43-02 Colden Street
Queens, NY 11355BBL 4-05141-0001Map
Owner of record: 43-02 Colden LLC
43-02 Colden Street is an elevator apartment building built in 2012 in Queens, 11355. It has 7 residential units across 6 floors. The owner of record is 43-02 Colden LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 6
- ECB violations
- 27
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 6
- Construction other optional
Reqst 4 info:bldg is partialy demo'd steel structure to ground level, foundation.previously proposd plans not code compliant & not followed structure hasn't been fully demolished. remedy: provide as-built plans for remaining structure, proof of construction composition,probe&scan plans 4 unknown areas,plans/calcs4new structure by 2/2/24
Jan 24, 2024
Dob violation - active - Construction other optional
Boro commissioner has issued stop work order for # 440235327 due to revocation of approvals and permits
May 12, 2017
Dob violation - active - Construction other optional
Boro commissioner has issued immediate stop work order for # 420255976
Oct 26, 2016
Dob violation - active - Construction other optional
Boro commissioner has issued immediate stop work order for # 440235327 due to revocation of permits & approvals
Oct 26, 2016
Dob violation - active - Construction other optional
Spec immed hazardous vio:work against stop work order on 9/29/15 a partial rescind was allowed on properties swo permitting demo&shoring of structure as per plan amendment for job via #440235327.remedy:eng'r of record to amend plans to show current as built cond&steps req for shoring&partial demo of existing structure.submit to dhoyt by 9/30/16
Sep 15, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 2, 2013
Dob violation - dismissed
ECB violations · 27
- Class - 2
Job site fence not constructed or maintained pursuant to subsection. as noted: at time of inspection 6 story a stalled construction job sitewas closed observed at exposure #2, no hunter green paint plywood, exp
Mar 22, 2024 · Penalty $5,000
Active - Class - 2
Temporary construction equipment or installation on site-expired permit. as noted: at time of inspection construction site of a proposed 2 story building was closed. observed construction plywood fence permit h
Jan 26, 2024
Resolve - Class - 2
Work without permit (expired)temporary construction equipment-construction fence.note:at time of inspection of alteration type 2-partial demolition project observed construction fence in place surrounding proje
Jul 21, 2021
Resolve - Class - 1
Sec. 3301.13.1 site safety plan that meets requirements of article 110of chapter 1 of title 28. at time of inspection at a 4 sty alteration,i observed 3 owrkers on site removing structural steel on the 4th fl w
Jan 25, 2021 · Penalty $2,500
Resolve - Class - 1
Sec. 3309.10 protection of roofs(neighboring property)exp#2. at time of inspection at a 4 sty alteration,i observed 3 workers on site removing steel beams on the 4th fl w/o roof protection on exp#2 adjacent pro
Jan 25, 2021 · Penalty $2,500
Resolve - Class - 1
Sec. 3307.6.2 area to be required(where required)exp#2/3. at time of inspection at a 4 sty alteration,i observed 3 workers on site removing structures steel on the 4th fl w/o overhead protection/shed exp#2/3
Jan 25, 2021 · Penalty $2,500
Resolve - Class - 1
Sec. 3301.1.2 fire code. at time of inspection at a 4 sty alteration,iobserved workers on site removing/demo structure steel on 4th fl torc hing/burning steel w/o license/burning license to remove steel worker
Jan 25, 2021 · Penalty $2,500
Resolve - Class - 2
Failure to comply with the commissioner's order contained in summons/violation#35348858x issued on 8/30/18 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01(d)(2).an acceptible cert
Jun 18, 2019 · Penalty $625
Resolve - Class - 2
Temporary construction equipment on site-expired permit. noted:const. fence under application #420255976 fn has expired as of 04/-7/17.renew permit
Aug 30, 2018 · Penalty $1,250
Resolve - Class - 2
Work w/o a permit,expired permit as noted: at time of inspection con- struction site is closed. construction fence permit #420255976-01-eq- fn has expired 5/4/13.rmdy: renew fence permit and post permit @constr
Oct 1, 2013
Resolve
Show 17 more ↓
- Class - 2
Temp construction equipment on site - expired permit. noted: at time of inspection for nb under construction has 8'high wood construction fence erected under permit #420255976 w/expiration date 5.4.13 w/no
Sep 19, 2013
Resolve - Class - 2
Failure to post dot permit for street/sidewalk closing. at time of inspection, construction fence erected over sidewalk to curb, closing sidewalk w/no valid permit posted on cherry street side.remedy:post valid
Sep 19, 2013
Resolve - Class - 2
Failure to comply w/the commissioner's order to file a c of c w/the dept of buildings for notice of violation #34778993m issued on 10/10/12 pursuant to 28-204.4 & 1rcny 102-01. for failure to collect & contain
Apr 8, 2013 · Penalty $400
Resolve - Class - 2
Failure to comply w/the commissioner's order to file a c of c w/the dept of buildings for notice of violation #34779019n issued on 9/18/12 pursuant to 28-204.4 & 1rcny 102-01. for failure to provide/produce a
Apr 8, 2013 · Penalty $400
Resolve - Class - 2
Failure to safeguard all persons & property affected by const operations. noted: jobsite netting is not properly attached & in danger of becoming airborne in high winds. remedy: maintain & correct noted hazard.
