1889 Mcdonald Avenue
Brooklyn, NY 11223BBL 3-06658-0001Map
Owner of record: Mdy Quentin LLC
1889 Mcdonald Avenue is a school building built in 2024 in Brooklyn, 11223. The owner of record is Mdy Quentin LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 0
- ECB violations
- 15
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 0
No DOB violations on record
ECB violations · 15
- Class - 1
At the time of my inspection, i observed jersey barriers with chain link fence on top covered with debris netting, upon review of the dot permit it allowed to only occupy 8 feet of roadway and the barriers was
Jun 12, 2026 · Penalty $5,000
Active - Class - 1
At the time of my inspection of a 6 story new building, i observed 1 worker operating a forklift, upon request for his certificate to operate according to the manufacture specification none was presented or at
Jun 12, 2026 · Penalty $2,500
Active - Class - 1
At the time of my inspection of a 6 story new building, i observed sidewalk shed in place at exposure #1 and 2, upon review of the site safety plan it reveal that sidewalk shed at exposure #1 should be install
Jun 12, 2026 · Penalty $2,500
Active - Class - 1
At time of inspection of a 6-story active job site, standpipe system and alarm system were in readiness. upon request, no electrical permit for the standpipe alarm system was provided. department records show n
May 28, 2026 · Penalty $1,250
Resolve - Class - 1
At time of inspection of a 6-story active job site, fire hydrants were observed in use. upon request, no dep permit was provided. unauthorized use of fire hydrants creates a hazardous condition. stop all use im
May 28, 2026 · Penalty $2,500
Resolve - Class - 1
Bc 3303.12.2.1 at time of inspection of a 6-story active job site, building topped off at 99 feet with no elevator or hoist in readiness. condition creates hazard to public/property and impedes emergency access
May 28, 2026 · Penalty $5,000
Resolve - Class - 2
Bc3303.3 watchperson 6 story new building, building approximately 19792 square feet. site closed and there were no construction activity. upon shouting at perimeter and banging on fence and door to alert watchp
May 20, 2026 · Penalty $2,500
Resolve - Class - 2
Observed jersey barriers at exp#1 not as per manufactures specification. jersey barriers not continuously interlocked fill with water/sand which poses a potential hazard by allowing unintended movement of the
May 20, 2026 · Penalty $1,250
Resolve - Class - 2
Observation: @ exposure#1 scaffold on needle beams upon my request for needle beams drawing none was provided/displayed. pswo for no manufacure specs for needle beams. stop all scaffold work.provided manufactur
May 4, 2026 · Penalty $6,250
Active - Class - 2
Observation:. @ exposure#1&2 support scaffold has modified cuts throughout. upon my research of scaffold drawing, drawing does not reflect cuts. pswo for scaffolds contrary to plan for modified cuts. stop all s
May 4, 2026
Resolve
Show 5 more ↓
- Class - 1
Failure to institute safety equip measures or temporary construction-"no guardrail". as noted: at time of inspection at an active jobsite for a proposed 6 story building already at the 3 floor level. observed a
Mar 3, 2026 · Penalty $5,000
Resolve - Class - 1
At the time of my inspection observed active site erecting structural steel beams upon request observed red steel fabricator machine in use. site failed to provide manufacturer specifications(3301.6) for diesel
Feb 18, 2026 · Penalty $2,500
Resolve - Class - 2
At time of inspection, no watchperson present on site as required; contrary to bc 3303.3, once the foundation is poured, sites exceeding 5,000 sq ft must maintain a competent watchperson during all non-working
Oct 11, 2025 · Penalty $2,500
Active - Class - 2
Upon inspection i observed a fence installed at exposures 1&4 not constructed or maintained according to code. missing/obstructed viewing panel at expos 1& 4. protruding objects (screws, nails, damaged wood) at
Apr 14, 2025 · Penalty $1,000
Resolve - Class - 2
Upon inspection i observed fence project info panels installed at exposures 1 and 4 contrary to code 3301.9.1.1 project information panel content. a copy of the primary project permit shall be posted or printed
Apr 14, 2025 · Penalty $1,250
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- School building (W2)
- Year built
- 2024
- Floors
- 6
- Residential units
- —
- Building area
- 111,940 ft²
- Lot area
- 13,284 ft²
- Zoning
- R7A
- Community board
- 315
- Council district
- 44
- Block / lot
- 6658 / 1
- Assessed value
- $149,400
- Landmark / historic district
- No
Questions about 1889 Mcdonald Avenue
Who owns 1889 Mcdonald Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Mdy Quentin LLC.
Does 1889 Mcdonald Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 1889 Mcdonald Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 1889 Mcdonald Avenue built?
City records list 2024 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.