23-25 49 Street
Queens, NY 11103BBL 4-01016-0550Map
Owner of record: St Michaels P E Church
23-25 49 Street is a miscellaneous property built in 1957 in Queens, 11103. The owner of record is St Michaels P E Church. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 7
- ECB violations
- 26
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 7
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed
ECB violations · 26
- Class - 2
The permit holder failed to comply with the commissioner's order and submit a certificate of correction to the department of buildings. bc263 was served for no compliance recorded for a class one violation, 395
Oct 24, 2025 · Penalty $1,280
Resolve - Class - 2
No en drawing approved from dob provided on the job site at the time of inspection., maintain/display required documents; please go to https://www1.nyc.gov/site/buildings/codes/energy-conservation-code.page and
Sep 17, 2025
Resolve - Class - 1
At the time of my inspection, i observed: proposed 3 story building in progress with footprint approximately 9,853 sq. ft. site close and there was no construction activities. upon shouting at perimeter and ban
Aug 23, 2025
Resolve - Class - 2
Failure to maintain. noted: observed at side yard of cemetery (right side of entrance to cemetery) there are two shipping containers stacked to a height of 20 ft. the 7 ft fence is also leaning and in a state o
Nov 21, 2023
Resolve - Class - 3
Work without permit. noted: observed 6 electric switches for lifting and closing gates installed for 15.5' ft gates at 49th street. no permits found in department records., obtain permit
Jul 19, 2021
Resolve - Class - 3
Work without permit. noted: observed approx. 15.5' h x 95' l automated gate/fence installed at 49th street exceeding permitted height., conform fence to height requirement
Jul 19, 2021
Resolve - Class - 1
Bc 3314.4.5.2 workers using supported scaffold to perform their job without proper training.at time of inspection at an active new building construction job site,i observed two workers working on supported scaf
May 26, 2020 · Penalty $2,500
Resolve - Class - 1
Bc 3314.8 top boards.at time of inspection at an active new building construction job site,i observed two workers performing construction activities on supported scaffold at exposure #3.i further observed there
May 26, 2020 · Penalty $625
Resolve - Class - 2
3314.1-failure to maintain scaffold as per code subsection observed scaffold erected at 3rd floor approx 12 feet in height scaffold is not dully planned missing guardrails base plates and access ladder also fou
Jan 11, 2020
Resolve - Class - 1
Failure to safeguard all persons & property affected by construction. at time of inspection i observed workers hanging over the leading edge of the bldg w/no fall arrest system or ppe. there were no guardrails
Mar 13, 2019
Resolve
Show 16 more ↓
- Class - 1
No osha training cards provided. at the time of inspection i observed a worker on the roof wearing a grey sweat shirt & black pants. he could not provide an osha card or any identification. an osha 10 hour trai
Mar 13, 2019 · Penalty $5,000
Resolve - Class - 1
No osha training card provided-employer failed to ensure worker completed required training. at the time of inspection i observed a worker on the roof wearing a black jacket & brown pants who could not provide
Mar 13, 2019 · Penalty $5,000
Resolve - Class - 1
No osha training card-employer failed to ensure eworker completed required training. at time of inspection i observed a worker on the roof wearing jeans,a purple sweatshirt & a black hat. he could not provide
Mar 13, 2019 · Penalty $5,000
Resolve - Class - 2
Failure to provide approved/accepted construction documents at jobsite at time of inspection. at the time of inspection approved plans couldnot be provided. design drawings for platform at roof level could not
Mar 13, 2019
Resolve - Class - 1
Unsafe storage of combustible material. at the time of inspection i observed workers on the roof working w/.propane tanks & torches. there were tanks throughout the job on the 1st & 2nd fl not in use & not prop
Mar 13, 2019 · Penalty $2,500
Resolve - Class - 1
No osha card provided at time of inspection i observed a worker on the roof wearing a black jacket & brown pants. he could not provide an osha training card or id. on a site which requires a superintendent.
Mar 13, 2019 · Penalty $5,000
Resolve - Class - 1
No guardrails. at time of inspection i observed open staircases w/no guardrails. these straircases had no guardrails on stairs & landings at every level of the bldg. remedy: provide guardrails.
Mar 13, 2019 · Penalty $2,500
Resolve - Class - 1
Sec. 3303.2.3.1 no temporary lighting for construction site. at the time of inspection i observed there were no lighting. the job site was completely w/o any temporary lighting. there were workers on site & haz
Mar 13, 2019 · Penalty $625
Resolve - Class - 1
Construction superintendent failed in his duties. at time of inspection i observed 4 workers w/no osha cards working at the leading edge of the roof over 36feet w/no fall arrest system. there were no guardrails
Mar 13, 2019 · Penalty $10,000
Resolve - Class - 1
No osha training. at time of inspection i observed a worker on the roof wearing a grey sweatshirt & black plants. he could not provide an osha card or identification for a job which a superintendent is required
Mar 13, 2019 · Penalty $5,000
Resolve - Class - 1
Failure to safeguard all person & property affected by construction. at the time of inspection observed no construction. at the time of inspection observed no construction fence. the mausoleum being constructed
Mar 13, 2019 · Penalty $2,500
Resolve - Class - 1
No competent person on site during construction. at time of inspectioni observed 4 worker on site w/no competent person on site. the construction superintendent was also not on site at time of inspection. the
Mar 13, 2019 · Penalty $10,000
Resolve - Class - 1
No osha training card provided-employer failed to ensure worker completed required training. at time of inspection i observed a worker on the roof wearing jeans,a purple sweatshirt,& black hat. he could not pro
Mar 13, 2019 · Penalty $5,000
Resolve - Class - 1
No osha card training-employer failed to ensure worker completed required training. at the time of inspection required training. at the timeof inspection i observed a worker on the roof wearing a black jacket &
Mar 13, 2019 · Penalty $5,000
Resolve - Class - 1
No osha training-at the time of inspection i observed a worker on the roof wearing jeans,a purple sweatshirt,& a black hat. he could not provide identification or an osha card which is required for a constructi
Mar 13, 2019 · Penalty $5,000
Resolve - Class - 1
No osha training-at time of inspection i observed a worker on the roofwearing a grey sewatshirt & black pants. he could not provide id or the required osha training card. remedy: provide osha training.
Mar 13, 2019 · Penalty $5,000
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Miscellaneous property (Z8)
- Year built
- 1957
- Floors
- 1
- Residential units
- —
- Building area
- 22,259 ft²
- Lot area
- 170,800 ft²
- Zoning
- R4
- Community board
- 401
- Council district
- 22
- Block / lot
- 1016 / 550
- Assessed value
- $1,838,700
- Landmark / historic district
- No
Questions about 23-25 49 Street
Who owns 23-25 49 Street?
The owner of record in NYC Department of City Planning PLUTO data is St Michaels P E Church.
Does 23-25 49 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 23-25 49 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 23-25 49 Street built?
City records list 1957 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.