30-12 41 Avenue
Queens, NY 11101BBL 4-00239-0026Map
Owner of record: Largavista 41st Holdings, LLC
30-12 41 Avenue is an office building built in 1924 in Queens, 11101. The owner of record is Largavista 41st Holdings, LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 47
- ECB violations
- 8
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 47
- Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2023
Dob violation - dismissed - Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Dec 1, 2021
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 2, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 14, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 14, 2019
Dob violation - resolved
Show 37 more ↓
- Construction other optional
Boro commissioner has issued stop work order # 421533521 due to applic ant withdrawal
Sep 17, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 2, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 16, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 16, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 14, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 14, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 10, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 10, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 10, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 15, 2012
Dob violation - resolved - Construction other optional
C-construction other optional
Apr 4, 2012
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 4, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 21, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 21, 2011
Dob violation - resolved - Elevator elevatorrequired
Cease use
Aug 12, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 12, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 26, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 26, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 7, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 7, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 7, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 7, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 3, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 3, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 6, 2004
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 6, 2004
Dob violation - resolved - Elevator elevatorrequired
4p2563
Apr 10, 2003
Dob violation - resolved - Elevator elevatorrequired
4f228
Apr 10, 2003
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 4, 2002
Dob violation - resolved - Elevator elevatorrequired
(15)adjust all hoist doors self closers to close doors(15)provide all missing dust covers (55)properly install pit light switch at pit ladder,secure all e.m.t for save properly (53)car top and bottom light repair and provide guard also provide guard top car light (17)glass bsmt & 2nd fl (30)remove sprinkler pipe & head in overhead of shaftway
Oct 10, 1989
Dob violation - resolved - Elevator elevatorrequired
(74)repair car top down inspection run relay or replace same (35) provide missing hoist cable guard rear of machine (55)provide pit light guard,move pit light switch to proper location near pit ladder & secure all emt to same properly (74)provide car top and bottom light guard and repair bottom light
Oct 10, 1989
Dob violation - resolved - Elevator elevatorrequired
(03)replace 2nd fl. glass.(45)provide missing pit stop switch (15)secure from top of car.(47)prov. door lck & handle to outside of door.#9,18,,33,38,35,44 & 51 file bn & secure a permit for installatin of all new equipment as per n.y.c. admin. code rs18.refur cab & 1 fl buck & doors.(44)cov. up holes in bucks. (52)prov. phone in cab
May 8, 1989
Dob violation - resolved - Elevator elevatorrequired
(46)patch all holes shaft way walls as needed throughout shaftway (47)repair motor room door to close properly.(51)provide two way out side communication to car, provide missing phone to phone box.(52) secure top exit cover from top of car
May 8, 1989
Dob violation - resolved - Elevator elevatorrequired
(51)file a bn & obtain a permit from this department for new hoist motor & motor controller car door operator, refurbished cab & hoistway doors & bucks, car & hall station with indicators.(52)prop balanced loan between car & c.w.t
Mar 2, 1989
Dob violation - resolved - Elevator elevatorrequired
(35)*b)remove by pass key switch installed in car
Sep 27, 1988
Dob violation - resolved - Elevator elevatorrequired
(33)4th floor.(51)repair car controller to answer all car & hall calls
Sep 27, 1988
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 3, 1988
Dob violation - resolved
ECB violations · 8
- Class - 1
40m7,42n10,57bb11,67x10,97x17-40m7)no machine room print. 42n10)jumper on controller. 57bb11)machine room fire extinguisher expired. 67x10)outside communication not working. 97x17)upon inspection entire device
Feb 7, 2018
Resolve - Class - 3
Work does not conform to approved construction documents.job #420492933.dwg 11/29/2011.note: 1)4th floor.removed part of public hall walls and installed exit door with walls.remedy:conform to approved document
Mar 21, 2017 · Penalty $230
Resolve - Non-hazardous
22d6,32q3,74m7,35p17. 32-covers on electric boxes. 74-capacity sign in elevator.
Nov 2, 1998
Resolve - Non-hazardous
75u5,36j11,40b7. 40-provide up overspeed tripping switch & certify toproper calibration as per ansi a:17.1 sections 206.4a & 206.4b(3).
Nov 2, 1998
Resolve - Non-hazardous
75u
Dec 23, 1997
Resolve - Non-hazardous
40b75u22d 40-provide up over speed tripping switch and certify to proper calibration as per ansi a: 11 sections 206 4 a and 206 4b (3)
Dec 19, 1997
Resolve - Non-hazardous
Failure to file a report of compliance with local law 16/84-certifying to the installation of required fire protection systems.remedy:file report.
Nov 20, 1992
Resolve - Non-hazardous
Failure to provide adequate(no paper and accurate)elevator lamding signs on each floor and both banks.failure to provide (3")floor number signs.failure to provide (3")stair identification signs.remedy:provide
Nov 20, 1992
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Office building (O2)
- Year built
- 1924
- Floors
- 4
- Residential units
- —
- Building area
- 46,808 ft²
- Lot area
- 12,169 ft²
- Zoning
- M1-6/R10
- Community board
- 401
- Council district
- 26
- Block / lot
- 239 / 26
- Assessed value
- $3,990,600
- Landmark / historic district
- No
Questions about 30-12 41 Avenue
Who owns 30-12 41 Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Largavista 41st Holdings, LLC.
Does 30-12 41 Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 30-12 41 Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 30-12 41 Avenue built?
City records list 1924 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.