31-22 Union Street
Queens, NY 11354BBL 4-04414-7501Map
Owner of record: Union Plaza INC.
31-22 Union Street is a condominium built in 2006 in Queens, 11354. It has 20 residential units across 7 floors. The owner of record is Union Plaza INC.. HPD has recorded 130 housing violations here, most recently on March 18, 2026. 26 of the 50 most recent violations are still open.
- HPD violations
- 130
- DOB violations
- 15
- ECB violations
- 10
- HPD complaints
- 130
What to know
Immediately hazardous issues among recent violations are still open.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 130
- CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective latch and hinges at fire stair exit door (labeled as a) at public hall, 1st story
Mar 18, 2026
Open — Nov sent out - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective latch at compactor closet door( labeled as 7th floor) at public hall, 6th story
Jul 6, 2025
Closed — Violation closed - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective hinges at hopper door in compactor closet (labeled as 7th floor) at public hall, 6th story
Jul 6, 2025
Closed — Violation closed - BHazardous
Replace with new the missing latch at hopper door inside compactor closet (labeled as 8th floor) at public hall, 7th story
Jul 6, 2025
Open — Nov sent out - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective latch at hopper door inside compactor closet (labeled as 8th floor) at public hall, 7th story
Jul 6, 2025
Closed — Violation closed - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective hinges at compactor closet door labeled as (8th floor) at public hall, 7th story
Jul 6, 2025
Closed — Violation closed - BHazardous
Provide dwelling with a janitor or responsible person or janitorial service.
Apr 29, 2024
Closed — Violation dismissed - BHazardous
Refit sliding windows at east wall in the 3rd room from north located at apt 2c, 2nd story, 1st apartment from north at east
Jan 25, 2024 · Apt 2C
Open — Nov sent out - BHazardous
Refit door to balcony in the 1st room from north located at apt 2c, 2nd story, 1st apartment from north at east
Jan 25, 2024 · Apt 2C
Open — Nov sent out - CImmediately hazardous
M/d law abate the nuisance consisting of scalding hotwater consisting of 136 degrees exceeding the maximum allowable temperature of 130 degrees at all hotwater fixtures in the entire apartment located at apt 2c, 2nd story, 1st apartment from north at east
Jan 25, 2024 · Apt 2C
Open — Nov sent out
Show 40 more ↓
- CImmediately hazardous
M/d law abate the nuisance consisting of padlockable slidebolt installed at door in the entrance located at apt 7c, 7th story, 1st apartment from north at east
Dec 6, 2023 · Apt 7C
Open — Nov sent out - BHazardous
Repair the roof so that it will not leak over ceiling in the foyer located at apt 7c, 7th story, 1st apartment from north at east
Dec 6, 2023 · Apt 7C
Open — Nov sent out - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color ceiling in the foyer located at apt 7c, 7th story, 1st apartment from north at east
Dec 6, 2023 · Apt 7C
Open — Nov sent out - BHazardous
Refit casment sliding window sash in the 1st room from east at south located at apt 2c, 2nd story, 1st apartment from north at east
Dec 6, 2023 · Apt 2C
Open — Nov sent out - CImmediately hazardous
Install the missing or repair/replace the defective window guard(s) in accordance with the specifications of the new york city health code section 24 rcny chapter 12. wg to install = 1, wg to replace = 2, wg to repair = 0 in the entire apartment located at apt 2c, 2nd story, 1st apartment from north at east
Dec 6, 2023 · Apt 2C
Open — Nov sent out - BHazardous
Replace with new the missing door handle and assembly at door leading to terrace in the 1st room from east at north located at apt 2c, 2nd story, 1st apartment from north at east
Dec 6, 2023 · Apt 2C
Open — Nov sent out - CImmediately hazardous
Replace with new the missing lock at balcony door in the 1st room from east located at apt 2c, 2nd story, 1st apartment from south at west
Oct 6, 2023 · Apt 2C
Open — Nov sent out - CImmediately hazardous
Properly repair or replace the broken or defective lock at apartment entrance door in the entrance located at apt 2c, 2nd story, 1st apartment from south at west
Oct 6, 2023 · Apt 2C
Closed — Violation closed - BHazardous
Refit apartment entrance door in the entrance located at apt 2c, 2nd story, 1st apartment from south at west
Oct 6, 2023 · Apt 2C
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective wood floor in the 2nd room from east at south located at apt 2c, 2nd story, 1st apartment from south at west
Oct 6, 2023 · Apt 2C
Closed — Violation closed - BHazardous
Properly repair with similar material the broken or defective wooden floor in the 1st room from north at east located at apt 2c, 2nd story, 2nd apartment from north at east
Aug 30, 2023 · Apt 2C
Open — Nov sent out - BHazardous
Refit doors in the 1st room from east at south located at apt 2c, 2nd story, 2nd apartment from north at east
Aug 30, 2023 · Apt 2C
Open — Nov sent out - BHazardous
Provide dwelling with a janitor or responsible person or janitorial service.
