roofy

97-11 Sutphin Boulevard

Queens, NY 11435BBL 4-10031-0010Map

Owner of record: Aih Group, LLC

97-11 Sutphin Boulevard is a hotel built in 2018 in Queens, 11435. The owner of record is Aih Group, LLC. HPD has recorded 2 housing violations here, most recently on November 21, 2025.

HPD violations
2
DOB violations
32
ECB violations
63
HPD complaints
1

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Nov 21, 2025

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 2

  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 21, 2025

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Jun 16, 2025

    Closed — Violation dismissed

DOB building violations · 32

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 5, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 10, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 2, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 2, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 2, 2020

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Aug 19, 2020

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Feb 2, 2020

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Nov 2, 2019

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2019

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2019

    Dob violation - dismissed
Show 22 more ↓
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Apr 17, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Apr 17, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Apr 17, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Apr 17, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Apr 17, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 25, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 25, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 25, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 25, 2018

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2015 inspection report

    Feb 24, 2017

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2011 inspection report

    Mar 1, 2013

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2010 inspection report

    Dec 13, 2011

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Lblvio-low pressure boiler boiler required

    Dec 31, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 1, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 19, 2007

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 19, 2003

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 7, 2000

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 10, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 29, 1995

    Dob violation - dismissed

ECB violations · 63

  • Class - 2

    Time of inspection observed 9 story new building interior work in progress, pswo exists . upon request to see cs daily logs and weekly tool boxtalk the cp provide the cs log books, it was missing logs from 6/1

    Jun 5, 2023

    Resolve
  • Class - 1

    Failure to maintain elevator/hoist in state of readiness/expired certificate for fdny use bc 3303.12.2(1)+3009.3.@active 9story nb site observe & per dob records, only 1 elevator (device#4p0995008) in place for

    Jun 1, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    @active 9 story nb site observe standpipe system up to 9th-roof level approx. 80-88ft in height from grade level with no records of hydrostatic test performed in dob records&no evidence of testing provided by s

    Jun 1, 2023 · Penalty $5,000

    Resolve
  • Class - 2

    At time of inspection on active 9 stories nb jobsite under construction, i observed in place at exp#-1 on sutphin blvd with material storage zone used as car park purposes and not maintained as per dot regulati

    Oct 18, 2022 · Penalty $625

    Resolve
  • Class - 2

    At time of inspection on active 9 stories nb jobsite, i observed in place at exp#-1 with installed plywood fence/ mesh screen on sidewalk. upon request for dot permit for maintain fence as per dot regulations,

    Oct 18, 2022 · Penalty $625

    Resolve
  • Class - 2

    At time of inspection on active 9 stories nb jobsite under construction, i observed at exp#-1 on sutphin blvd with installed yuddocks/ barriers in place for storage zone on street not in accordance with manufac

    Oct 18, 2022 · Penalty $625

    Resolve
  • Class - 1

    Unsafe platform bc3315.2.@9 story nb site observe temporary platform over elevator shaft opening at roof level unsafe and not to codes exposing workers/people to hazards of fall and below platform to falling ob

    Oct 12, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Supported scaffold bc3314.1+@9 story nb site observe supported scaffold in place throughout up to roof level in unsafe conditions-platform not full deck and planks not tied down,inadequate/missing guardrail sys

    Oct 12, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    At time of inspection the material storage work zone safeguards were inadequate. i observed that the yodock's were knocked down, not interlocked and not filled as per manufactures specifications to prevent easy

    Oct 1, 2022 · Penalty $6,250

    Resolve
  • Class - 1

    At time of inspection of a 9 story building with no active construction going on, i called out and knocked on the door and fence to see if there was a watchperson onsite and no one appeared. as per code when a

    Oct 1, 2022 · Penalty $2,500

    Resolve
Show 40 more ↓
  • Class - 2

    7 fl makeshift p.form supporting ladders leading to 8fl of 4 inchx4inch wood timber joist supported by 2inchx4inch wood stud beam w/2inchx4inch wood vert members,plywood top w/water proofing,platform reducing f

    Aug 27, 2022 · Penalty $3,125

    Resolve
  • Class - 1

    New building active job site at 9th floor level. competent person is presented required documents. they are doing material placement and housekeeping work. no debris is found. they use boom truck on street fo

    Aug 22, 2022 · Penalty $6,250

    Resolve
  • Class - 2

    3301.2 guardrails missing midrails.at the time of my inspection at a 9story new building active site,i observed supported scaffold missing midrails and not fully planted at various locations.stop all use of sup

    Jun 24, 2022 · Penalty $625

    Resolve
  • Class - 1

    Yodocks manufacturer specification.note:at the time of my inspection,iobserved that the yodocks at exp.#1 were open,unlocked,unfilled & scattered in the street.as per manufacturer specifications the yodocks mus

