60 Foote Avenue
Staten Island, NY 10301BBL 5-00610-0127Map
Owner of record: NYC Department Of Education
60 Foote Avenue is a school building built in 1954 in Staten Island, 10301. The owner of record is NYC Department Of Education. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 10
- ECB violations
- 47
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 10
- Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed
ECB violations · 47
- Class - 2
Failure to maintain building in code-compliant manner. noted: at t. o.i. observed at exit #4, as viewed from inside, the door at left does not open. excessive force is required to get it open. it's impossible t
Jan 24, 2025 · Penalty $625
Resolve - Class - 2
Reissue35546222h failure to maintain bldg in codecompliant manner.noted:on footeave next to exit5 handrail of top of stairs is missing.repair &/ replace.
May 3, 2022 · Penalty $1,562
Resolve - Class - 2
Exit door not selfclosing noted:on 1fl exit4,door on left isnt closingproperly.repair/replace door.
May 3, 2022 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code compliant manner.observed at t.o.i, the pipe railing at stairs to sidewalk on foote avenue outside exit #5 is missing top rail on both sides of the stairs creating dangerous
May 25, 2021 · Penalty $625
Resolve - Class - 2
B254,50a,50b,50,32a. york shipley moble f.t.s.m blk,lp steam,nb18315s"50a-high pressure steam boiler not officially "de-rated"for low press ure mobile service; 50b-flue gas leakage at front fire door; 50c-no
Apr 10, 2017 · Penalty $500
Active - Class - 2
Rolldown security gates.@ hallways in 1st + 2nd fls.there are rolldown security gates with no safety stop sign.rem:provide safety pins on all roll down interior gates.
Feb 11, 2015
Resolve - Class - 2
Re-issue # 34987291z. failure to maintain bldg: exterior. at roof exterior of exhaust room & blower room, loose & missing mortar & a few cracks on bricks. remedy: repair & repoint brick work.
Mar 25, 2014
Resolve - Class - 2
Failure to maintain bldg in code-compliant manner: interior. at room 116, near rear window wall & ceiling spalling due to previous water damage. remedy: repair wall & ceiling.
Mar 25, 2014
Resolve - Class - 2
Failure to maintain bldg wall(s) or appurtenances: exterior. on martha st side of bldg of staircase b, loose bricks & mortar on facade of staircase. remedy: repair bricks & mortar.
Mar 25, 2014
Resolve - Class - 2
Reissue 34987293m emergency lighting inoperative stair a level b to boiler room. remedy: maintain bldg.
Apr 17, 2013
Resolve
Show 37 more ↓
- Class - 2
Sec. 27-371(b) reissue 34987294y. plexi-glass panels installed on mostclassroom door vision panels throughout school. remedy: comply w/code.
Apr 17, 2013
Resolve - Class - 2
Reissued 34987291z. adjacent rooftop fan room - horizontal crack in mortar above vent. remedy: maintain bldg.
Apr 17, 2013
Resolve - Class - 2
Several vertical cracks, missing concrete in retaining/garde wall under perimeter fence along clove rd. remedy: maintain bldg.
Apr 17, 2013
Resolve - Class - 2
Reissue 34839287l. emergency light in stair to boiler room not working. remedy: repair/replace light.
Aug 2, 2012
Resolve - Class - 2
Cracks in mortar joints of brick work adjacent to blower room or roof.remedy: repair cracks.
Aug 2, 2012
Resolve - Class - 2
Section of flashing detached on low roof of multi-purpose room. remedy: secure flashing.
Aug 2, 2012
Resolve - Class - 2
Sec. 27-371(b) plexi-vision panels installed on most doors throughout bldg. remedy: provide required glass panels.
Aug 2, 2012
Resolve - Class - 2
Ground water penetrating foundation wall @ room b-12 ground water pooling underneath a live bus bar. @ upper level of boiler room ground water penetrating wall beneath chimney. remedy: repair/replace apply wate
Mar 30, 2010
Resolve - Class - 2
Emergency light not working. @ boiler room stair. remedy: ensure that all emergebcy lights have back up
Mar 30, 2010
Resolve - Class - 2
Door check disconnected from frame. noted: many holes from previous attempts to attach *smoke doors - 1st & 2nd flr. remedy: attach door check.
