roofy

28 Vermont Street

Brooklyn, NY 11207BBL 3-03486-0030Map

Owner of record: Sosa, Luis Antonio

28 Vermont Street is a walk-up apartment building built in 1899 in Brooklyn, 11207. It has 3 residential units across 3 floors. The owner of record is Sosa, Luis Antonio. HPD has recorded 150 housing violations here, most recently on June 11, 2025.

HPD violations
150
DOB violations
0
ECB violations
1
HPD complaints
110

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Jun 11, 2025

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 150

  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Jun 11, 2025

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 26, 2024

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 27, 2023

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 2, 2022

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Apr 13, 2021

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 13, 2021

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 31, 2019

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 22, 2018

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 30, 2017

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 16, 2016

    Closed — Violation dismissed
Show 40 more ↓
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 14, 2015

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Feb 25, 2015

    Closed — Violation dismissed
  • C

    Provide permanently seal all accessible openings to building

    Mar 21, 2008

    Closed — Violation dismissed
  • C

    Provide temporary seal all accessible openings to building

    Mar 21, 2008

    Closed — Violation dismissed
  • I

    Apts have been vacated by this department and cannot be reoccupied until so ordered after proof of compliance for apts entire bldg.

    Feb 15, 2008

    Closed — Violation closed
  • I

    Apts have been vacated by this department and cannot be reoccupied until so ordered after proof of compliance for apts .. in the entire apartment located at apt 3, 3rd story

    Feb 8, 2008 · Apt 3

    Closed — Violation closed
  • C

    Provide seal up all accessable openings throughout the building

    Dec 22, 2007

    Closed — Violation dismissed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color ceiling in the entire apartment located at apt 3, 3rd story

    May 27, 2007 · Apt 3

    Closed — Violation closed
  • C

    Provide adequate supply of cold water for the fixtures at kitchen and bath room in the entire apartment located at apt 3, 3rd story

    May 27, 2007 · Apt 3

    Closed — Violation closed
  • B

    Provide adequate supply of hot water for the fixtures at kitchen and bath room in the entire apartment located at apt 3, 3rd story

    May 27, 2007 · Apt 3

    Closed — Violation closed
  • C

    Repair the roof so that it will not leak over ceiling in the entire apartment located at apt 3, 3rd story

    May 27, 2007 · Apt 3

    Closed — Violation closed
  • B

    Provide adequate light of not less than 60 watts incandescent or equivalent illumination no lights 2 nd. and 3 rd story at public hall

    May 27, 2007

    Closed — Violation closed
  • A

    Refit window in the 3rd room from east located at apt 3, 3rd story

    Feb 13, 2007 · Apt 3

    Closed — Violation closed
  • B

    Provide adequate light of not less than 60 watts incandescent or equivalent illumination ... at public hall, 2nd story

    Feb 13, 2007

    Closed — Violation closed
  • C

    Provide ready access to buildings heating system .... at boiler room

    Feb 13, 2007

    Closed — Violation closed
  • B

    Provide adequate supply of hot water for the fixtures kitchen and bath room in the 1st entire apartment from east located at apartment, 3rd story

    Feb 13, 2007

    Closed — Violation closed
  • A

    Refit all windows upper and lower sashes in the entire apartment located at apt 3, 3rd story

    Feb 11, 2007 · Apt 3

    Closed — Violation closed
  • C

    Cleanse and disinfect to the satisfaction of this department after removing the stagnated water . at cellar

    Jan 2, 2007

    Closed — Violation closed
  • B

    Provide adequate light of not less than 60 watts incandescent or equivalent illumination .. at public hall, 2nd story

    Dec 26, 2006

    Closed — Violation closed
  • B

    Provide adequate light of not less than 60 watts incandescent or equivalent illumination at public hall, 2nd story

    Nov 12, 2006

    Closed — Violation closed
  • A

    Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building. at public hall, 1st story

    Oct 18, 2006

    Closed — Violation closed
  • A

    Refit entrance and vestibule door at public hall, 1st story

    Oct 18, 2006

    Closed — Violation closed
  • B

    Properly repair the broken or defective window frame in the entire apartment located at apt 3, 3rd story, apartment at west

    Oct 18, 2006 · Apt 3

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color ceiling in the 3rd room from east located at apt 3, 3rd story, apartment at west

