40-29 235 Street
Queens, NY 11363BBL 4-08099-0061Map
Owner of record: 40-27/29 235th Street Realty LLC
40-29 235 Street is an office building built in 1935 in Queens, 11363. The owner of record is 40-27/29 235th Street Realty LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 26
- ECB violations
- 62
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 26
- Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 17, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 17, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 17, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 17, 2019
Dob violation - dismissed
Show 16 more ↓
- Construction other optional
Boro commissioner has issued an immediate stop work order for work under job # 421656817-01 pl due to plumbing permit holder withdrawal
Sep 21, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Construction other optional
C-construction other optional
Mar 16, 2019
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Mar 16, 2019
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Mar 16, 2019
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Mar 16, 2019
Vp*-violation unserved ecb- dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2015 inspection report
Feb 24, 2017
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2014 inspection report
Oct 1, 2015
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2013 inspection report
Mar 3, 2015
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 31, 2005
Dob violation - dismissed
ECB violations · 62
- Class - 2
Scf training cert card not readily available for insp atoi of active jobsite i observed 3workers on top of pipe scf i ask for sst cards all were presented i ask for scf cards only1 was provided (victor zhou 3/9
May 19, 2022
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments.at time of inspection of active site observed overhead protection at exp #3 cross bracing in wrong location framing should be
Mar 15, 2022
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments.at time of inspection of active site observed sidewalk shed at exp #1 parapet wall 4 ft from curb plans(drawings) indicate the
Mar 15, 2022
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments.at time of inspection of active site observed pipe scaffold missing stacking pins frame level at all exp #1 #2 #3 missing stac
Mar 15, 2022
Resolve - Class - 2
Failure to maintain/display on site documents required by bc chapter 33.at time of inspection of active jobsite observed no pre-shift being performed for today competent person was doing pre-shift every week sh
Mar 15, 2022
Resolve - Class - 2
Failure to protect adjoining structures(general).noted:at time of my inspection of an alteration type-1,2 storie building,construction in progress,approx 3 workers on site,i observed the adjoining structure at
Dec 8, 2021
Resolve - Class - 2
Work does not conform to approved plans and/or approved amendments.at time of inspection observed construction fence at exp #3 did not conform to design drawings onsite.fence had no diagonal bracing as per plan
Nov 8, 2021
Resolve - Class - 2
Failure to safeguard all persons and property affected by construction operation.at time of inspection observed excavation area onsite inside excavation saw steel reinforcement bars sticking up without rebar ca
Nov 8, 2021 · Penalty $5,000
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temporary construction-no guard rails/inadequate guardrail system.at time of inspection of active construction observed inadequate guard rail system ve
Nov 8, 2021 · Penalty $2,500
Resolve - Class - 1
Failure to protect sides of excavation.at time of inspection observed excavation area at exp #3 more than 6 feet deep and had no protection on sides to prevent fall hazards.remedy:provide protection at excavati
Nov 8, 2021 · Penalty $2,500
Resolve
Show 40 more ↓
- Class - 2
Failure to obtain temporary construction permit prior to installation /use of temporary construction equipment-no permit for supported scaffold.at time of inspection of active construction site observed work on
Nov 8, 2021 · Penalty $625
Resolve - Class - 1
Failure to maintain/display on site documents required by bc chapter 33.at time of inspection of active construction site observed no daily inspection log for sidewalk shed no installation inspection report no
Nov 8, 2021 · Penalty $1,250
Resolve - Class - 1
Bc3314.1 supported scaffold not maintained as per code.at time of inspection observed supported scaffold frame used on different floors of building under construction.observed no base plate and mudsills for sup