Feb 8, 2013 · Penalty $1,200
Resolve - Class - 2
Job site fence not construction pursuant to subsection. note: fence panels are loose,not & adequately attached on north & south side. nb 3420255976 remedy: maintain & repair fence.
Feb 8, 2013
Resolve - Class - 2
Sec. bc 3301.7. failure to provide pe approved design drawing. as noted: at time of inspection at an active construction site, structural steel to flr 6. failure to provide pe approved design drawings for steel
Oct 19, 2012 · Penalty $800
Active - Class - 2
Sec. 28-104.7. submittal of construction documents as noted: at time of inspection concrete placement at exp 2 knee wall grade level and flr #2. observed at flr #3 a structural steel balcony erect, failure to
Oct 10, 2012 · Penalty $800
Resolve - Class - 2
Failure to collected & contained concrete washout water. as noted: at time of inspection concrete placement at knee wall exp 2 grade level & flr 2, observed at exp 4 (cherry ave) concrete truck #14 washing out
Oct 10, 2012 · Penalty $1,200
Resolve - Class - 1
Sec. 28-407.1 failure to provide a n.y. state welders license. noted: at time of inspection steel erection,bolting & welding in progress,observed worker welding. steel beams unable to produce a valid ny state
Sep 18, 2012 · Penalty $1,600
Resolve - Class - 2
Failure to provide special inspection of concrete placement. as noted:at time of inspection at an active construction observed concrete placement at cellar level approx 915 yds at 4,0000 psi. failure to have a
Sep 6, 2012 · Penalty $1,500
Resolve - Class - 2
Sec. 28-105.5. forms filed w/dob do not have required signatures. as noted: at time of inspection at an active construction site observed concrete placement @ cellar level approx 9.5 yds at 4,000 psi tr1 file
Sep 6, 2012
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. upon inspection work ongoing under permit #420255976, contractor installed soldier piles at exp 2 contrary to approved plan.
Jul 17, 2012
Resolve - Class - 2
Sec. 28-104.7.7. failure to file tr1 form and designate operation subject to controlled inspection on plans prior to the commencement of work under controlled inspection. upon inspection proper engineer stamp
Jul 17, 2012
Resolve - Class - 2
Sec. 3309.6 failure to monitor adjoining structures for movement in all directions during excavation related operations that may adversely affect adjoining structures excavation work on going under permit #
Jul 12, 2012
Resolve - Hazardous
Work w/o a permit. work noted : at cellar level remove garage door andinstalled brick wall and window to create bedroom erected partitions to create (2) other rooms. installed water and waste line for (3) piece
Jun 8, 2004
Resolve - Hazardous
Residence altered for occupancy as a dwelling for more than the legally approved number of families. dept. of buildings records indicate residence to be a legal (2) family dwelling. residence is now altered for
Jun 8, 2004
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D6)
- Year built
- 2012
- Floors
- 6
- Residential units
- 7
- Building area
- 11,188 ft²
- Lot area
- 4,306 ft²
- Zoning
- R6
- Community board
- 407
- Council district
- 20
- Block / lot
- 5141 / 1
- Assessed value
- $467,100
- Landmark / historic district
- No
Questions about 43-02 Colden Street
Who owns 43-02 Colden Street?
The owner of record in NYC Department of City Planning PLUTO data is 43-02 Colden LLC.
Does 43-02 Colden Street have violations?
NYC HPD has no housing violations on record for this property.
Is 43-02 Colden Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 43-02 Colden Street built?
City records list 2012 as the year it was built.
How many apartments are in 43-02 Colden Street?
It has 7 residential units and 8 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.