87-40 124 Street
Queens, NY 11418BBL 4-09332-0026Map
Owner of record: Lakshmi LLC
87-40 124 Street is a walk-up apartment building built in 2022 in Queens, 11418. It has 3 residential units across 3 floors. The owner of record is Lakshmi LLC. HPD has recorded 10 housing violations here, most recently on February 27, 2015.
- HPD violations
- 10
- DOB violations
- 9
- ECB violations
- 25
- HPD complaints
- 2
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 10
- IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Feb 27, 2015
Closed — Violation closed - CImmediately hazardous
Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface using work practices set forth in 28 rcny ?11-06(b)(2) north wall in the 2nd room from east at north located at apt na, 2nd story, 1st apartment from east at south
Nov 2, 2012 · Apt NA
Closed — Violation closed - CImmediately hazardous
Correct the lead-based paint hazard - presumed lead paint that is peeling or on a deteriorated subsurface using work practices set forth in 28 rcny ?11-06(b)(2) west wall in the 3rd room from east at north located at apt na, 2nd story, 1st apartment from east at south
Nov 2, 2012 · Apt NA
Closed — Violation closed - ANon-hazardous
Section 300 m/d law file plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration drop ceiling erected 1 sty apt 1r bathroom. , section '' ''
Nov 14, 1988 · Apt 1R
Closed — Violation closed - ANon-hazardous
Section 300 m/d law file plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration suspended celotex clg erected bathrm 1 sty apt1l.
Nov 14, 1988
Closed — Violation closed - BHazardous
D26-19.05 adm code provide adequate light of not less than 60 watts incandescent or equivalent illumination vestibule & 1 sty pub hall.
Nov 14, 1988
Closed — Violation closed - ANon-hazardous
Provide a lock and key to the entrance door of dwelling unit and, if a cl a multiple dwelling, also chain door guard entrance to 1 sty apt 1l. located at apt 1l
Oct 27, 1988 · Apt 1L
Closed — Violation closed - ANon-hazardous
Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mail box sign missing 1 sty pub hall.
Oct 27, 1988
Closed — Violation closed - ANon-hazardous
Section 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor frame missing.
Oct 27, 1988
Closed — Violation closed - ANon-hazardous
Section 300 m/d law file plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration suspended ceiling installed 1 sty apt 1r kitchen. located at apt 1r
Oct 27, 1988 · Apt 1R
Closed — Violation closed
DOB building violations · 9
- Immediate emergency anythingoptional
Imegncy-immediate emergency anythingoptional
Jan 17, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 1, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 1, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 1, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 1, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 1, 2014
Dob violation - dismissed - Immediate emergency anythingoptional
Imegncy-immediate emergency anythingoptional
Oct 17, 2013
Dob violation - dismissed - Construction other optional
Failure to maintain building due to fire
Oct 12, 2013
Dob violation - active - Construction other optional
Failure to maintain building due to gas explosion
Oct 12, 2013
Dob violation - dismissed
ECB violations · 25
- Class - 1
Unsafe conditions - inadequate housekeeping and missing handrails continues to be an issue throughout the site and is a recurring condition as previously observed on 6/28/2023 (violation #39518417p and #3951841
Mar 17, 2025 · Penalty $5,000
Resolve - Class - 1
Found : great amount of construction debris front and rear side, no documents on site no competent person designed, missing handrails from 2nd to roof level, no disability insurance no fire extinguishers on sit
Mar 17, 2025 · Penalty $12,500
Resolve - Class - 1
At time of inspection requested to worker on site documentation like ssp super ,preshift , orientation and tool box taking log books . all dob permits like fence work, and dot permits but none was providedstop
Mar 17, 2025 · Penalty $6,250
Resolve - Class - 2
New 3 story building at time of inspection noted fence permit q00607907-i1-fn has been expired on 02-25-2025 contrary to(bc105.8.2 and bc106.8.2)
Mar 17, 2025 · Penalty $3,125
Resolve - Class - 1
Observed an active project with workers conducting construction operations. on researching dob now; found the gc's disability insurance (through amguard insurance co. - policy #db08073090.1) expired on 2/25/202
Mar 17, 2025 · Penalty $12,500
Resolve - Class - 2
Time of inspection at 3 story new building close site observed temporary equipment fence at all exposure. upon researched on dob website dobnow/bis determine that fence permit q00607907-i1-fn was expired on 10/
Nov 15, 2023 · Penalty $3,125
Resolve - Class - 2
At the time of my inspection i observed cold form steel installed at 1st-2nd floor upon asking for joist hangers connection details , manufacturing specifications , special inspection log-none were provided-sto
Jun 28, 2023
Resolve - Class - 1
At the time of my inspection i observed windows openings(from floor aprox16inch)-10/20 feet to ground level,stairway openings aprox 10 feet deep -and no guardrail system provided at any window/stairway opening
Jun 28, 2023 · Penalty $12,500
Resolve - Class - 1
At the time of my inspection i observed a big amount of debris , garbage bags , wood ,plywood , equipment -aprox 3 feet high on exp#3 backyard scattered all over the area
Jun 28, 2023 · Penalty $6,250
Resolve - Class - 1
At the time of my inspection i observed stairways going from 1st floor to 2nd floor and no hand rails provided
Jun 28, 2023 · Penalty $6,250
Resolve
Show 15 more ↓
- Class - 2
There is a shear cut at exposure # 1 but plans shows 45 degrees slope.
