165-15 Archer Avenue
Queens, NY 11433BBL 4-10155-0029Map
Owner of record: Berken Building Co
165-15 Archer Avenue is an office building built in 1973 in Queens, 11433. The owner of record is Berken Building Co. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 54
- ECB violations
- 23
- HPD complaints
- 2
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 54
- Construction other optional
Engineers report required due to separation at intersection of wall and support column of 5th floor office space.
Feb 12, 2026
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 23, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 23, 2021
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 11, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 11, 2019
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 18, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 18, 2017
Dob violation - resolved
Show 40 more ↓
- Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 3, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 3, 2016
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2012 inspection/test
Mar 31, 2014
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2012 inspection/test
Mar 31, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 16, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 16, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 15, 2012
Dob violation - resolved - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Jan 1, 2012
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 25, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 25, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 30, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 30, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 18, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 18, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 9, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 9, 2007
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 19, 2007
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 26, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 26, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 24, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 24, 2006
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 6, 2006
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 2, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 2, 2005
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 31, 2005
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 31, 2004
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 31, 2004
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 19, 2003
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 14, 2001
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 14, 2001
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 10, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 10, 1997
Dob violation - dismissed
ECB violations · 23
- Class - 2
In response to fdny's request for sws inspection research shows sidewalk shed permit under application q01223236 is expired creating unsafe conditions to the public and property due to daily inspections not bei
Jul 10, 2026 · Penalty $625
Resolve - Class - 2
At time of inspection observed vertical members of sidewalk shed at vehicular access point not additionally braced or marked with hi visibility markings to prevent dislodgment in the event of being struck by ve
Jul 10, 2026 · Penalty $2,400
Resolve - Class - 2
Missing parapet info panel creating hazardous conditions to the public and emergency services attempting to locate the building.provide and maintain parapet info panel
Jul 10, 2026
Resolve - Class - 1
At time of inspection observed separation at intersection of wall and support column of 5th floor office space. also facade in state of disrepair with spalling/cracked masonry at 5th sty level of exp.3 (rear of
Feb 12, 2026 · Penalty $2,500
Active - Class - 1
No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which ensures passenger safety. remedy; file application, install dlm a
Mar 10, 2021 · Penalty $1,250
Resolve - Class - 1
No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which ensures passenger safety. remedy; file application, install dlm a
Mar 10, 2021 · Penalty $1,250
Resolve - Class - 2
Found rockmills boiler model-mp100 ser#91157 active with defects. missing spilling switch on barometric damper. lights in boiler room not working. debris in boiler room. correct all violating conditions and sub
Sep 24, 2020
Resolve - Class - 2
52k2,53k2,59bb5,67d10. 52k2-clean and monitor rusted hoist ropes; 53k2-clean and monitor rusted governor rope; 59bb5-brake tag expired on 1/26/17; 67b10-in ar phone needs to be reprogrammed.
Oct 17, 2018 · Penalty $625
Resolve - Class - 2
59bb5,67b10. 59bb5-brake tag expired on 01/26/17; 67b10-in car phone needs to be reprogrammed.
Oct 17, 2018 · Penalty $625
Resolve - Class - 2
99b7:current one year test;expd tag-provide
Sep 13, 2017 · Penalty $1,250
Resolve
Show 13 more ↓
- Class - 2
99bb7
Sep 13, 2017 · Penalty $1,250
Resolve - Class - 2
Failure to maintain bldg in code compliant manner.use of prohibited door &/or hardware per bc1008.1.8; 27-371(j). noted @ room #3 for a/c midle door is defective & rm #4 exit door to playground door & hardware
Jul 5, 2017 · Penalty $250
Resolve - Class - 2
Failure to file annual certification that cooling tower 1000004895 hasbeen inspected,tested,& disinfected,& that a maintenance plan has beendeveloped & implemented by 11/1/16. remedy: file annual certification.
Jun 20, 2017 · Penalty $2,000
Resolve - Class - 2
98bb05.10m07.14m07.58l10.58l10 one of the machine bearings very noisy
Jan 16, 2009 · Penalty $2,500
Resolve - Non-hazardous
10h11.17h11.25d06.03x10.59x10.84x10.55b10.21e01. 03 fan inoperative 84emergency 2 way communication 55-machine noise 21-interlocks rubbing up against door clutch
May 2, 2008 · Penalty $2,500
Resolve - Non-hazardous
17h11.25d06.59x10.39#10. 39-repair outlet in machine room
May 2, 2008 · Penalty $2,500
Resolve - Hazardous
Failure to maintain. defect is: at roof sheet metal duct for wirless antenea cover for duct is not secured and flapping in the wind approx 2'wx12'l section loose creating a hazardous condition. remedy: repair o
Nov 21, 2002 · Penalty $2,500
Resolve - Non-hazardous
3o,4x,8v,16m, (3)- clean top of car. (4)- provide keys for door. (16)- 2nd & 5th floor.
Apr 7, 1992
Resolve - Non-hazardous
3o,4x,8j, (3)- clean top of car. (4)- provide keys for door.
Apr 7, 1992 · Penalty $1,000
Resolve - Non-hazardous
73 # 5, 30 o 2, 58 o 2 59 o 2 10 l 11 25 l 1 52 l 1
Apr 30, 1991
Resolve - Non-hazardous
73 # 5, 30 o 2, 58 o 2, 59 o 2, 9 m 10
Apr 3, 1991
Resolve - Non-hazardous
74#05,10l11,73o02. (74) conduct a 5 year test and file elv3. (10) door close button.
Nov 9, 1990
Resolve - Non-hazardous
25l11,74#05,73o02. (74) conduct a 5 year test and file form elv3.
Nov 9, 1990
Resolve
Complaints
- Heat/hot water
Entire building
Feb 9, 2026 · Apt BLDG
Close - General
Signage missing
May 27, 2022 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Office building (O2)
- Year built
- 1973
- Floors
- 5
- Residential units
- —
- Building area
- 78,800 ft²
- Lot area
- 24,628 ft²
- Zoning
- C6-2
- Community board
- 412
- Council district
- 27
- Block / lot
- 10155 / 29
- Assessed value
- $8,949,150
- Landmark / historic district
- No
Questions about 165-15 Archer Avenue
Who owns 165-15 Archer Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Berken Building Co.
Does 165-15 Archer Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 165-15 Archer Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 165-15 Archer Avenue built?
City records list 1973 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.