    Apr 8, 2022 · Penalty $2,500

    Resolve
  • Class - 2

    Fence not maintained.note:at the time of my inspection i observed thatthe construction fence at 97-11 sutphin blvd exp.#3 was dislodged broken & leaning,& could fall ito the pedestrian walkway.the lack of daily

    Apr 8, 2022 · Penalty $1,000

    Resolve
  • Class - 1

    Unlawfully continued work while on notices of stop work orders.at timeof inspection in response to complaint on a 9 story nb site w/2 partial stop work orders in effect.complaint #s 4874832 & 4875496 both comme

    Apr 1, 2022 · Penalty $5,000

    Resolve
  • Class - 1

    Bc3314.1 supported scf not comply w/codes atoi in response to complaint on active 9stynb site i observe supported scf up to 9fl level thruout perimeter of site&secs not to codes note:(1)debris netting loose/mis

    Mar 29, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to provide standpipe in state of readiness for fdny first responders.atoi on active 9stynb site.i observed concrete working deck forpoured 9fl in place&discovered on provided plans&submitted docs to dob

    Mar 29, 2022 · Penalty $5,000

    Resolve
  • Class - 1

    Bc 3303.12 temporary elevation on hoist during construction or demolition. note:at the time of my inspection of a 9 story building at 8 fl,iobserved 5 worker on site. upon walking site there were 2 work at 7 an

    Mar 21, 2022 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to perform proper concrete washout water procedures. at time of inspection observed concrete pour in progress where drawings for washout provided but not used. concrete has leeched into street and sewer

    Jan 6, 2022 · Penalty $5,000

    Resolve
  • Class - 2

    Work does not conform to approved construction documents.as noted at time of inspection at an active jobsite,observed form work erected for columns and shear walls supporting fifth floor slab.observed after rev

    Oct 15, 2021 · Penalty $3,125

    Resolve
  • Class - 2

    Failure to safety equipment measure-no ohp noted:at the time of my inspection 9 story new building at 5th floor level under construction.i observed no overhead protection provided at exp-2 front side for adjace

    Oct 14, 2021 · Penalty $5,000

    Resolve
  • Class - 1

    Work doesnt conform to approved const doc ato my insp of 9stynb jobsite i observed (illegible) beam installation on 2fl contrary to approvedplan (illegible) horiz bracing of bolts&heavey (illegible) shoring pos

    Oct 5, 2021 · Penalty $6,250

    Resolve
  • Class - 1

    Failure to comply with manufactures specification.at the time of my inspection of a 9 story nb jobsite i observed that the site is closed.i observed at exp 1 storage area,vodock barriers not connected & not fil

    Aug 10, 2021 · Penalty $6,250

    Resolve
  • Class - 2

    Failure to provide sws info panel.@time of my insp of new proposed 9stybldg i observed sws erected not to code.sws missing info panel on parapet.this creates hazard situation in case of emergency for 1st respon

    May 22, 2021

    Resolve
  • Class - 2

    Failure to provide pedestrian protection.@time of my insp of proposed 9stynb@4fl level.i noticed that sws doesnt meet code requirements.as per sec (3307.6.2-3307.6.3) sws shall be extended full l of sidewalk@ex

    May 22, 2021 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to maintain adequate housekeeping per sec requirement.note:@time of my insp of active jobsite,9stynb jobsite.i observed tremendous amy of debris,scrap of bldg material piled up@exp3 creating temp/full h

    Apr 21, 2021 · Penalty $625

    Resolve
  • Class - 2

    Failure to safeguard all persons&property affected by const operations.@time of my insp on active 9sty jobsite@4fl level,i observed concrete(illegible) spilled on roadway by sidewalk creating hazardous conditio

    Apr 21, 2021 · Penalty $5,000

    Resolve
  • Class - 2

    3308.5 guardrail netting @time of my insp of active 9sty jobsite,i observed missing netting on [email protected] guardrail netting constitutes safety hazard of material (illegible).stop all const elemen

    Apr 21, 2021

    Resolve
  • Class - 1

    Failure to file evidence of compliance with workers comp.law and/or disability benefits law.note:at time of my inspection of a 9 story new building at 4th floor level under construction.construction superintend

    Mar 22, 2021 · Penalty $5,000

    Resolve
  • Class - 2

    Housekeeping.note:at time of inspection of a 9 story new building at 4th floor level under construction.i observed 4th floor level construction materials debris throughout on rebar not provide adequate or secur

    Mar 22, 2021

    Resolve
  • Class - 2

    Bc 3301.7 failure to provide p.e approved design drawings. as noted:attime of inspection on a construction site,observed in multiple areas in cellar fl concrete walls w/ exposed rebar,significant honeycombing.