Aug 30, 2023
Open — Nov sent out - BHazardous
Remove all encumbrances consisting of household articles at public hall, 3rd story
Aug 11, 2023
Open — Nov sent out - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective the hopper door at compactor closet, 3rd story
Aug 11, 2023
Closed — Violation closed - BHazardous
Repair the flushing apparatus and maintain same so as to flush effectively the water closet .. in the bathroom located at apt 3a, 3rd story, 1st apartment from east at south
Aug 3, 2023 · Apt 3A
Open — Nov sent out - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 3a, 3rd story, 1st apartment from east at south
Aug 3, 2023 · Apt 3A
Open — Notice of issuance sent to tenant - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 3a, 3rd story, 1st apartment from east at south
Aug 1, 2023 · Apt 3A
Closed — Violation dismissed - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective compactor chute in compactor closet at east wall at public hall, 3rd story
Aug 1, 2023
Closed — Violation closed - BHazardous
Repair or replace the smoke detector defective in the entire apartment located at apt 3a, 3rd story, 1st apartment from east at south
Aug 1, 2023 · Apt 3A
Open — Nov sent out - BHazardous
Repair or replace the carbon monoxide detecting device(s). defective in the entire apartment located at apt 3a, 3rd story, 1st apartment from east at south
Aug 1, 2023 · Apt 3A
Open — Nov sent out - BHazardous
Properly repair or replace the broken or defective shut off value at water supply line to water closet in the bathroom located at apt 3a, 3rd story, 1st apartment from east at south
Aug 1, 2023 · Apt 3A
Open — Nov sent out - CImmediately hazardous
Abate the infestation consisting of roaches at compactor closet, 2nd story
Jun 20, 2023
Open — Nov sent out - ANon-hazardous
Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper.
Jun 20, 2023
Open — Nov sent out - ANon-hazardous
Paint with light colored paint to the satisfaction of this department at north wall at public hall, 1st story
Jun 7, 2023
Open — Nov sent out - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective hopper door at compactor closet at public hall, 2nd story
Jun 7, 2023
Closed — Violation closed - CImmediately hazardous
Abate the infestation consisting of roaches at compactor closet, 2nd story
Jul 11, 2022
Open — Not complied with - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective from cellar leading to building front (east yard)
Jul 11, 2022
Closed — Violation dismissed - BHazardous
Remove all encumbrances consisting of household items and bicycle in the north fire stairs b at 7th story
Jul 11, 2022
Closed — Violation dismissed - CImmediately hazardous
Remove the illegal fastening consisting of double cylinder key operated lock installed on building entrance door
Jul 11, 2022
Closed — Violation closed - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective hopper door inside compactor chute closet at 5th, 3rd and 2nd stories in the public hall
Jul 11, 2022
Closed — Violation dismissed - BHazardous
Repair or replace the smoke detector defective located at apt 2c, 2nd story, 1st apartment from north at east
Jul 11, 2022 · Apt 2C
Closed — Violation closed - BHazardous
Repair or replace the carbon monoxide detecting device(s). defective located at apt 2c, 2nd story, 1st apartment from north at east
Jul 11, 2022 · Apt 2C
Closed — Violation closed - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective ... in the entrance located at apt 2c, 2nd story, 1st apartment from north at east
Jul 11, 2022 · Apt 2C
Closed — Violation dismissed - ANon-hazardous
Refit fire door ''b'' at fire stairs, 1st story
Aug 17, 2021
Closed — Violation dismissed - BHazardous
