roofy

114 Arlington Avenue

Brooklyn, NY 11207BBL 3-03934-0022Map

Owner of record: 114 Arlington LLC

114 Arlington Avenue is a walk-up apartment building built in 2024 in Brooklyn, 11207. It has 4 residential units across 2 floors. The owner of record is 114 Arlington LLC. HPD has recorded 6 housing violations here, most recently on November 29, 2011. 6 of the 6 most recent violations are still open.

HPD violations
6
DOB violations
2
ECB violations
22
HPD complaints
11

What to know

Concern
2 open Class C

Immediately hazardous issues among recent violations are still open.

Good
Last violation Nov 29, 2011

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 6

  • C

    Repair the roof so that it will not leak over the ceiling , in the 1st room from north at west located at apt 2fl, 2nd story

    Nov 29, 2011 · Apt 2FL

    Open — Nov sent out
  • B

    Abate the nuisance consisting of mice located at apt 2fl, 2nd story

    Nov 29, 2011 · Apt 2FL

    Open — Nov sent out
  • B

    Properly repair with similar material the broken or defective wood floor , in the kitchen located at apt 2fl, 2nd story

    Nov 29, 2011 · Apt 2FL

    Open — Nov sent out
  • B

    Abate the nuisance consisting of roaches located at apt 2fl, 2nd story

    Nov 29, 2011 · Apt 2FL

    Open — Nov sent out
  • B

    Provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules. located at apt 2fl, 2nd story

    Nov 29, 2011 · Apt 2FL

    Open — Nov sent out
  • C

    Repair the broken or defective plastered surfaces and paint in uniform color ceiling , in the 1st room from north at west located at apt 2fl, 2nd story

    Nov 29, 2011 · Apt 2FL

    Open — Nov sent out

DOB building violations · 2

  • Construction other optional

    Work without a permit. work noted. at rear of premises 1 story additio n 34'x18'x10' constructed. note. extension is wooden construction with vinyl siding and has 2 steel entry doors on west side full electrical services noted. remedy. obtain permit or restore pre- mises to prior legal conditions

    Aug 30, 1999

    Vw*-violation - work w/o permit dismissed
  • Construction other optional

    Work without a permit. work noted: a 10 x 12 structure erected/constr- ucter with 4"x4" and 2"x2" treated lumber. roof is made with 2 x 4's with corrugated plastic material used as roofing remedy: obtain permit or restore premises to prior legal condition

    Aug 21, 1999

    Vw*-violation - work w/o permit dismissed

ECB violations · 22

  • Class - 1

    At the time of inspection of a 4-story new building, a pipe scaffold was observed at exp# 1-4 exceeding the height 41-ft building. department records show no scaffold permit on file. this condition creates a ha

    Jun 29, 2026

    Resolve
  • Class - 1

    Observation: no handrails for stairs @ basement & 2ndfloor, stairs w/o infills. guardrails inadequate throughout site. housekeeping inadequate(debri, wood & stone pieces) means &method of fall protection &cmu n

    Oct 17, 2025 · Penalty $10,000

    Resolve
  • Class - 1

    Observation: gc failed to follow precautions for working around powerlines located @ rear yard close proximate to scaffold. pswo for failed to precaution work around powerline. pursaunt to bc 3314.4.4.12 stop

    Oct 16, 2025

    Resolve
  • Class - 2

    Observation: active jobsite, operations on scaffolds, storage of cmu blocks & debris, equipment & materials on unpoured q-deck. no plans to verify loads on unpoured q-deck. pswo for unpoured q-deck. pursaunt to

    Oct 16, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    Observation: cold form steel throught site upon my review of drawings cold form missing light gauge metal c-joist and w/o bridging & bracing. pswo for structural operations. stop all structural operations under

    Oct 16, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    Observation: cold form steel upon my request for special inspection report none was provided. pswo for failure to provide special inspection report pursaunt to chapter bc 1704.1 stop all work under permit #321

    Oct 16, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to safeguard the public and property affected by construction operations. observation: no handrails for stairs @basement and 2nd floor, stairs w/o in fills. guardrails inadequate throughout site. housek

    Oct 16, 2025 · Penalty $10,000

    Resolve
  • Class - 2

    3314.01. observed supported scaffold at all exposure not erected and or maintained as per code requirements. scaffold not platform fully planked with lose planks (not tiedown), no debris netting stop all use o

    Sep 20, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection, i observed 1 tree at exposure #1 was not protected as per code section bc 3309.11. ? protect tree.

