roofy

423 Avenue U

Brooklyn, NY 11223BBL 3-07106-0045Map

Owner of record: Turbobrooklyn LLC

423 Avenue U is a store building built in 1931 in Brooklyn, 11223. The owner of record is Turbobrooklyn LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
5
ECB violations
30
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 5

  • Construction other optional

    Wwp

    May 3, 2022

    Vpw*-violation unserved ecb-work without permit-dismissed
  • Construction other optional

    C-construction other optional

    May 3, 2022

    Dob violation - dismissed
  • Construction other optional

    Failure to maintain at time of inspection observed ongoing excavation work and underpining has caused fence of adjoining property 2151 east 3rd street to be pulled away along with vertical cracks on facade

    May 27, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 21, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 5, 2014

    Dob violation - dismissed

ECB violations · 30

  • Class - 1

    At time of inspection 2 story alteration with 4 workers working interior taping/plastering. i observed on 2nd floor loft area was missing guardrails that could lead to appox 10/12 foot fall to ground level and

    Jun 28, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    At time of inspection 2 story alteration with 4 workers working interior taping/plastering. i observed at stairways from ground level leading to cellar and up to 2nd floor was missing handrails. provide handra

    Jun 28, 2023 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection 2 story alteration with 4 workers working interior taping/plastering. i observed 1 worker working off an unsafe pipe scaffolding and not maintained on ground floor level. scaffolding was m

    Jun 28, 2023 · Penalty $1,250

    Resolve
  • Class - 1

    Work w/o permit.note:at time of inspection of inactive site proposed 2 story buidling observed structural work;cmu wall.research of bis no permit for structural work on file.remedy:obtain permit for structural

    May 3, 2022 · Penalty $1,250

    Resolve
  • Class - 2

    Housekeeping note:atoi of inactive site,under const,i observed inadequate housekeeping thruout site,including house materials&garbage.poor housekeeping can cause tripping hazards provide&maintain proper houseke

    May 3, 2022

    Resolve
  • Class - 1

    3301.6.1 no design drawing for temp platform for elevator cover.note:atoi@inactive site,propose 2styb,i observed temp platform on metal decking 2fl level.upon request for design drawing none was provided provid

    May 3, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Missing overhead protection note:atoi,inactive site,propose 2styb,i observe no overhead protection@exp1,2,4 provide overhead protection for public&adj properties affected

    May 3, 2022

    Resolve
  • Class - 1

    Failure to safeguard atoi,observed freestanding wall aprx18'h&aprx20'lw/o bracing putting persons&property@risk of being struck by or crush by collapsing wall or materials.free standing wall should have bracing

    May 3, 2022 · Penalty $10,000

    Resolve
  • Class - 2

    Failure to maintain supported scaffold.at the time of inspection of active a vertical & horizontal alt.new building w/elements to remain.i observed a supported scaffold which was active with worker having no de

    Apr 29, 2022

    Resolve
  • Class - 1

    Failure to provide pedestrian protection for sidewalks and walkways(nosidewalk shed,fence)at the time of inspection of a alt-horiz-vertical enlargement the jobsite was active with a worker on the scaffold insta

    Apr 29, 2022 · Penalty $10,000

    Resolve
Show 20 more ↓
  • Class - 2

    Superintendent competent person not designated,not present,at the time of inspection of a commercial renovation,vertical & horizontal enlargement i observed a active jobsite worker on the scaffold no netting fo

    Apr 29, 2022

    Resolve
  • Class - 1

    Failure to maintain/display on site documents required by bc chapter 33.at time of inspection on an active 2 story nb job site when asking for the following required on site documents none could be provided:(1

    Jan 28, 2022 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction-no guardrails.at time of inspection observed a shaft on 1st fl to cellar w/no guardrails installed.observed at exp.#3 leading

    Jan 28, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Construction superintendent failed to perform duties per code.at time of inspection on an active 2 story nb job site i observed 2 workers onsite installing plywood on the q deck on 1st fl-when asking for the co

    Jan 28, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Bc331444-failure to institute/maintain safety equipment measures or temporary construction while working on supported scaffolding.provide-means/methods for safe scaffold use.at the time of my inspection of the

    Jun 4, 2021

    Resolve
  • Class - 1

    Work does not conform to approved construction documents and/or approved amendments. at time of inspection premises under permit # b00503573-i1-fo-ea observed additional shoring work at expo #2 not indicated on

