roofy

87 Winthrop Street

Brooklyn, NY 11225BBL 3-05045-0068Map

Owner of record: 87 Winthrop, LLC

87 Winthrop Street is an elevator apartment building built in 2025 in Brooklyn, 11225. It has 8 residential units across 5 floors. The owner of record is 87 Winthrop, LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
2
ECB violations
27
HPD complaints
1

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 2

  • Construction other optional

    Ftc-w/comissioner's order vio#071225ceu30901pw(#3a22475) ordered 87 winthrop llc to have eor to review the non-conformance of concrete testing procedure & to submit s/s acceptance statement.as of 6/15/26, 87 winthrop llc has not complied w/comissioner's order.remedy:comply w/comissioner's order & code

    Jun 16, 2026

    Dob violation - dismissed
  • Construction other optional

    Failure to perform standard-curing specimens: during lab inspection @ hrf on 7/1/2025, dob observed dry cylinders stored improperly, not meeting final curing requirements. remedy: comply with codes and astm submit eor-approved alternate results by 09/12/2025

    Jul 21, 2025

    Dob violation - dismissed

ECB violations · 27

  • Class - 2

    At time of inspection observed construction fence installed at exp# 1. upon reviewing in department systems record indicated permit b01161645-s1-fn expires 05/30/2026.

    Jun 14, 2026 · Penalty $1,250

    Resolve
  • Class - 1

    Bc3314.1 observed sup.. scaffold installed at exp#1 3 4 not maintained as per code. missing guardrail system. platforms not fully planks, planks loose not tied down bicycles' stairtowers missing locking pins. l

    Apr 23, 2026 · Penalty $5,000

    Resolve
  • Class - 2

    Bc 3303.9 at time of inspection active site observed accumulation of material stored in pathway obstructing egress to exit building exp# 3. stop all obstruction of egress

    Apr 23, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection observed construction fence door swings outward to the public pathway.

    Apr 23, 2026 · Penalty $1,000

    Resolve
  • Class - 1

    At the time of my inspection of a 4 story new building top off, i observed large amount of construction debris and garbage inside of building approximately 5 to 6 feet and at exposure #3 rear yard. failure to m

    Mar 9, 2026 · Penalty $1,250

    Resolve
  • Class - 2

    Gc-625778 bc3307.2.1 at time of inspection observed generator occupying roadway at exposure#1. upon reviewing dot systems, record indicated no dot permit for generator also no active permit posted and none prov

    Mar 2, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Gc-625778 bc3307.2.1 at time of inspection observed jersey barriers occupying roadway at exposure#1. upon reviewing dot systems, record indicated no dot permit for barriers also no active permit posted and none

    Mar 2, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Gc-625778 observed jersey barriers at exposure#1 not as per manufactures specification. jersey barriers not continuously interlocked fill with water/sand which poses a potential hazard by allowing unintended

    Mar 2, 2026 · Penalty $1,250

    Resolve
  • Class - 1

    During inspection of an active 4-story nb , 5 workers were observed on site. i requested they contact the cs or qsp. they called an individual who stated the work was completed and that no cs or qsp was require

    Feb 26, 2026 · Penalty $10,000

    Resolve
  • Class - 2

    Bc 3314.4.8 _observed pipe scaffold installed at exposure 1. upon inspection, the scaffold was found to be poorly maintained -loose and damaged netting, not compliant with code requirements. this condition crea

    Feb 26, 2026 · Penalty $2,500

    Resolve
Show 17 more ↓
  • Class - 2

    During my inspection the active 4-story nb job site, i requested to provide the following documents: ssp,sws daily log, sws installation letter, sws 6-month inspection letter, pre shift meeting , toolbox talk

    Feb 26, 2026 · Penalty $1,250

    Resolve
  • Class - 2

    During my inspection at the active job site of a 4-story new building ( cs job), i observed unsafe extension cables and exposed wires. this condition poses a significant risk of electrical shock, potentially l

    Feb 26, 2026 · Penalty $800

    Resolve
  • Class - 2

    3309.10_during my inspection of the active job site for a 4-story new building, i observed that the adjacent roof protection at exp #4 was not installed according to code, as it was not fully planked. this lack

