roofy

121-15 101 Avenue

Queens, NY 11419BBL 4-09461-0027Map

Owner of record: Maha Lakshmi Mandirinc

121-15 101 Avenue is a religious facility built in 1930 in Queens, 11419. The owner of record is Maha Lakshmi Mandirinc. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
3
ECB violations
35
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 3

  • Construction other optional

    The applicant of record has informed the department that she or he has withdrawn from the project. therefore, the application fails to set forth the full name, address, telephone number, email address of the applicant in violation of section 28-104.8.3. until such information is provided to the department,

    Nov 17, 2025

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 23, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 15, 2017

    Dob violation - dismissed

ECB violations · 35

  • Class - 2

    Observation: @ expo#1 sidewalk shed permit#q00557944-i1-sh expired 0n 12/28/2024. vio for expired temporary (sws) construction equipment permit.renew permit

    Apr 21, 2025 · Penalty $6,250

    Active
  • Class - 2

    At time of inspection, i observed sidewalk shed at exposure #1 permit was expired on 12-28-2024 upon reviewing bis / dobnow.

    Mar 21, 2025 · Penalty $6,250

    Active
  • Class - 2

    At time of inspection i observed a 3 story alt building. upon research on bis and dob now observed no active construction fence permit. fence permit needs to be active at all timesobtain a construction fence pe

    Mar 17, 2025 · Penalty $6,250

    Active
  • Class - 2

    At time of inspection observed a 3 story alteration building. upon research on bis and dob now observed no active construction fence permit.fence permit needs to be active at all times. obtain construction fenc

    Dec 17, 2024

    Resolve
  • Class - 2

    During inspection of at proposed 3 story building, i observed 5:20 am that the sidewalk shed in place had no lights illuminating under the shed. there were light bulbs installed but they were not on as required

    Oct 21, 2024

    Resolve
  • Class - 1

    During inspection of a proposed 3 story building with structural steel beams in place from the 1st and 2nd story, all work was done without a permit for the new build/alteration, the site never had a permit iss

    Oct 21, 2024

    Resolve
  • Class - 2

    During inspection of a proposed 3 story building, i observed at 5:20 am the sidewalk shed in place had no lights illuminating under the shed. there were light bulbs installed but they were not on as required fr

    Oct 21, 2024 · Penalty $10,000

    Active
  • Class - 2

    At the time of my inspection after checking approved plan for temporary bracings of freestanding wall i observed 3 temporary bracing removed from free standing wall at exp#2-and 1 bracing missing bolts at foot

    May 3, 2024

    Resolve
  • Class - 2

    At the time of my inspection observed temporary working platform(planks/plywood,2by4) on opening for stairway going from 1st floor to basement(no stairs installed) aprox 10feet deep-uppon asking for design draw

    May 3, 2024 · Penalty $3,125

    Resolve
  • Class - 2

    At the time of my inspection of active site uppon asking for orientation training log/documentation for 4 workers on site -none were provided

    May 3, 2024 · Penalty $3,125

    Resolve
Show 25 more ↓
  • Class - 2

    At the time of my inspection after reviewing sidewalk shed drawings i observed sidewalk shed at exp#1 installed contrary to plans-installed 14 feet high shed not shown on plans, spacing between posts 15 feet n

    May 3, 2024 · Penalty $3,125

    Resolve
  • Class - 1

    Work does not conform to construction documents and/or amended plan. at time of inspection observed demolition work exceed proposed work. plan does not indicate removal exposure 1 and 2 exterior walls for one s

    Apr 17, 2024 · Penalty $6,250

    Resolve
  • Class - 2

    General contractor has failed to act in a reasonable and responsible manner for site construction safety as per bc 3301.1.1: at inspection it was observed personnel working at the leading edge of excavation at

    Feb 9, 2024 · Penalty $5,000

    Resolve
  • Class - 2

    At inspection, it was observed: as per soe-402.00 and ssp-406.00 approved plans, work is contrary- lagging boards outside of steel pile at exp.4,soe wobbling at exp.1&2,short in height(not to the edge of grade)

    Feb 9, 2024

    Resolve
  • Class - 2

    At inspection, it was observed: upon request for pre-construction survey of adjacent property at exposure-2 with monitoring locations observed none was available/presented, also no record of 3rd party inspector

    Feb 9, 2024 · Penalty $1,250

    Resolve
  • Class - 2

    At inspection, it was observed: personnel at the leading edge of excavation at exposure-2 without any form of protection at the edges of excavation and no ppe on the personnel to prevent falling in to a depth o

