1743 Linden Boulevard
Brooklyn, NY 11207BBL 3-03865-0053Map
Owner of record: 1743 Linden LLC
1743 Linden Boulevard is a store building built in 1930 in Brooklyn, 11207. It has 2 residential units across 2 floors. The owner of record is 1743 Linden LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 8
- ECB violations
- 18
- HPD complaints
- 3
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 8
- Construction other optional
Atoi, requested dob plans for ongoing construction under permit #: b01247838-i1-gc. no plans provided and plans not onsite. full swo issued op-71-25-06440.
May 13, 2026
Dob violation - active - Construction other optional
Ftm bldg in code compliant manner. bldg has defected conditios at exp3, cracke at 1fl cornder of 1 and 4. cracke at 1fl and flaking of paint. exp 1-damaged light fixture
Oct 19, 2022
Dob violation - active - Construction other optional
Ftm bldg in code compliant manner. bldg has defected conditions at exp3 and exp4. crack, spalling and also damaged light fixture at exp1 remedy: repair and/or replace
Oct 19, 2022
Dob violation - active - Construction other optional
Emergency work order-observed damaged facade/loose masonry at 1fl corner of exp1 and exp4. remedy: immed remove/replace/repair imminent hazardous conditions as per bldg code
Oct 19, 2022
Dob violation - active - Construction other optional
Failure to maintain building in code compliant manner building has damaged masonry on the facade.conditions include openmortar joints, cracked bricks, damaged window lintes,step cracking maintain exterior building facade. comply with code
Apr 1, 2022
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 21, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Aug 10, 2016
Dob violation - dismissed - Construction other optional
@ the time of inspection observed exposure #1 & #4 facade parapet is leaning & out of plumb, approx 12" brick veneer is also bowed/presenting a serious risk to public saftety
Mar 25, 2016
Dob violation - active
ECB violations · 18
- Class - 1
Work does not conform to approved construction documents and/or approv ed amendments. observed panel fence leaning/bulging at exposure 4 and is not properly secured and is missing viewing panels., conform work
Jun 8, 2026 · Penalty $6,250
Resolve - Class - 2
Failure to comply with the commissioner's order to file a certficate of correction with the department of buildings for violation #39188483y, file a certificate of correction
Jun 8, 2026 · Penalty $1,250
Resolve - Class - 2
Failure to comply with the commissioner's order to file a certificate of correction with the dept. of buildings for violation #39188484x., file a certificate of correction
Jun 8, 2026 · Penalty $1,250
Resolve - Class - 2
Failure to comply with the commissioner's order to file a certificate of correction with the dept. of buildings for violation #39188481k., file a certificate of correction
Jun 8, 2026 · Penalty $1,250
Active - Class - 1
Unapproved/unsafe/unsuitable electrical equipment, apparatus, materials, devices, appliances or wiring in use , electric panel in cellar open with exposed live wiring , also electrical outlet connected to elect
Jun 2, 2026 · Penalty $1,600
Resolve - Class - 1
Atoi, observed 2 stories building under renovation. walked site with worker & found building has been vertically & horizontally enlarged without a permit. application filed for enlagement and conversion from 2
May 13, 2026 · Penalty $2,500
Active - Class - 1
Atoi, observed 2 stories building under renovation permit b01247838. work non-conforming. as-built constructed work does not conform to proposed work. as-built description, plan should state 2 units under renov
May 13, 2026 · Penalty $2,500
Resolve - Class - 1
Atoi, observed excessive construction materials & debris laying in path of egress creating a safety hazard to workers & first responders in emergency. gc failed to maintain adequate housekeeping. approx. 50 met
May 13, 2026 · Penalty $2,500
Resolve - Class - 1
Atoi, observed construction fence in disrepair. fence non-compliant- missing viewing vision panels, plywood bulging & not properly secured. bc 3307.7 condition of fences states "with posts in an upright positio
May 13, 2026 · Penalty $1,000
Resolve - Class - 2
Atoi, observed worker on site who provided access, requested approved plans. he stated no plans onsite. he contacted gc project manger and stated plans are not onsite. he has them but he can't provide at this
May 13, 2026 · Penalty $1,250
Active
Show 8 more ↓
- Class - 2
I didn't observed any electrical permit posted on site at the time of inspection., post/properly post permit; post all electrical permits
Nov 8, 2025
Resolve - Class - 2
Pedestrian protection does not meet code specifications. note: at timeof my inspection of a 2 sty bldg at 2 sty stage,no work in progress. iobserved at 5:40am that there were no lights under the sidewalk shed
May 19, 2021
Resolve - Class - 2
Pedestrian protection does not meet code specifications.at time of inspection of a 2 story occupied building i observed sidewalk shed installed at exp#1 & 4 not maintained wood deck and parapet deteriorating/ro
Oct 2, 2019
Resolve - Class - 2
Exit door not self-closing. noted: exit door at rear of the day care is not self closing due to missing door closer. rmdy: repair/ replace door.
Jan 24, 2018 · Penalty $530
Resolve - Class - 2
Failure to provide power for emergency exit lighting noted: emergency exit lighting w/battery pack at linden blvd side observed inoperative due to defetive battery pack or light bulbs. rmdy: provide adequate
Jan 24, 2018 · Penalty $1,250
Resolve - Class - 2
Failure to maintain bldg walls or appurtenances. noted: parpet at exp#1 & 4 out of plumb w/loose & missing mortar. job#340366696 to fix parapet was approved at 5/24/16 but no permit issued. remedy: repair &/or
Oct 1, 2016 · Penalty $500
Active - Class - 1
Failure to maintain bldg in code-compliant manner.noted:@exp#1 & exp#4facade.parapet is warped & out of plub w/loose & missing mortar @2nd story premises.rem:comply w/code.
Jun 24, 2016 · Penalty $1,250
Active - Class - 1
Failure to maintain building in code-compliant manner. note: at the time of inspection observed at exp#1 and #@4 facade, parapet is warped and out of plub with loose and missing mortar, at 2nd story premises.
Mar 25, 2016 · Penalty $500
Resolve
Complaints
- Heating
Heat related
Nov 17, 2003 · Apt 2
Close - Electric
Electric-supply
Nov 17, 2003 · Apt 2
Close - Heating
Heat related
Feb 27, 2003 · Apt 2
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Store building (K4)
- Year built
- 1930
- Floors
- 2
- Residential units
- 2
- Building area
- 2,280 ft²
- Lot area
- 1,800 ft²
- Zoning
- R6
- Community board
- 305
- Council district
- 42
- Block / lot
- 3865 / 53
- Assessed value
- $140,850
- Landmark / historic district
- No
Questions about 1743 Linden Boulevard
Who owns 1743 Linden Boulevard?
The owner of record in NYC Department of City Planning PLUTO data is 1743 Linden LLC.
Does 1743 Linden Boulevard have violations?
NYC HPD has no housing violations on record for this property.
Is 1743 Linden Boulevard rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 1743 Linden Boulevard built?
City records list 1930 as the year it was built.
How many apartments are in 1743 Linden Boulevard?
It has 2 residential units and 3 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.