    Jul 2, 2025

    Resolve
  • Class - 2

    At the of inspection on a non active job site, upon my research through dob now system i observed that fence permit # b00037679-i1-fn was expired since 11/10/2024 and no new permit was in system or posted on f

    Apr 22, 2025

    Resolve
Show 12 more ↓
  • Class - 1

    Failure to provide required notification prior to the commencement of demolition. at time of inspection observed 2 sty bldg has been demolished. search of dob record show no notication recorded prior to commenc

    May 21, 2019 · Penalty $2,500

    Resolve
  • Class - 2

    Jobsite fence not constructed or maintained pursuant to subsection.(noviewing panels). at time of inspection on demo-monitoring observed jobsite fence missing viewing panels on exp#1. remedy: provide viewing

    May 21, 2019

    Resolve
  • Class - 1

    Failure to provide required notification prior to the commencement of demolition. at time of inspection observed garage has been demolished. search of dob records show no notification recorded prior to commence

    May 21, 2019 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to post or property post permit for work at premises(fence permit). at time of inspection on demo-monitoring observed that no fence permit is posted on jobsite fence. remedy: post/propoerty post permit

    May 21, 2019

    Resolve
  • Class - 2

    Project information panel not provided or not in compliance w/section.at time of demo-monitoring inspection observed that information panel was not eligible. remedy: provide & maintain adequate project panel.

    May 21, 2019

    Resolve
  • Class - 2

    Sec. 28-105.1 work w/o permit. noted: at front of the premises wooden structure erected apprx 10ft x 10ft with glass walls & root. at rear of the premises at 1st fl level extension erected appr 30 ft long w/2

    Jul 20, 2010 · Penalty $6,000

    Resolve
  • Hazardous

    Xork without a permit. work noted:at rear of premises 1story addition 35'x18'x10' constructed. note: extension is wooden construction with vinyl siding. & 2 steel entry doors on westside. full electrical servic

    Aug 30, 1999 · Penalty $2,500

    Resolve
  • Hazardous

    Occupancy contrary to that allowed by bldg dept records illegla occupancy noted garage converted to car repair shop notre cars neing repoared auto bldy work and painting at time of inspection remedy discontinue

    Aug 30, 1999 · Penalty $2,500

    Resolve
  • Non-hazardous

    Illegal use in a residential district. the illegal use: auto body re- pair & storage of five unregister vehicles and discard parts. remedy: discontinue the auto repair, remove the unregister vehicles and parts.

    Aug 26, 1999 · Penalty $2,500

    Resolve
  • Non-hazardous

    Work without a permit. work noted: a 10 x 12 structure erected/const- ructed in front yard of premises. structure constructed with 4"x 4" & 2"x 4" treated lumber. roof is made with 2x4's with corrogated plastic

    Aug 21, 1999 · Penalty $400

    Resolve
  • Non-hazardous

    Illegal storage/parking: in side and rear of yard observed 1 metallic grey 1988 4 door nissan motor vehicle; 1 pontiac bonneville motor vehicle one red 2 door ford motor vehicle and 2 other unrecognized mot

    Aug 21, 1999 · Penalty $240

    Resolve
  • Non-hazardous

    Failure to maintain: in side yard auto parts, construction debris and a dryer being stored on premises. remedy: clean up debris and maintain.

    Aug 21, 1999 · Penalty $180

    Resolve

Complaints

  • Plumbing

    Water-leaks

    Nov 28, 2011 · Apt 2FL

    Close
  • General

    Windows

    Nov 28, 2011 · Apt 2FL

    Close
  • Nonconst

    Vermin

    Nov 28, 2011 · Apt 2FL

    Close
  • Nonconst

    Vermin

    Nov 28, 2011 · Apt 2FL

    Close
  • General

    Floor

    Nov 28, 2011 · Apt 2FL

    Close
  • Heating

    Heat related

    Nov 10, 2011 · Apt 2ND

    Close
  • Heating

    Heat related

    Nov 10, 2011 · Apt 2ND

    Close
  • Plumbing

    Water-leaks

    Nov 10, 2011 · Apt 2ND

    Close
  • Paint/plaster

    Ceiling

    Nov 10, 2011 · Apt 2ND

    Close
  • Paint/plaster

    Ceiling

    Nov 10, 2011 · Apt 2ND

    Close
Show 1 more ↓
  • General

    Windows

    Nov 10, 2011 · Apt 2ND

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C3)
Year built
2024
Floors
2
Residential units
4
Building area
5,610 ft²
Lot area
5,000 ft²
Zoning
R4
Community board
305
Council district
37
Block / lot
3934 / 22
Assessed value
$199,800
Landmark / historic district
No

Questions about 114 Arlington Avenue

Who owns 114 Arlington Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 114 Arlington LLC.

Does 114 Arlington Avenue have violations?

Yes. NYC HPD has recorded 6 housing violations at this property.

Is 114 Arlington Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 114 Arlington Avenue built?

City records list 2024 as the year it was built.

How many apartments are in 114 Arlington Avenue?

It has 4 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.