Nov 8, 2021 · Penalty $625
Resolve - Class - 2
Failure to comply with executive order 202.6.at time of inspection on a proposed 2-story alteration site observed 4 workers on site performing soil baring & test pits as per rescind given on 2/25/20.observed 3
Apr 8, 2020 · Penalty $5,000
Resolve - Class - 2
Construction fence & sidewalk shed have both expired fence expiration date-11-07-19. sidewalk shed expiration date-6/10/19, renew permit; renew both permits
Jan 22, 2020 · Penalty $1,250
Resolve - Class - 2
Permit expired for temporary construction equipment on site (heavy duty sidewalk shed) at time of inspection of a proposed 2 story exten sion and 1 story addition to existing commercial building.i observed
Aug 16, 2019 · Penalty $3,125
Resolve - Class - 1
3307.7.2:gate at time of inspection observed active job site inadequate gate has been found at jobsite the gat open to the outside to the public accessible to () to pedestrian area i also observed the gate cons
Jul 22, 2019 · Penalty $2,500
Resolve - Class - 1
Handrails at time of inspection observed actiev jobsite the handrails was not provide at stairs case as required the staircase was 1st floor to rquired was not provided handrails and consruction debris onstairs
Jul 22, 2019
Resolve - Class - 2
Competent persons at time of my inspection observed actiev job site the competent person was not avalible or preent at job sit eduring construction and during my inspection upon request for competent person wor
Jul 22, 2019
Resolve - Class - 1
Permit holder failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed pablo medardo hernandez at a building site for which a construction su
Jul 22, 2019 · Penalty $12,500
Resolve - Class - 2
Pedestrian protection at time of my inspection observed actiev jobsite the sidewalk shed was not working (was not pack) connection as required pedestrian does not meet code specifications upon request for worke
Jul 22, 2019 · Penalty $2,400
Resolve - Class - 1
3306.9.8.4;steam and fuel at time of my inspection observed actiev job site the oil tank for boilers ands all pipe at job site was not remove as required 2 story building 1st floor level under construction all
Jul 22, 2019
Resolve - Class - 1
Owner failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed christobal revelo barrera at a building site for which a construction superint
Jul 22, 2019
Resolve - Class - 1
Workers employer failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed eugenio de jesus castillo at a building site for which a constructi
Jul 22, 2019 · Penalty $5,000
Resolve - Class - 1
Owner failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed pablo medardo hernandez at a building site for which a construction superinten
Jul 22, 2019 · Penalty $5,000
Resolve - Class - 1
X307.6.2:sidewalk shed at time of my inspection observed actiev job site th esidewalk shed installed at exp-1 was not covering structured with 5'0 from edge of the building as required sidewalk 5'0 was not exte
Jul 22, 2019
Resolve - Class - 1
Housekeeping at time of inspection observed actiev job site the adequate housekeeping has not been maintain as required the construction materials debris (throught) all around the site and blocking egress erect
Jul 22, 2019 · Penalty $2,500
Resolve - Class - 1
Osha card.at time of my inspection ovserved actiev jobsite to workers was workingat jobsite upon required for osha card none was provider or was nto avalable for site for inspection as required stop all work pr
Jul 22, 2019
Resolve - Class - 1
Work does not conform approved document at time of inspection observed actiev job site the shoring provided for existing brick wall at exp-4 and shoring provided to structured beam was not as per drawings and w
Jul 22, 2019 · Penalty $2,500
Resolve - Class - 1
Owner failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed estoban guevara at a building site for which a construction superintendent, ss
Jul 22, 2019 · Penalty $5,000
Resolve - Class - 1
Owner failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed eugenio de jesus castillo at a building site for which a construction superint
Jul 22, 2019 · Penalty $5,000
Resolve - Class - 1
Workers employer failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed estoban guevara at a building site for which a construction superin
Jul 22, 2019 · Penalty $5,000
Resolve - Class - 2
Superintendnet futies at time of inspection my inspection observed actiev job site the construction superinetdnet was not avalable or present at job site during construction and during my inspection upon reques
