2312 Avenue U
Brooklyn, NY 11229BBL 3-07356-0005Map
Owner of record: 2312 Holdings, LLC
2312 Avenue U is a vacant lot in Brooklyn, 11229. The owner of record is 2312 Holdings, LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 0
- ECB violations
- 17
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 0
No DOB violations on record
ECB violations · 17
- Class - 2
Upon inspection i observed a fence installed at all exposures not maintained or constructed according to code. 8ft height not met at fence entry expos 1. protruding objects and graffiti on fence at expos 1. dam
Apr 1, 2025 · Penalty $1,000
Active - Class - 2
Upon inspection i observed a fence installed at exposure 1 without a complaint project info panel provided contrary to code 3301.9.1 fence project information panel. where a site is enclosed with a fence in acc
Apr 1, 2025 · Penalty $1,250
Active - Class - 2
At time of inspection, upon review bis / dob now, i observed the job site fence permit was expired on 10-25-2024.
Oct 28, 2024
Resolve - Class - 2
At time of inspection, i observed tree at exposure #1 was not protected as per section bc 3309.11. / protect tree
Oct 28, 2024 · Penalty $2,500
Resolve - Class - 2
At time of inspection, i observed sidewalk closure due to construction activities and dot permit not provided upon request for the closure of sidewalk as per bc 3307.2.1.
Oct 28, 2024 · Penalty $2,500
Resolve - Class - 2
At time of inspection, i observed construction activities taking place on sidewalk and no flag person in place to protect or direct pedestrians from such hazardous condition as per section bc 33307.4.4.
Oct 28, 2024 · Penalty $2,500
Resolve - Class - 2
Observation: undermined @ exposure #4 @rear without pe & sia reports. upon my request for pe/sia report none was provided. pswo for undermining @ exposure #4 persaunt to chapter 33 3301.5.provide pe approved pl
Sep 30, 2024 · Penalty $1,250
Resolve - Class - 2
Observation: excavator placed on excavation soil without pe drawing. excavator seated on top of excavated soil. upon request for engineer assessment report to verify if excavated soil can withstand load of exca
Sep 30, 2024 · Penalty $2,500
Resolve - Class - 2
Observation: stayform installed @ exposure 4 without pe approved plans. upon review of approved documents work does not show the use of stayform on plan foundation wall. pswo @ exposure #4 stop all foundation
Sep 30, 2024
Resolve - Class - 2
Observed raker and waler installed to support the excavations operations and raker is bolted to the waler with steel plate and 4 bolts, upon review the approved soe drawings, did not observe any detail for rake
Aug 14, 2024
Resolve
Show 7 more ↓
- Class - 1
Bc3309.9 weatherproof integrity of adjoining buildings.observed foundation wall adjoining property exp#4 exposed, open to elements due to excavation operations, no waterproofing has been provided to restore wat
Aug 14, 2024
Resolve - Class - 2
At time of inspection. workers using excavator machine and performing earthwork. i called out to multiple workers for access to site. no access was provided. access is necessary to conform if site conditions ar
Aug 7, 2024 · Penalty $2,500
Resolve - Class - 1
Bc 3321.1 at the time of my inspection of a 3 story new building at foundation/excavation phase, i observed active job site, upon request for competent person 62hrs site safety training card for compliance he o
Jun 28, 2024 · Penalty $5,000
Resolve - Class - 1
Bc 28-1054.12.8 at the time of my inspection of a 3 story new building at foundation/excavation phase, i observed active job site, upon review of the site safety plan it has no signature of approval. failure t
Jun 28, 2024
Resolve - Class - 1
At the time of my inspection of a 3 story new building at foundation/excavation phase, i observed 4 workers on job site. upon request for site safety orientation and refresher none was presented or at job site.
Jun 28, 2024
Resolve - Class - 1
At time of inspection, no earthwork notification was found via dob now crm for excavation work being done on site.
Jun 12, 2024 · Penalty $2,500
Resolve - Class - 2
At time of inspection; no pre-construction survey, monitoring plan or monitoring reports were provided for optical and vibration monitor devises observed on adjacent properties at exposure #2 and #4 at an exca
Jun 12, 2024 · Penalty $1,250
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Vacant lot (V1)
- Year built
- —
- Floors
- —
- Residential units
- —
- Building area
- —
- Lot area
- 4,000 ft²
- Zoning
- R4
- Community board
- 315
- Council district
- 48
- Block / lot
- 7356 / 5
- Assessed value
- $139,950
- Landmark / historic district
- No
Questions about 2312 Avenue U
Who owns 2312 Avenue U?
The owner of record in NYC Department of City Planning PLUTO data is 2312 Holdings, LLC.
Does 2312 Avenue U have violations?
NYC HPD has no housing violations on record for this property.
Is 2312 Avenue U rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.