    May 27, 2021

    Resolve
  • Class - 1

    Failure to maintain record of pre-shift safety meeting for each worker. at time of inspection competent person deigo oswaldo rullova leon states " i don't have a pre-shift log or did we fill one out for 05/27/2

    May 27, 2021

    Resolve
  • Class - 1

    Failure to protect adjoining structures during excavation operations. at time of inspection observed ongoing excavations have damaged adjoining property 2151 east 3rd street where excavations at expo #2 rear un

    May 27, 2021

    Resolve
  • Class - 1

    Failure to provide protection at sides of excavations. at time of inspection observed ongoing excavation work where excavation is at approximately 20' deep at exposure #1 no fall protection implemented. also no

    May 27, 2021

    Resolve
  • Class - 1

    Unlawfully continued work while on notice of a stop work order:at timeof inspection,the 12ft x 12ft x 25ft horizontal extension listed in ecb violation #35097534x & that was located at rear has been observed

    Mar 17, 2021 · Penalty $5,000

    Resolve
  • Class - 1

    Unlawfuk act, failure to comply w/an order of the commissioner. records indicate no application filed to correct,certify & remove violationscontained in summons#35312930r & 3527447p. remedy: comply w/comm's ord

    May 24, 2018 · Penalty $3,125

    Resolve
  • Class - 1

    Unlawful act,failure to comply w/an order of the commissioner. records indicate no application filed to certify,correct & remove violations contained in summons#35274478p. remedy: comply w/comm's order.

    Mar 14, 2018 · Penalty $6,250

    Resolve
  • Class - 1

    Electrical work without permit.electrical wiring of entire store feeders panel branch circuits ceiling outlets,receptacle outlets,fixtures,switches,motors,centers tru-out bld.rem:comply with ec code/obtain perm

    Dec 5, 2017 · Penalty $1,600

    Resolve
  • Class - 2

    Failure to file c of c for nov #35097534x issued on 8/13/14. remedy: comply w/nov.

    Jun 26, 2015 · Penalty $800

    Resolve
  • Class - 1

    Failure to comply w/the commissioner's order contained in notice of violation #35097534y issued on 8/13/14. for work w/o a permit extension in rear of store. remedy: comply w/the comm's order.

    Apr 25, 2015

    Resolve
  • Class - 1

    Failure to comply w/the commissioner's order contained in notice of violation #35097534x issued on 8/13/14. extension in rear w/o permit. remedy: comply w/the comm's order.

    Dec 18, 2014 · Penalty $800

    Resolve
  • Class - 1

    Failure to comply w/commissioner's order contained in nov #35097534x issued on 8/13/14 extension in rear w/o permit. rmdy: comply with commissioner's order.

    Oct 22, 2014 · Penalty $800

    Resolve
  • Class - 1

    Work w/o a permit.work noted:extension being erected @ rear.wood framed structure is approx 12'high x 12'wide x 25'long w/entry door @ rear all new sheeting,roof,wood studs & joist.work is approx 40%completed.r

    Aug 13, 2014 · Penalty $800

    Resolve
  • Class - 2

    Occupancy contrary to that allowed by the c of o,bldg dept records &/or all applicable laws or regulations c of o #212254 indicates bldg to be occupied by factory.illegal occup noted:bldg now occupied by womans

    Aug 13, 2014 · Penalty $1,200

    Resolve
  • Non-hazardous

    Work without a permit. work noted: installed new partitions & new woodsuspending frame at ceiling. remedy: stop all work, obtain a permit including wood frame of suspending ceiling.

    Nov 16, 2004 · Penalty $500

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Store building (K4)
Year built
1931
Floors
1
Residential units
—
Building area
3,190 ft²
Lot area
2,000 ft²
Zoning
R6A
Community board
315
Council district
44
Block / lot
7106 / 45
Assessed value
$289,800
Landmark / historic district
No

Questions about 423 Avenue U

Who owns 423 Avenue U?

The owner of record in NYC Department of City Planning PLUTO data is Turbobrooklyn LLC.

Does 423 Avenue U have violations?

NYC HPD has no housing violations on record for this property.

Is 423 Avenue U rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 423 Avenue U built?

City records list 1931 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.