class - 2
Failure to maintain building in code-compliant manner. noted: the retaining wall @ property line outside of exit #7 is leaning and seperating. several inches out of plumb. remedy: repair/replace.
Feb 26, 2026 · Penalty $1,250
Active - Class - 2
Re-issue #35679089r. failure to maintain building in code-compliant manner. noted: at t. o. i. observed the glass in room #301 at the far left corner is cracked. 2 panels of glass are cracked. attention needed
Feb 11, 2025 · Penalty $1,562
Active - Class - 2
Failure to maintain building in code-compliant manner: noted: in room #301, the window in left corner has cracked glass in several panes of that window. remedy: replace/repair the cracked glass.
Sep 17, 2024 · Penalty $625
Active - Class - 2
Failure to maintain building in code compliant manner.observed at t.o.i classroom doors throughout school and others are decorated and/or covered with combustible materials these doors have fire rating.fire rat
May 23, 2022 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. observed at time ofinspection the ceiling of the corridor outside rm#105 is damaged from the water leaking from the condensate(return)pipe in the ceiling. this
May 29, 2020 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. observed at time ofinspection,a drainage pipe that originated in the school yard & then passes through the bldgs basement is cracked at a joint after it enters
May 29, 2020 · Penalty $625
Resolve
Show 29 more ↓
- Class - 2
Reissue ecb 35093200h rotted doors. at cellar, exterior door severely rotted at bottom. at loading dock door, severely rotted at bottom. rmdy: replace doors.
Feb 18, 2015
Resolve - Class - 2
Broken concrete. section of concrete walking broken between music roomand exit 4 outside. rmdy: repair section of concrete.
Feb 18, 2015
Resolve - Class - 2
Spalling plaster. at first flr exits 2,6,7 & 8 have spalling plaster from previous leaks. rmdy: repair spalling plaster.
Feb 18, 2015
Resolve - Class - 2
Failure to maintain bldg in code-compliant manner: interior. at 3rd floor in room 304, hole in wall by entrance door approx 1'x 1' square. remedy: repair or patch hole.
Mar 13, 2014
Resolve - Class - 2
Failure to maintain bldg in code-compliant manner: interior. at 2nd floor,girls bathroom designated 225, wall above sinks cracked & spalling from previous water damage. remedy: repair wall.
Mar 13, 2014
Resolve - Class - 2
Re-issue # 35018326n. failure to maintain bldg: exterior. at cellar, exterior door badly rotted at bottom & at door locking mechanism located at base of loading dock under ash hoist doors outside of interior st
Mar 13, 2014
Resolve - Class - 2
Failure to maintain bldg in code-compliant manner: interior. at 1st floor main lobby,2 roll down gates, no safety stopping in place to prevent gates from rolling down unattended. remedy: provide safety stops fo
Mar 13, 2014
Resolve - Class - 2
At rooftop - chimney flue cap and one exhaust fan hood damaged. fan hood allows water to enter fan, top half of flue cap missing. remedy: maintain/repair bldg.
May 17, 2013
Resolve - Class - 2
Exterior door badly rotted at bottom located at base of loading dock under ash hoist doors outside of interior stair b - cellar level. remedy: maintain bldg.
May 17, 2013
Resolve - Class - 2
At the cellar level failure to provide fresh air ventilation in the gas meter rm. remedy: provide fresh air ventilation in the gas meter rm.
Apr 19, 2011
Resolve - Class - 2
Fail to maintain exterior bldg wall or appurtenances. noted: @ roof wiring to perimeter lighting defective. @ willowbrook side emt broken @ connector. several fixtures have broken/missing insulation or have tem
Apr 22, 2010
Resolve - Class - 3
@ bulkheads a & b plaster is spalled/cracked/missing. remedy: check all bulkheads for moisture damage. repair/replace plaster/paint
Apr 22, 2010
Resolve - Class - 2
Storm water leak @ bulkhead of stair -a- remedy : repair roof / flashing. prevent leak
Aug 9, 2009
Resolve - Class - 2
Approx. 7¬ of concrete pavement missing @ walkway from sunset ave to play yard. remedy: repair / replace concrete
Aug 9, 2009
Resolve - Non-hazardous
Failure to maintain noted cracks and missing piece of concrete exposing reinforceing bar on steps near entrance to schoolyard at s/w corner (uxbridge st) remedy repair steps
Jan 14, 2002
Resolve - Non-hazardous
*reissue* failure to maintain. noted: cap flashing on brick work between windows are loose/pulling away at various locations- particularly outside rm 301 and 315. remedy: repair cap flashing.
Jan 14, 2002
Resolve - Non-hazardous
Failure to maintain *re-issue* noted cracks in brickwork at top n/w corner of exterior wall remedy repair and maintain brickwork
Jan 14, 2002
Resolve - Non-hazardous
Failure to provide emergency light fixture within all stair and corridor on floor 2&3 including stair #1&2 and adjoining corridor on first floor;also vestibule #8&1-failure to provide emergency power to light f
May 30, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:at the south west corner of bldg, the concrete curb is cracked and spalling.remedy:maintain concrete areas make all necessary repairs forthwith.
Apr 5, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:the copper cap flushing outside the windows of rooms #301 and 315 is loose and pulling away.remedy:maintain bldg all necessary repairs forthwith.
Apr 5, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:the parapets have loose and missing mortor joints under the coping stones on the facade side in the following locations:north side behind bulkhead north side near flagpole,north we
Apr 5, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:there is cracked brick and mortor joints and/or loose mortor joints in the following locations:1-the chimney 2-the east bulkhead and 3-the east side parapet.remedy:maintain bldg,ma
Apr 5, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:the crawl space under exit #4/5 is leaking ground water.remedy:maintain bldg make all necessary repairs forthwith.
Apr 5, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:1-the block walls of the stage in the auditorium have cracked block & mortor joints 2- the block walls and plasters in the fan room above the stage have cracked block and mortor jo
Apr 5, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:in the cafeteria the column on the east side middle is cracked.remedy:maintain bldg.make all necessary repairs forthwith.
Apr 5, 2001
Resolve - Non-hazardous
Failure ot maintain: defect is: 1- the bluestone treads at main entry are loose 2-there is no emergency lighting in the stairwells. 3-the west and south side parapet ,have cracked and loose mortor joints . reme
Mar 30, 2000
Resolve - Non-hazardous
Failure to maintain. defect: main entrance steps broken, uneven, trip hazard. chain link fence near playground leaning out of plumb. broken retaining wall falling away. found some cracks at parapet and coping
Jun 9, 1999
Resolve - Hazardous
Failing to provide protection at sides of excavation which has gone beyond 5 ft in depth remedy provide sheeting shoring and bracing and quardrail fence
Oct 4, 1988 · Penalty $500
Resolve - Hazardous
Exit door total obstruction exit door at rear of school in area of excavation for wheel chair ramp has been clocked remedy provide egress.
Oct 4, 1988 · Penalty $500
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- School building (W1)
- Year built
- 1950
- Floors
- 3
- Residential units
- —
- Building area
- 142,888 ft²
- Lot area
- 136,000 ft²
- Zoning
- R3-1
- Community board
- 502
- Council district
- 50
- Block / lot
- 1987 / 104
- Assessed value
- $15,879,600
- Landmark / historic district
- No
Questions about 1060 Willowbrook Road
Who owns 1060 Willowbrook Road?
The owner of record in NYC Department of City Planning PLUTO data is NYC Department Of Education.
Does 1060 Willowbrook Road have violations?
NYC HPD has no housing violations on record for this property.
Is 1060 Willowbrook Road rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 1060 Willowbrook Road built?
City records list 1950 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.