Apr 6, 2023 · Penalty $3,125
Resolve - Class - 2
At the time of inspection jobsite was closed. as per perimeter inspection i observed, construction fence was not fully enclosed. missing fence panel at exposure # 2 & 3 (adjacent property). additionally, fence
Aug 15, 2022 · Penalty $5,000
Active - Class - 1
107.7.1,28-101.2,3304.2 the respondent failed to meet the minimum requirement of the code and provided foundation support of excavation drawings for job that didn't identify the bottom of adjoining footing at 8
Jan 27, 2022 · Penalty $6,250
Resolve - Class - 1
Failure to provide protection at side of excavation.note:at the time of my inspection of an excavation construction with work in progress with 3 workers.i observed on side there were no guard point in place or
Dec 28, 2021 · Penalty $5,000
Resolve - Class - 1
Bc 3304.7 maintain egress of excavation note:at the time of my inspection of an excavation site,i observed work in progress at approximately10 feet with 3 worker.i also observed of ceil level there were no egre
Dec 28, 2021 · Penalty $2,500
Resolve - Class - 1
Permit holder failedto ensure worker received site safety orientation note:at the time of my inspection of an excavation site with work in progress,i observed three worker on site.upon my request for orientatio
Dec 28, 2021 · Penalty $2,500
Resolve - Class - 1
Failure to maintain/display onsite document required by bc chapter 33.note:at the time of my inpsection of excavation site with work in progress i observed to three worker perform concrete work.upon my request
Dec 28, 2021 · Penalty $625
Resolve - Class - 1
Construction superintendent failed to perform duties per code.note:at the time of my inspection of an excavation site,i observed superintendent haven't perform duties.(1)failure to provide site safety plan,(2)f
Dec 28, 2021 · Penalty $2,500
Resolve - Class - 2
Failure to comply w/the commissioner's order to file a c/c w/the dob for vio #vio1713imegncy7140, vio #vio1213cer01fc. observed at time of inspection, no demolition had been completed as ordered since 10.30.13
Jan 16, 2014 · Penalty $4,000
Resolve - Class - 1
Work w/o a permit. at the time of inspection i observed 2 kitchen sinks, 2 water closets, 2 lavatories and 2 showers installed in the cellarw/o a permit. also noted new waste lines and hot and cold water lines
Oct 12, 2013 · Penalty $8,000
Resolve - Class - 1
Failure to maintain bldg in code compliant manner. at the time of inspection i observed that the gas line servicing one gas range in the cellar is disconnected from the unit and left unplugged. all disconnected
Oct 12, 2013 · Penalty $25,000
Resolve - Class - 1
Work w/o a permit. at the time of physical inspection i observed the following installed in the cellar w/o a permit. 1) one bp boiler. 2) 1a.o. smith hot water heater. 3) 2 gas ranges. also noted new gas lines
Oct 12, 2013 · Penalty $8,000
Resolve - Class - 1
Gas being supplied to bldg w/o inspection and certification by dob. atthe time of inspection i observed 1 bp boiler/1 a.o. smith hwh and 2 gas ranges in operation w/o gas authrization inspections must be done
Oct 12, 2013 · Penalty $5,000
Resolve - Class - 1
Failure to have new or altered plumbing system tested. at the time of physical inspection i observed 1 boiler, 1 hwh and 2 gas ranges installed in the cellar w/o gas test done. gas test must be performed on all
Oct 12, 2013 · Penalty $5,000
Resolve - Class - 1
Work w/o a permit.upon physical insp observed 3 pcs bathroom,toilet,shower,sink,kitchen sink,gas stove:installed w/o a permit on the basement level (left side).partial stop work order for basement(entire)rem:ob
May 3, 2011
Resolve
Complaints
- Heating
Heat related
Oct 29, 2012 · Apt NA
Close - Plumbing
Sewer
Aug 27, 2011 · Apt BSMNT
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Walk-up apartment building (C0)
- Year built
- 2022
- Floors
- 3
- Residential units
- 3
- Building area
- 3,140 ft²
- Lot area
- 3,325 ft²
- Zoning
- R5
- Community board
- 409
- Council district
- 29
- Block / lot
- 9332 / 26
- Assessed value
- $50,040
- Landmark / historic district
- No
HPD registration #418038, last renewed Aug 20, 2013.
Questions about 87-40 124 Street
Who owns 87-40 124 Street?
The owner of record in NYC Department of City Planning PLUTO data is Lakshmi LLC.
Does 87-40 124 Street have violations?
Yes. NYC HPD has recorded 10 housing violations at this property.
Is 87-40 124 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 87-40 124 Street built?
City records list 2022 as the year it was built.
How many apartments are in 87-40 124 Street?
It has 3 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.