    Jan 6, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Bc 3307.2.1 _ failure to comply with dot regulations_at time of inspection on a active jobsite- 4 story nb, i observed that at exp#1 the roadway being occupied by barricades/yodocks.observed no active dot perm

    Jan 6, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    During the inspection, i observed that the sidewalk shed (sws) at exposure #1 was not built or maintained according to code. the steel pipes/columns were out of plumb, and horizontal bracings were missing. th

    Jan 6, 2026 · Penalty $2,400

    Resolve
  • Class - 2

    Bc 3303.7.2_at time of inspection on an active 4 story nb jobsite i observed fire extinguishers on site not maintained to code. inspection tags blank or missing monthly inspection on numerous fire extinguishers

    Jan 6, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    During my inspection of an active 4-story nb, i requested the qsp to provide the records of talkbox talk. however, records from the last two weeks were not provided or available.comply with code

    Jan 6, 2026 · Penalty $1,250

    Resolve
  • Class - 2

    At the time of inspection at the active job site of a 4 story nb ,i observed that housekeeping was not maintained.the site was full of construction debris, building materials, and wood.this creates a dangerous

    Jan 6, 2026

    Resolve
  • Class - 2

    At 6pm observed 4 story building with sidewalk shed that was not illuminated as stipulated in bc3307.6.4.8 creates hazardous conditions for pedestrians of slips and trips due to inadequate lighting in dark cond

    Oct 30, 2025 · Penalty $2,400

    Resolve
  • Class - 2

    Observed jersey barriers at exp#1 not as per manufactures specification. jersey barriers not interlocked fill with water/sand which poses apotential hazard by allowing unintended movement of the barriers incre

    Oct 30, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    Bc 3307.2.1 at time of inspection observed jersy barrier occupying roadway at exp#1 dot permit posted at site expired upon review in dot record indicated no active permit. obtain dot permit for jersey barriers

    Oct 30, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    Bc 3307.2.1 at time of inspection observed generator stored at exp#1 occupying roadway upon review in dot records indicated no permit for generator. obtain dot for generator

    Oct 30, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    B3307.4.7 at time of inspection observed inadequate work and storage zone exp#1 missing 4ft barriers with mesh on top alongside the pedestrian pathway to protect the pedestrian from the work and storage zone.

    Oct 30, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    At time of inspection observed: excavation work contrary to approved drawings.soe-002.00 with the following objections: lagging work on existing pipe soldier piles expo# 2-4 missing welded steel angle to suppor

    May 20, 2025

    Resolve
  • Class - 2

    At time of inspection observed: active job site at excavation stage, contractor failure to safeguard adjoining property expo# 4 undermining and holes at concrete driveway of adjoining property at 91 winthrop st

    May 20, 2025 · Penalty $5,000

    Resolve
  • Class - 1

    At the time of my inspection i observed the barriers at street level provided was not to manufacturer's specifications creating a unsafe condition for personnel and vehicular traffic, barriers were not connecte

    Apr 16, 2025

    Resolve
  • Hazardous

    Occupancy contrary to that allowed by the certificate of occupancy or building department records. 2 family private dwelling. cellar changedfrom storage and ordinary use to b-rooms. partitions erected and sink

    Mar 29, 1999 · Penalty $800

    Resolve

Complaints

  • Plumbing

    Basin/sink

    Dec 7, 2018 · Apt 2

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D1)
Year built
2025
Floors
5
Residential units
8
Building area
9,925 ft²
Lot area
3,781 ft²
Zoning
R6
Community board
309
Council district
40
Block / lot
5045 / 68
Assessed value
$262,800
Landmark / historic district
No

Questions about 87 Winthrop Street

Who owns 87 Winthrop Street?

The owner of record in NYC Department of City Planning PLUTO data is 87 Winthrop, LLC.

Does 87 Winthrop Street have violations?

NYC HPD has no housing violations on record for this property.

Is 87 Winthrop Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 87 Winthrop Street built?

City records list 2025 as the year it was built.

How many apartments are in 87 Winthrop Street?

It has 8 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.