    Feb 8, 2021 · Penalty $620

    Resolve
  • Class - 1

    Manufactor specifications. note: at the time of my inspection of an 9 sty,i observed a yodock system was inadequate(&)manafacture spec,yodock system,didnt have water nor sand. yodock system must be filled with

    Jan 5, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to safeguard all person & property affected by construction. note: at the time of my inspection of an 9 sty bldg at 3 floor level w/construction work in progress. i observed at exp#4 neighboring propert

    Jan 5, 2021 · Penalty $10,000

    Resolve
  • Class - 1

    Sec. 3309.2 license to enter adjoining property. note: at the time of my inspection of a 9 sty bldg w/construction work in progress. i observed access agreement for construction site to protect neighboring prop

    Jan 5, 2021 · Penalty $625

    Resolve
  • Class - 1

    Sec. 3301.6.1 detail drawing design. note: at the time of my inspection of a 9 sty bldg w/construction work in place,i observed at exp#2 an steel stair installed w/anchor bolts drawing of install with bolts in

    Jan 5, 2021 · Penalty $625

    Resolve
  • Class - 1

    3307.4-work and storage zone note at the time of my inspection responding to an acomplaint of a 9 story building at 3 flooor level with construction work in progress i observed work and storage zone at exposure

    Dec 7, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Bc 3301.2 failure to safeguard public and property as per code,no overhead protection. at time of inspection on an active 9 story nb construction site notice that the contractor fail to maintain protection for

    Sep 2, 2020 · Penalty $6,250

    Resolve
  • Class - 2

    Failure to safeguard public & property-no overhead protection. at timeof inspection of a 9 sty nb currently at 3rd fl i observed no overheadprotection provided for adjacent property front parking lot at exp#2

    Jun 30, 2020 · Penalty $5,000

    Resolve
  • Class - 1

    Bc 3309.10 inadequate roof protection(exposure#4)in response to above mentioned complaint#4811993,observed inactive jobsite.neighboring bodyshop expressed complaints to me regarding tripping hazards at roof lev

    May 27, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Permit holder failed to ensure worker attend pre-shift safety meeting.note at the time of my inspection of an 9 story building on the third floor with work in progress that consist of carpentry.upon request for

    May 22, 2020 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by construction operations. at time of inspection observed entry & exit to 3rd level where workers are laying decking forms no fall protection at interior

    May 21, 2020 · Penalty $10,000

    Resolve
  • Class - 1

    Sec. 3301.2 uncapped rebar failure to maintain. at time of my inspection observed active jobsiute. uncapped rebar has been found at 2nd fl level was not maintain as required. 2 workers was working at 2nd floor

    May 20, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    3309.10 protection of roof failure to maintain of time of my inspection of a 9 story new building of 2nd floor level under construction.i observed expl-4 adjacent property roof was not provided protection as re

    Mar 14, 2020 · Penalty $2,500

    Resolve
  • Class - 2

    Work after hours without a variance permit contrary to 28-105.12.5 note:at time of my inspection of a 2 story new building at 1st floor level under construction.i observed over 20 workers was working for rebar

    Mar 14, 2020 · Penalty $3,125

    Resolve
  • Class - 1

    Failure to provide osha training @time of inspection on an active job site owner failed to ensure each worker working/engaged @the site successfully completion the required training under bc 3321.1 & has an osh

    Mar 12, 2020 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to provide osha training @the time of my inspection on a active jobsite permit holder failed to ensure each worker/(evaluated) @the site success fully completed the required training under bc 3321.1 &

    Mar 12, 2020 · Penalty $5,000

    Resolve
  • Class - 1

    Filed a cert form, application etc a material of false statement(s).noted: respondent filed asigned pw-2 work permit application for apllication #420665462 & agreed to the statement in section 12" i hereby stat

    Mar 12, 2020 · Penalty $5,000

    Resolve
  • Class - 2

    Pedestrian protection does not meet code specifications sidewalk shed has no light. note: @time of my inspection of a 9 sty buildig @1st fl level under const work in progress. i observed that the side walk shed

    Dec 5, 2019 · Penalty $2,400

    Resolve
  • Class - 2

    Pedestrian protection does not meet code code specification sidewlak shed no light at time of my inspection observed none active job site th e sidewalk shed light was not on during my inspection at 4:45am as re

    Jul 9, 2019 · Penalty $5,000

    Resolve

Complaints

  • Unsanitary condition

    Garbage/recycling storage

    Oct 15, 2022 · Apt BLDG

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Hotel (H3)
Year built
2018
Floors
9
Residential units
—
Building area
36,389 ft²
Lot area
9,060 ft²
Zoning
C6-2A
Community board
412
Council district
27
Block / lot
10031 / 10
Assessed value
$4,264,650
Landmark / historic district
No

HPD registration #434487, last renewed Nov 25, 2025.

Questions about 97-11 Sutphin Boulevard

Who owns 97-11 Sutphin Boulevard?

The owner of record in NYC Department of City Planning PLUTO data is Aih Group, LLC.

Does 97-11 Sutphin Boulevard have violations?

Yes. NYC HPD has recorded 2 housing violations at this property.

Is 97-11 Sutphin Boulevard rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 97-11 Sutphin Boulevard built?

City records list 2018 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.