    Feb 9, 2024 · Penalty $5,000

    Resolve
  • Class - 2

    No parapet/ construction sign present at the time of inspectioncomply with code

    Oct 17, 2023 · Penalty $1,280

    Resolve
  • Class - 2

    Sws permit #q00557944 expired 7/14/2023comply with code

    Oct 17, 2023 · Penalty $1,280

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#35287399j issued on 08-14-17 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. no c of c filed. remedy: comply w/comm's order &/or file a c of

    Jun 4, 2019 · Penalty $3,125

    Resolve
  • Class - 2

    Failure to comply w/ the commissioner's order contained in summons/violation#35287399j issued on 8/14/17 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01. for work w/o a permit. rem

    Mar 29, 2019 · Penalty $3,125

    Resolve
  • Class - 1

    Failure to comply w/ the commissioner's order contained in summons/violation#35287399j issued on 8/14/17 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01. erected metal shed approx.

    Feb 9, 2019 · Penalty $12,500

    Resolve
  • Class - 2

    Failure to comply w/ the commissioner's order contained in summons/violation#35287399j issued on 8/14/17 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01. at front, erected metal sh

    Dec 7, 2018 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#35287399j issued on 08-14-17 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. work w/o a permit. remedy: comply w/comm's order &/or file a c

    Oct 12, 2018 · Penalty $1,250

    Resolve
  • Class - 1

    Wokr w/o a permit. observed ground level converted a church(matal)awning or storm enclosure covering whole bldg. electrical wiring work donefor high this sheed is 22feet high from ground level-inside found 1 ca

    Aug 14, 2017 · Penalty $4,000

    Resolve
  • Class - 2

    Failure to comply w/the comm's order to file a c of o w/the dob's for nov #34774867n & 34880483n for illegal erection of steel structured shed at right side (exposure 4). no filing in dob's record for the struc

    Nov 7, 2012 · Penalty $2,000

    Resolve
  • Class - 2

    Failure to comply w/ the comm's order to file a cert of correction w/ the dob.noted:the metal shed @ right side as per nov#34774867n still exists.no job filing @ dob record to correct the violations.rem:file ce

    Jan 18, 2011 · Penalty $800

    Resolve
  • Class - 2

    Failure to maintain building walls or appurtenances. noted: at the right side steal frame shed approx 40'w x 80'd x 14'h installed gutter & leaders open to grade level allowing rain water drainage to street &

    Jul 23, 2010 · Penalty $500

    Resolve
  • Class - 2

    Sec. zr 24-35 misc violations of zoning resolution. noted: erected steel framed open shed/canopy covering entire right side parking yard approx 40'w x 80'd x 14'h with steel tube columns & trust & metal sheets

    Jul 23, 2010 · Penalty $800

    Resolve
  • Class - 2

    Occupancy contrary to that allowed by the certificate of occupancy. c/o #400507439 states off street parking(osp) for accessory parking for 15 cars.at time of inspection parking lot now set up for occupancy wit

    Jun 3, 2010 · Penalty $1,200

    Resolve
  • Class - 2

    Work without a permit.noted:in parking lot a wood frame stage area hasbeen erected as well as a wood frame gazebo.no permits on file for th e work performed.obtain permit or remove structures.

    Jun 3, 2010 · Penalty $800

    Resolve
  • Class - 1

    28-207.3 public nuisance: noted-8ft high chain link fence at exposure 1 has razor wire looping around top rail of in a way where it is easily accessable to public and can cause serious injury. maintain building

    Jun 3, 2010 · Penalty $1,600

    Resolve
  • Class - 2

    Fail to comply w.comm order to file a certificate of correction w.dob noted: erected metal shed 13'h x 30'w x 50'd at sideyard still exists via nov 34774867n. remedy: file certificate of correction

    Jun 2, 2010 · Penalty $800

    Resolve
  • Class - 2

    Work without a permit. note: construction of metal shed approx 13 ft high 30 ft wide 50 deep at side yard east. rem: obtain a permit or submit proof of permit.

    May 18, 2009 · Penalty $800

    Resolve
  • Class - 2

    Approved place of assembly plans not available for inspection. remedy:provide approved approved place of assembly plans.

    Apr 29, 2009 · Penalty $500

    Resolve
  • Class - 2

    Fail to maintain exterior. noted: 8'high chain link fence approx 40'w x 100'l with constina barb wire long top. remedy: comply with code.

    Apr 29, 2009 · Penalty $500

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Religious facility (M1)
Year built
1930
Floors
2
Residential units
—
Building area
11,940 ft²
Lot area
7,569 ft²
Zoning
R6B
Community board
409
Council district
29
Block / lot
9461 / 27
Assessed value
$402,750
Landmark / historic district
No

Questions about 121-15 101 Avenue

Who owns 121-15 101 Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Maha Lakshmi Mandirinc.

Does 121-15 101 Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 121-15 101 Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 121-15 101 Avenue built?

City records list 1930 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.