Remove all encumbrances consisting of household items at fire stairs, 7th story
Aug 17, 2021
Closed — Violation dismissed - ANon-hazardous
Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected at public hall, 1st story
Aug 5, 2021
Closed — Violation dismissed - ANon-hazardous
Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd. at public hall, 1st story
Aug 5, 2021
Closed — Violation dismissed - BHazardous
Repair or replace the smoke detector missing in the entire apartment located at apt 8c, 8th story, 1st apartment from north at east
Aug 5, 2021 · Apt 8C
Closed — Violation dismissed - BHazardous
Provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules. in the entire apartment located at apt 8c, 8th story, 1st apartment from north at east
Aug 5, 2021 · Apt 8C
Closed — Violation dismissed
DOB building violations · 15
- Elevator elevatorrequired
E-elevator elevatorrequired
Mar 11, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 28, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 23, 2019
Dob violation - resolved - No report and / or late filing (facade) facade required
Failed to file fisp cycle 8a technical report by 02/21/2017
May 31, 2018
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 20, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 29, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 14, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 14, 2014
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - active - Elevator elevatorrequired
This pvt replaces pvt 479423
Jun 28, 2013
Dob violation - resolved
Show 5 more ↓
- Elevator elevatorrequired
E-elevator elevatorrequired
Nov 13, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 11, 2011
Dob violation - resolved - Construction other optional
C-construction other optional
Sep 9, 2010
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 30, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 25, 2008
Dob violation - resolved
ECB violations · 10
- Class - 2
Failure to submit an acceptable required cycle 8a report of critical examination documenting condition of exteiror wall and appurtenances required by 28-302.4 for control #814306 agg1:prior nov 37011888x under
Apr 1, 2021
Resolve - Class - 2
2x10, 60x10, 99m7, 98m7 2x10-outside comm inoperative/60x10-machinelights inoperative /99m7-current year test missing provide. 98m7- current year testing missing provide.
Apr 5, 2019 · Penalty $310
Resolve - Class - 1
(cease use)70.h.14,02.x.10,40.i.10,60.x.10,57.bb.11,40.o.02,98.m.07,99.m.07,39.x.10,68.m.07=978-h-14) shorten gov ropes (02-x-10)repair phone (41-i-10)repair machine room 1)car (60-x-10) repair lighting in mach
Mar 13, 2019 · Penalty $1,280
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #814306.rem: submit required technical report.
May 18, 2018 · Penalty $6,250
Active - Class - 3
Work w/o permit. noted: at exposure #1 1st fl a new awning has been installed approx 26f long x 3'ft wide x 3'ft height & 10'f height from the sidewalk w/lettering "union st pharmacy inc" w/o permits.
Oct 15, 2010
Resolve - Class - 2
Occupancy contrary to that allowed by the c of o. noted: c of o #401856390f issued on 7-26-06 indicated on 1st fl to occupied as community facility & medical office (ug 4a) now at 1st fl observed a pharmacy
Oct 15, 2010
Resolve - Class - 2
Occupancy contrary to that allowed by cert of occupancy noted c of o #401856390f issued on 7/26/06 indicated on 1st fl to occupied as community facility & medical office (vg 4a) now @ 1st fl has been created ph
Oct 15, 2010
Resolve - Class - 2
Illegal use in residential district. noted in r5d-general residence district has created a pharmacy store @ 1st floor vg 6 contrary to zoning regulations. rem:discontinue illegal use.
