Owner of record: Lic Property Holdings, LLC
37-08 34 Street is an elevator apartment building built in 2024 in Queens, 11101. It has 44 residential units across 6 floors. The owner of record is Lic Property Holdings, LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 3
- ECB violations
- 18
- HPD complaints
- 1
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 3
- Construction other optional
Emergency work. potential hazard from soe work. cracks and separation revealed in adjacent exterior exp#4 cmu wall. continued work has left wall destabilized. control no.: 376264. remedy: comply w code, immed cnstrct heel blocks for adjacnt wall stblztn along portion of exp#4 work to done under full time pe & cs supervision. submit daily reports
Nov 14, 2024
Dob violation - active - Construction other optional
Potential hazard due2 soil/foundation issues.observd cracks&separation in exterior wall & slab @ 33-06 37 av.monitoring shows excessive move ment. risk to public safety & adjacent structures. remedy: provide signed/sealed plumbing survey by nys surveyor & coordinate w/ adjoining engineer.submit survey by 11/7/24
Oct 24, 2024
Dob violation - active - Construction other optional
Potential hazrd due2 soil/foundation issues.observed cracks&separation in exterior wall and slab @ 33-06 37th av.monitoring shows excessive movement. risk to public safety and adjacent structures. remedy: start cont. monitorng(optical)of 33-06 37 av & piles. nys pe requird 4 plan(bc3309.16),submit by 10/25.baseline read 10/28/24
Oct 24, 2024
Dob violation - active
ECB violations · 18
- Class - 1
Failure to maintain embeded safety strap installation lob book on site. as noted: at time of inspection at an active construction site of a 6 story concrete cast-in-place building already at the bulkhead level,
Oct 2, 2026 · Penalty $2,500
Active - Class - 1
Failure to maintain adequate housekeeping per section requirement. as noted: at time of inspection of a jobsite of a proposed 6 story building already at the bulkhead level observed from floor 6th to 1st failur
Oct 2, 2026 · Penalty $2,500
Active - Class - 2
At time of inspection observed parapet panel at sidewalk shed at exp 1 & 4 of a 6 story building with the incorrect address creating hazardous conditions to the public and emergency services attempting to locat
Aug 12, 2026 · Penalty $1,250
Resolve - Class - 2
Active 6story nb with inadequate housekeeping in areas on site. combustible debris stored aside stairwells on multiple floors creates fire hazard. noted tripping hazards caused by loose debris and hoses in many
Apr 21, 2026
Resolve - Class - 2
Active 6story nb. noted at areas on site & upper floors inadequate guardrails & vertical netting/cable systems not maintained per 3308.5/3308.7, falling debris can injure those below. netting missing&loose in m
Apr 21, 2026 · Penalty $2,500
Resolve - Class - 2
Active 6story nb. unsafe conditions on site 3301.5. on the 5th flr concrete reshore posts were seen within 10ft of unprotected/unenclosed perimeter not secured to prevent falling from building per 3305.3.6.1.2.
Apr 21, 2026 · Penalty $2,500
Resolve - Class - 2
Active 6story nb. noted supported scaffold at expo3 not maintained per3314. while active work taking place on top level noted no fall protection for workers 3314.8. workers seen erecting sf while work was takin
Apr 21, 2026 · Penalty $2,500
Resolve - Class - 2
Failure to provide means and methods by pe for concrete repairs.as noted:at time of my inspection on an active construction site,6 story newbuilding.observed at cellar level foundation concrete walls cast in pl
Oct 20, 2025 · Penalty $1,250
Resolve - Class - 1
Unsafe storage of combustible material and equipment.as noted:at time of inspection on an active construction site,6 story new building observed at 1st floor oxygen tanks and acetylene tanks storage without val
Oct 20, 2025 · Penalty $2,500
Resolve - Class - 2
Bc 3303.15 observed concrete operation in progress with inadequate concrete wash out box. stop all concrete operation on site obtain concrete wash out box as per code. obtain concrete wash out box as per code.
Apr 21, 2025 · Penalty $2,500
Resolve
Show 8 more ↓
- Class - 2
Bc 3307.2.1 obstruction of sidewalk observed sidewalk closed off and outriggers from concrete pump extended on sidewalk obstruction sidewalk upon requested for dot permit for sidewalk closure none was provided.
Apr 21, 2025 · Penalty $2,500
Resolve - Class - 2
Respondent failed to correct violating condition and file for a certificate of correction pursuant to ac 28-204.4 for violation no. 39533775k issued dated 10/23/2024. at time of inspection, i observed inactive
Dec 24, 2024 · Penalty $1,250
Resolve - Class - 1
Observed structural damages including split btwn slab and extr wall of the exp#3 existing adj building at 33-06 37th ave caused by excavation ops @ 37-04 24 st, excavation ops created a hazardous condition that
Oct 23, 2024 · Penalty $25,000
Resolve - Class - 1
Obsvd 12+ft excavation site with the work having caused damage to the exp#3 adj 1 str warehouse bldg at 33-06 37th ave- large cracks in walls, columns, slab, and 3+ inch separation between the slab and the exca
Oct 23, 2024 · Penalty $10,000
Resolve - Class - 1
Observed a proposed 6 str new residential building under construction- at excavation stage with a 12+ ft deep excavation in place. upon review of department records, i found that no notification had been made t
Oct 23, 2024 · Penalty $2,500
Resolve - Class - 1
Obsvd structural damages @ 33-06 37th ave & split on the slab of the existing bldg due to excavation ops @ 37-04 34 street, no notification on the department records or action taken by the gc, owner or pe regar
Oct 23, 2024 · Penalty $5,000
Resolve - Class - 1
12+ ft excavation w/ multiple areas of soe contrary to dob-aprvd soe plans: vert c-channel brace w/ corner bracing instld along exp#3 adj bldg wall, not on plan; c-channel instld horztly along exp#3 lacks detai
Oct 23, 2024 · Penalty $2,500
Resolve - Class - 2
Failure to maintain bldg walls or appurtenances:note @ several locations 34 street elevator(exp1)hairline cracking @ stucco observed also peeling @ finish also stucco covering steel lintel is cracked & in jeopa
Jul 25, 2014 · Penalty $500
Resolve
Complaints
- Unsanitary condition
Pests
Apr 5, 2021 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D7)
- Year built
- 2024
- Floors
- 6
- Residential units
- 44
- Building area
- 43,697 ft²
- Lot area
- 9,900 ft²
- Zoning
- M1-2/R6A
- Community board
- 401
- Council district
- 26
- Block / lot
- 375 / 20
- Assessed value
- $1,490,400
- Landmark / historic district
- No
Questions about 37-08 34 Street
Who owns 37-08 34 Street?
The owner of record in NYC Department of City Planning PLUTO data is Lic Property Holdings, LLC.
Does 37-08 34 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 37-08 34 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 37-08 34 Street built?
City records list 2024 as the year it was built.
How many apartments are in 37-08 34 Street?
It has 44 residential units and 45 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.