Jul 22, 2019 · Penalty $2,500
Resolve - Class - 1
Workers employer failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed pablo medardo hernandez at a building site for which a construction
Jul 22, 2019 · Penalty $5,000
Resolve - Class - 1
Owner failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed juan ramon castillo at a building site for which a construction superintendent
Jul 22, 2019 · Penalty $5,000
Resolve - Class - 1
Workers employer failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed christobal revelo barrera at a building site for which a constructi
Jul 22, 2019
Resolve - Class - 1
Workers employer failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed juan ramon castillo at a building site for which a construction sup
Jul 22, 2019 · Penalty $5,000
Resolve - Class - 1
Permit holder failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed estoban guevara at a building site for which a construction superinten
Jul 22, 2019 · Penalty $12,500
Resolve - Class - 1
Permit holder failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed cristobal revelo barrera at a building site for which a construction s
Jul 22, 2019 · Penalty $12,500
Resolve - Class - 1
Permit holder failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed juan ramon castillo at a building site for which a construction superi
Jul 22, 2019 · Penalty $12,500
Resolve - Class - 1
Permit holder failed to produce for inspection daily log that is required by 3321.2, item 3, produce the daily log for inspection
Jul 22, 2019 · Penalty $6,250
Resolve - Class - 1
Permit holder failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1: observed eugenio de jesus castillo at a building site for which a construction
Jul 22, 2019 · Penalty $12,500
Resolve - Class - 2
Job site fence not maintained or constructed to code. at the time of inspection i observed the fate on the job site fence less than the required 8 feet. viewing panels constructed of wire mess not as per code.
Apr 19, 2019 · Penalty $400
Resolve - Class - 1
Failure to provide osha training. at time of inspection at an active jobsite alt-1 proposed 2 sty extension it was observed 6 workers on jobsite & upon request for osha training card worker alfonso martinez did
Mar 16, 2019
Resolve - Class - 1
Failure to provide osha training. at time of inspection at an active jobsite alt-1 proposed 2 sty extension it was observed 6 workers at jobsite,upon request for osha training card worker pedro galan did not
Mar 16, 2019 · Penalty $5,000
Active - Class - 1
Failure to provide osha training. at time of inspection at an active jobsite alt-1 proposed 2 sty extension it was observed 6 workers on jobsite & upon request for osha training card worker alex gutierrez did
Mar 16, 2019
Resolve - Class - 1
Failure to provide osha training. at time of inspection at an active jobsite alt-1 proposed 2 sty extension it was observed 6 workers on jobsite & upon request for osha training card worker jorge salinas rodrig
Mar 16, 2019 · Penalty $5,000
Resolve - Class - 1
Failure to provide osha training. at time of inspection at an active jobsite alt-1 proposed 2 sty extension it was observed 6 workers on site & upon request for osha training card worker julio hernandez did not
Mar 16, 2019
Resolve - Class - 1
Sec. 3309.10 failure to protect or adeqautely protect adjoining properties during construction or demolition operation-roof protection. at time of inspection at an active job site alt-1 for proposed 2 sty exten
Mar 16, 2019 · Penalty $2,500
Resolve - Class - 2
Failure to produce after hour variance-no after hour variance. at timeof inspection at an active jobsite alt-1 for proposed 2 sty extension,it was observed 6 workers on site on a saturday 3-16-19 at 11am upon
Mar 16, 2019 · Penalty $625
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Office building (O2)
- Year built
- 1935
- Floors
- 3
- Residential units
- —
- Building area
- 7,073 ft²
- Lot area
- 10,128 ft²
- Zoning
- R1-2
- Community board
- 411
- Council district
- 19
- Block / lot
- 8099 / 61
- Assessed value
- $694,800
- Landmark / historic district
- No
Questions about 40-29 235 Street
Who owns 40-29 235 Street?
The owner of record in NYC Department of City Planning PLUTO data is 40-27/29 235th Street Realty LLC.
Does 40-29 235 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 40-29 235 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 40-29 235 Street built?
City records list 1935 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.