Jun 23, 2009
Resolve - Class - 2
Bc1003.6 27-369 table chairs & other furnishings placed @ stair landing location stair a 2nd fl rem: remove furniture restore designed egress width
Jun 23, 2009
Resolve - Class - 2
Exit door several binding location: exit 12 @ rear of multi purpose room left side standing room rem: re-hang door to ensure of opening
Jun 23, 2009
Resolve - Non-hazardous
Failure to maintain exterior building wall noted one story structure east elevation (multi purpose rm)(1) step crack in brickwork at (sec)door lintel (2) step crack nec shelf angle remedy:repair defects
Jan 12, 2005
Resolve - Non-hazardous
Failure to maintain exterior building wall noted two story structure(1)south elevation sec parapet below coping stone cracked and shifted brickwork (2)south elevation, sec base cracked (vertical)concrete & bric
Jan 12, 2005
Resolve - Non-hazardous
Failure to maintain exterior building wall. noted : roof - chimney / draft vent cracked & open brick and mortar joints. remedy : repair defects
Jan 12, 2005
Resolve - Hazardous
Exit door:total obstruction noted hatch access grate exit along foote avenue obstruction (unable to be opened leading from boiler room.remedy:remove obstruction
Jan 12, 2005
Resolve - Non-hazardous
Failure to maintain bldg interior/exterior.noted:some roof leaks.remedy:maintain bldg
Feb 4, 2004
Resolve - Non-hazardous
Use of illegal hardware lucated @ interior triple doors on 1st fl stair a hasp with padlock present;locked in open position.remedy:remove illegal hardware
Jan 12, 2004
Resolve - Non-hazardous
Failure to maintain exterior building wall defect noted at 1 story portion of section schfold on foote ave side at window lintels level mortar joint defective cracking & loose approx 40ft of mortar joint at no
Jan 12, 2004
Resolve - Non-hazardous
Failure to maintain defect noted at exit stair to front yard exit #2 2stone stair tread are loose & mortar loints cracked, missing causing a trip hazard.remedy:repair defect.
Jan 12, 2004
Resolve - Non-hazardous
Failure to maintain defect noted at rear & side yd wallways pavement has surface defects cracks approx 2'wide drain covers & cleanuuts raised higher than pavement & signs of improper pitch along side of bldg
Jan 12, 2004
Resolve - Non-hazardous
* re - issue * failure to maintain. noted ; fan room on north isde of roof not proivde with louvres for proper venting - ventingoccurs only if entry door is left open. remedy : proivde louvers for proper ven
Jan 18, 2002
Resolve - Non-hazardous
Failure to provide emergency light fixture thin portion of corridor adsoining stair #3 & #4 on floor 1 & 2 inclubing crridor on 2 floor. failure to provide emergency power to light fixture within portion of cor
Jun 21, 2001
Resolve - Non-hazardous
Failure to maintain.defect is the fan room on north side of roof,only vents out if the entry door is open,fan room is for house and toilet exhaust.rem:install wall louvers for proper venting.
Feb 16, 2001
Resolve - Non-hazardous
Failure to maintain.defect is the north south,east and west facades have cracked brick,and craked and loose mortor joints.exit #4 has craked and spalling concrete.rem:repoint facades,and repair exit areas.
Feb 16, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:the chimney has cracked and loose mortor joints.rem:repoint chimney as needed.
Feb 16, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:there is floor tile missing in room #138,and in the teachers lunch room.rem:replace missing floor file.
Feb 16, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:the retaining wall(along clove road)is cracked.rem:repair retaining walls.
Feb 16, 2001
Resolve - Non-hazardous
Failure to maintain.defect is the asphalt surface of the playground,has large cracks.rem:repair the asphalt surface of the playground.
Feb 16, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:the perimeter fence,on the east side of the playground,is missing a gate.rem:replace gate to perimeter fence.
Feb 16, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:1-asphalt surface of the playground has large cracks.2-the retaining wall(along clove rd)is cracked.the facade on the w.&n.sides has cracked mortor joints.4-@entry#3on e.facade
May 17, 2000
Resolve - Non-hazardous
Falure to maintain building interior and exterior. noted minor concrete needed for foundationwalls under fenceing, concrete work at hand cap ramp. playfeild needs some resurfacing and concrete repair, windows h
Jun 3, 1999
Resolve - Hazardous
Failure to maintain parapet wall. around building parapet is cracked at some corners andmasonary has moved projectioning from face of wall. masonry reguires repair and /or pointing. remedy: make necessary repai
Oct 5, 1995 · Penalty $1,000
Resolve - Non-hazardous
Operation of a place of aswsmbly without a current permit. remedy: obtain permit for gym cafeteria
Apr 12, 1995
Resolve - Hazardous
Failure to have approved public assembly plans available for inspection remedy provide approved plans
Oct 25, 1993 · Penalty $50
Resolve - Hazardous
Operation of a place of assembly without a current pa.permit.remedy: obtain permit. failure to have approved pa.plans available on premisesfor inspection. remedy:provide approved plans.
Jul 12, 1991 · Penalty $650
Resolve - Hazardous
Operation of place of assembly without acurrent permit remedyu obtain permit failure to have approved pa plans available for inspection remedy provide approved paland. no emergency lighting in gym cafeteria
Aug 17, 1988 · Penalty $1,525
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- School building (W1)
- Year built
- 1954
- Floors
- 2
- Residential units
- —
- Building area
- 24,500 ft²
- Lot area
- 135,000 ft²
- Zoning
- R3-2
- Community board
- 501
- Council district
- 49
- Block / lot
- 610 / 127
- Assessed value
- $4,057,200
- Landmark / historic district
- No
Questions about 60 Foote Avenue
Who owns 60 Foote Avenue?
The owner of record in NYC Department of City Planning PLUTO data is NYC Department Of Education.
Does 60 Foote Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 60 Foote Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 60 Foote Avenue built?
City records list 1954 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.