Oct 15, 2010 · Penalty $800
Resolve - Class - 3
Work does not conform to approved construction documents and/or approved amendments for procert alt ii job#410047907 dwg 12/31/07 permit expired 9/7/08 noted location of lab room sink is contrary to plan lab ro
Nov 30, 2009 · Penalty $100
Resolve - Non-hazardous
Work without a valid permit work permit 401856390 nb expired 12/24/04 expired 12/24/04 work noted construction of 4 story steel frame story steel frame structure remedy:stop all work obtain a valid permit
Jan 6, 2005 · Penalty $2,500
Resolve
Complaints
- General
Ventilation system
Aug 6, 2026 · Apt WHOLEB
Close - Plumbing
Water supply
Apr 16, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Mar 18, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Mar 17, 2026 · Apt BLDG
Close - Unsanitary condition
Garbage/recycling storage
Jul 3, 2025 · Apt BLDG
Close - Plumbing
Water supply
Jul 1, 2025 · Apt 7C
Close - Plumbing
Water supply
Jul 1, 2025 · Apt BLDG
Close - General
Janitor/super
Apr 10, 2024 · Apt 2C
Close - Elevator
Maintenance
Apr 10, 2024 · Apt 2C
Close - General
Janitor/super
Mar 25, 2024 · Apt 2C
Close
Show 40 more ↓
- General
Janitor/super
Mar 20, 2024 · Apt 2C
Close - Heat/hot water
Apartment only
Jan 24, 2024 · Apt 2C
Close - Door/window
Door
Jan 24, 2024 · Apt 2C
Close - Heat/hot water
Apartment only
Jan 7, 2024 · Apt 3A
Close - General
Mailbox
Jan 7, 2024 · Apt 3A
Close - Heat/hot water
Apartment only
Dec 2, 2023 · Apt 3A
Close - Flooring/stairs
Floor
Nov 24, 2023 · Apt 2C
Close - Plumbing
Bathtub/shower
Nov 24, 2023 · Apt 2C
Close - Door/window
Window frame
Nov 24, 2023 · Apt 2C
Close - Paint/plaster
Wall
Nov 24, 2023 · Apt 2C
Close - Door/window
Door
Nov 24, 2023 · Apt 2C
Close - Door/window
Door
Nov 24, 2023 · Apt 2C
Close - Water leak
Slow leak
Nov 21, 2023 · Apt 8C
Close - Water leak
Heavy flow
Nov 21, 2023 · Apt 8C
Close - Paint/plaster
Wall
Oct 3, 2023 · Apt 2C
Close - Door/window
Door
Oct 3, 2023 · Apt 2C
Close - Door/window
Door
Oct 3, 2023 · Apt 2C
Close - Flooring/stairs
Floor
Oct 3, 2023 · Apt 2C
Close - Water leak
Slow leak
Sep 29, 2023 · Apt 8C
Close - Water leak
Heavy flow
Sep 29, 2023 · Apt 8C
Close - Door/window
Door frame
Aug 28, 2023 · Apt 7C
Close - Door/window
Door frame
Aug 28, 2023 · Apt BLDG
Close - Flooring/stairs
Floor
Aug 28, 2023 · Apt 2C
Close - General
Ventilation system
Aug 28, 2023 · Apt 2C
Close - Paint/plaster
Wall
Aug 28, 2023 · Apt 2C
Close - Door/window
Door
Aug 28, 2023 · Apt 2C
Close - General
Ventilation system
Aug 28, 2023 · Apt 3C
Close - General
Janitor/super
Aug 28, 2023 · Apt 2C
Close - Electric
Outlet/switch
Jul 31, 2023 · Apt 3A
Close - Unsanitary condition
Pests
Jul 31, 2023 · Apt 3A
Close - Plumbing
Toilet
Jul 31, 2023 · Apt 3A
Close - Electric
Outlet/switch
Jul 30, 2023 · Apt 3A
Close - Unsanitary condition
Pests
Jul 30, 2023 · Apt 3A
Close - Plumbing
Toilet
Jul 30, 2023 · Apt 3A
Close - Unsanitary condition
Pests
Jul 19, 2023 · Apt 3A
Close - General
Ventilation system
Jul 19, 2023 · Apt 2C
Close - General
Janitor/super
Jul 19, 2023 · Apt 2C
Close - Unsanitary condition
Pests
Jun 15, 2023 · Apt 2C
Close - General
Janitor/super
Jun 15, 2023 · Apt 2C
Close - Door/window
Door
May 30, 2023 · Apt 2C
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Condominium (RM)
- Year built
- 2006
- Floors
- 7
- Residential units
- 20
- Building area
- 24,930 ft²
- Lot area
- 6,500 ft²
- Zoning
- R5D
- Community board
- 407
- Council district
- 20
- Block / lot
- 4414 / 7501
- Assessed value
- $2,215,809
- Landmark / historic district
- No
HPD registration #427732, last renewed Mar 26, 2026.
Questions about 31-22 Union Street
Who owns 31-22 Union Street?
The owner of record in NYC Department of City Planning PLUTO data is Union Plaza INC..
Does 31-22 Union Street have violations?
Yes. NYC HPD has recorded 130 housing violations at this property.
Is 31-22 Union Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 31-22 Union Street built?
City records list 2006 as the year it was built.
How many apartments are in 31-22 Union Street?
It has 20 residential units and 25 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.