35-02 Northern Boulevard
Queens, NY 11101BBL 4-00214-0251Map
Owner of record: 3502 Partners LLC
35-02 Northern Boulevard is a garage / gas station built in 1930 in Queens, 11101. The owner of record is 3502 Partners LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 13
- ECB violations
- 13
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 13
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 8, 2025
Dob violation - dismissed - Construction other optional
Structure rendered non-compliant. at the time of inspection observed building bearing brick wall at rear exposure #3 in disrepair, cracked, bulging and separating from structural columns. noted structural deflection throughout the entire width of the compromised wall. also concrete floor dropping separating from wall.
May 6, 2020
Dob violation - active - Construction other optional
Ftm:bldg dmg due to const @lirr.obs aprx 8'deep exp3 wall had concrete slab on grde undermind/crack/slope.exp3 bear wal bowed outwrd and part detch at sog&intersecting masn walls;exp3 vert crack@exp2/3 cornr.exp3 crack&dislodged at some joist.ownr retn nyspe to eval entire bldg&prep repr dwgs.bldg to be repr'd undr prmt strt by 7/6/20 & cmpl by 9/18/20
May 6, 2020
Dob violation - active - Construction other optional
Emg wrk/partial vacate ordr:multi commerc business part vacat'd @rear of bldg under c#4810527 due to unsafe condns@the exp3 bulg/bear wall & undrmind conc slab on grade that was dmge by adj const.immd instl phys barrier 5'tall min@a dist 25'frm exp3 wall alng full width of bldg.wrk direct&supv pe.file prmt 2 days.subm reprt/photos compl barrier5/8/20
May 6, 2020
Dob violation - active - Construction other optional
Emgy wrk ordr:bldg dmg due to [email protected] on grade undrmind aprx 8'deep alng exp3 wall &crack/slope.exp3 bear wall bowed outwards&part detch from sog.exp3 crack@2/3 crnr.exp3 crack@joist &unstabl.ownr retn nyspe&contr to immd temp shore flr joist @exp3 bear wall.wrk undr supv direct pe.file job 2 day.prov m&m.pe prov daly repts.wrk strt 5/11/20
May 6, 2020
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 3, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 15, 2019
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Vcat1-elevator annual inspection / test elevatorrequired
Oct 8, 2010
Dob violation - active
Show 3 more ↓
- Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 10, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 29, 1995
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 7, 1994
Dob violation - dismissed
ECB violations · 13
- Class - 1
Failure to submit the required parking structure initial observation report for an existing parking structure documenting the conditions of psid#q0002292 by the august 1, 2024 deadline. to date, the department
Oct 1, 2024 · Penalty $1,250
Resolve - Class - 2
Work without permit.note:adjacent tenant allowed entry to second floor when work was being done.i observed at office space with work in progress.i observed new bathroom fixtures and a kitchen along with a new e
Feb 26, 2019 · Penalty $1,280
Resolve - Class - 2
Failure to safeguard all persons + properly affected by construction operatiosn .noted:i observed two men on a scaffold and one holding a ladder on top of the scaffold attaching a platform to the buidling
Feb 26, 2019 · Penalty $5,030
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments for alt ii job #410101269 of which permit expired 4.1.09non conforming work noted against plan dated 4.17.08: 1) found no ac
Jul 16, 2010 · Penalty $500
Active - Class - 2
Work does not conform to approved construction documents &/or approvedamendments insp dwg 07/01/03 pc altii 401690434 exp 01/07/04 note at time of insp found proposed handicap lift make prolift voyager model #3
Jun 9, 2010 · Penalty $500
Active - Hazardous
Failure to maintain bldg - hazardous. defects noted: interior stairs are in poor condition. vinyl/rubber stair treads were removed & not replaced causing an unsafe condition when ascending or descending. also
Dec 14, 2007 · Penalty $2,500
Resolve - Non-hazardous
Exit sign defective/fails to meet bldg code standards. defect noted: exit sign at exit stairs not lit. also noted lighting in same floor hallway is inadequate. remedy: repair/replace sign.
Dec 14, 2007 · Penalty $500
Resolve - Non-hazardous
Exit lighting defective/fails to meet bldg code standards. defects noted: lighting over stairways is defective & inadequate. lack of light over landing which could lead to trips or falls. remedy: repair/replace
Dec 14, 2007 · Penalty $2,500
Resolve - Hazardous
Failure to provide required means of egress for every fl observed: second means of egress block pulled dorm gate/door lock main entrance, remedy: provide second means of egress.
Oct 18, 2007 · Penalty $2,500
Resolve - Non-hazardous
Fail to meet bldg code stds exit lights have no electric power or backup powers.observed:all electric to 2fl turnoff & exit lights did not go on w/back up powers.remedy:repair/replace lighting.
Oct 18, 2007 · Penalty $2,500
Resolve
Show 3 more ↓
- Non-hazardous
Exit sign fails to meet bldg code stds.observed:all electric to 2fl turnoff & exit signs did not light up w/back up power.remedy:replace/repair all signs.
Oct 18, 2007 · Penalty $500
Resolve - Hazardous
Fail to maintain bldg.observed:electric power to 2fl public space(hallway/bathrooms)no provided.causing exit lights & garage not to operate.remedy:maintain bldg/provide electric.
Oct 18, 2007 · Penalty $2,500
Resolve - Hazardous
Failure to maintain. noted: water from above roof, comes in to work area causing dangerous condition for public, fond standing water on floor in work area unsafe to work public. remedy: repair or replace roof.
Oct 28, 2005 · Penalty $800
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Garage / gas station (G9)
- Year built
- 1930
- Floors
- 2
- Residential units
- —
- Building area
- 41,500 ft²
- Lot area
- 29,200 ft²
- Zoning
- M1-5
- Community board
- 401
- Council district
- 26
- Block / lot
- 214 / 251
- Assessed value
- $2,000,700
- Landmark / historic district
- No
Questions about 35-02 Northern Boulevard
Who owns 35-02 Northern Boulevard?
The owner of record in NYC Department of City Planning PLUTO data is 3502 Partners LLC.
Does 35-02 Northern Boulevard have violations?
NYC HPD has no housing violations on record for this property.
Is 35-02 Northern Boulevard rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 35-02 Northern Boulevard built?
City records list 1930 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.