6-03 Parsons Boulevard
Queens, NY 11357BBL 4-04453-0005Map
Owner of record: Peccia, Jennifer
6-03 Parsons Boulevard is an one-family home built in 1930 in Queens, 11357. It has 1 residential unit across 2 floors. The owner of record is Peccia, Jennifer. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 7
- ECB violations
- 20
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 7
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 16, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 16, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 16, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 16, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 16, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 16, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 16, 2019
Dob violation - dismissed
ECB violations · 20
- Class - 2
Failure to provide approved/accepted construction documents at job site at time of inspection. at time of inspection premises under alteration 1 #421323892, at time of inspection no approved plans were produced
Nov 14, 2019
Resolve - Class - 1
Permit holder failed to ensure each construction or demolition worker successfully completed the required training under bc 3321.1: observed calvin buckridge and plummer sadique mohamed at a building site for w
Nov 14, 2019
Resolve - Class - 1
Owner failed to ensure each construction or demolition worker successfully completed the required training under bc 3321.1: observed calvin buckridge and plummer sadique mohamed at a building site for which a c
Nov 14, 2019
Resolve - Class - 1
Worker employer failed to ensure each construction or demolition worker successfully completed the required training under bc 3321.1: observed calvin buckridge and plummer sadique mohamed at a building site for
Nov 14, 2019
Resolve - Class - 2
Failure to provide viewing panel protection.at the time of my inspect-ion to respond to a complaint, 2 story inactive site observed no protection provided for job site viewing panel protection as per code
Jul 8, 2019 · Penalty $400
Resolve - Class - 1
Sec. 3314.5 platform construction-scaffold not fully planked or tied down. at time of inspection observed an erected pipe scaffold at exp#1 2,3&4 that is not fully planked & planks arent tied down. scaffold is
Jan 29, 2019 · Penalty $2,500
Resolve - Class - 1
No handrails.at time of inspection observed no handrails on the stairsfrom 1st floor level to basement level and at stairs from 2nd floor level down to the 1st floor level observed inadeqaute handrails and they
Jan 29, 2019 · Penalty $2,500
Resolve - Class - 1
Sec. 3301.13.12 competent person. at time of inspection observed 2 workers on site working at basement level. observed hazardous conditions upon my entrance to the site such as obstruction of egress at exp#1
Jan 29, 2019
Resolve - Class - 1
Failure of permit holder to designate &/or hace a construction superintendent & competent person present at site when required. at time of inspection observed 2 workers on site working at basement level observe
Jan 29, 2019 · Penalty $10,000
Resolve - Class - 1
Failure to file evidence of compliance w/workers comp,law &/or diability benefits. at time of inspection observed 2 workers on site at basement level. upon further research on bis it was observed that the worke
Jan 29, 2019 · Penalty $5,000
Resolve
Show 10 more ↓
- Class - 2
Bc3303.9.egress maintenance during construction at time of inspection observed at exposure #1-obstructed means of egress and ingress at first floor level. a pipe scaffold approx.20ft in height was erected in fr
Jan 29, 2019 · Penalty $1,250
Resolve - Class - 1
Bc334.8.no guardrail system for pipe scaffold.at time of inspection observed pipe scaffold erected at exposures #1,#2,#3 and #4 with no guardrail system in place.the pipe scaffold is approx.18ft to 20ft in hei
Jan 29, 2019 · Penalty $2,500
Resolve - Class - 1
Construction superintendent failed to do duties at time of inspection of a 2 sty alt-1 observed 2 workers on site that stated they worked for bg management one worker had his osha card & the other did not obser
Jan 29, 2019
Resolve - Class - 2
Temporary construction equipment on site.expired permit at time of inspection observed a jobsite fence installed at exposure #1 of property.upon further research on bis and dob now it was observed that the fenc
Jan 29, 2019 · Penalty $1,250
Resolve - Class - 1
Unlawfully continued work while on notice of a stop work order at the time of inspection it was observed that the contractor stripped the concrete forms & back filled while on a stop work order. a stop work ord
Mar 30, 2018
Resolve - Class - 2
Bc 3301.7. failure to provide construction super daily logs. at time of inspection observed an active construction site with rebar and concrete work in progress for foundation wall. during inspection constructi
Feb 27, 2017
Resolve - Class - 1
Failure to notify dob within 24-48 of the start of excavation. at time of inspection observed an active construction site with rebar and concrete work in progress. during inspection after search on bis noted t
Feb 27, 2017 · Penalty $1,200
Resolve - Class - 1
Work without permit. at time of inspection observed an active construction site with rebar and concrete work in progress for foundation walls. during inspection after search on bis noted that the contractor did
Feb 27, 2017 · Penalty $1,600
Resolve - Class - 1
Bc 3304.4.4. failure to provide guardrails around open and accessible sides of excavation. at time of inspection observed an active construction site with rebar and concrete work in progress for foundation wal
Feb 27, 2017 · Penalty $1,600
Resolve - Class - 2
28-104.2.2. failure to provide approved plans at job site at time of inspection. at time of inspection observed an active construction site with rebar and concrete work in progress. during inspection requested
Feb 27, 2017
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- One-family home (A3)
- Year built
- 1930
- Floors
- 2
- Residential units
- 1
- Building area
- 3,232 ft²
- Lot area
- 6,790 ft²
- Zoning
- R1-2
- Community board
- 407
- Council district
- 19
- Block / lot
- 4453 / 5
- Assessed value
- $141,720
- Landmark / historic district
- No
Questions about 6-03 Parsons Boulevard
Who owns 6-03 Parsons Boulevard?
The owner of record in NYC Department of City Planning PLUTO data is Peccia, Jennifer.
Does 6-03 Parsons Boulevard have violations?
NYC HPD has no housing violations on record for this property.
Is 6-03 Parsons Boulevard rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 6-03 Parsons Boulevard built?
City records list 1930 as the year it was built.
How many apartments are in 6-03 Parsons Boulevard?
It has 1 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.