    Oct 18, 2006 · Apt 3

    Closed — Violation closed
  • B

    M/d law abate the nuisance consisting of evidence of water leak at the west wall in the kitchen located at apt 3, 3rd story, apartment at west

    Oct 18, 2006 · Apt 3

    Closed — Violation closed
  • B

    Repair the roof so that it will not leak at ceiling in the 3rd room from east located at apt 3, 3rd story, apartment at west

    Oct 18, 2006 · Apt 3

    Closed — Violation closed
  • B

    Properly repair the broken or defective light fixture at public hall, 2nd story

    Oct 18, 2006

    Closed — Violation closed
  • B

    Provide adequate light of not less than 60 watts incandescent or equivalent illumination , at public hall, 2nd story

    Oct 11, 2006

    Closed — Violation closed
  • C

    Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system .. at public hall, 1st story

    Oct 3, 2006

    Closed — Violation closed
  • B

    Provide adequate light of not less than 60 watts incandescent or equivalent illumination at ceiling at public hall, 2nd story

    Oct 3, 2006

    Closed — Violation closed
  • A

    Refit entrance door to building , 1st story

    Sep 28, 2006

    Closed — Violation closed
  • B

    M/d law abate the nuisance consisting of evidence of leak at ceiling from bathroom above in the bathroom located at apt 2fl, 2nd story, 1st apartment from south at west

    Aug 29, 2006 · Apt 2FL

    Closed — Violation closed
  • A

    Refit the door the at front entrance located at apt 1, 1st story, 1st apartment from south at west

    Aug 14, 2006 · Apt 1

    Closed — Violation closed
  • B

    Repair the leaky and/or defective faucets at sink in the kitchen located at apt 1, 1st story, 1st apartment from south at west

    Aug 14, 2006 · Apt 1

    Closed — Violation closed
  • B

    Repair or replace the smoke detector defective in the entire apartment located at apt 1, 1st story, 1st apartment from south at west

    Aug 14, 2006 · Apt 1

    Closed — Violation closed
  • B

    Abate the nuisance consisting of vermin roaches in the entire apartment located at apt 1, 1st story, 1st apartment from south at west

    Aug 14, 2006 · Apt 1

    Closed — Violation closed
  • C

    Provide hot water at all hot water fixtures in the entire apartment located at apt 1, 1st story, 1st apartment from south at west

    Aug 14, 2006 · Apt 1

    Closed — Violation closed
  • A

    Section 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor at vestibule at public hall, 1st story

    May 26, 2006

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the 2nd room from east located at apt 2fl, 2nd story

    Apr 24, 2006 · Apt 2FL

    Closed — Violation closed
  • B

    Properly secure the loose electrical light fixture at ceiling in the 3rd room from east located at apt 2fl, 2nd story

    Apr 24, 2006 · Apt 2FL

    Closed — Violation closed

DOB building violations · 0

No DOB violations on record

ECB violations · 1

  • Hazardous

    Failure to maintain bldg: defects noted 1. no lights in public hallways throughout w/front entry and vestibule doors opened 2. window, adjacent to entry door to bldg for vacant apt opened leaving free access to

    Aug 20, 2007 · Penalty $2,500

    Resolve

Complaints

  • Heating

    Heat related

    Jan 25, 2011 · Apt BLDG

    Close
  • Electric

    Electric-supply

    May 27, 2007 · Apt 3

    Close
  • Plumbing

    Toilet

    Mar 23, 2007 · Apt 3

    Close
  • Electric

    Lighting

    Mar 23, 2007 · Apt 3

    Close
  • Electric

    Lighting

    Mar 23, 2007 · Apt 3

    Close
  • Heating

    Heat related

    Mar 23, 2007 · Apt 3

    Close
  • Plumbing

    Water supply

    Feb 13, 2007 · Apt 3

    Close
  • Heating

    Heat related

    Feb 13, 2007 · Apt 3

    Close
  • General

    Windows

    Feb 6, 2007 · Apt 3

    Close
  • Plumbing

    Water supply

    Feb 6, 2007 · Apt 3

    Close
Show 40 more ↓
  • Electric

    Wiring

    Feb 6, 2007 · Apt 3

    Close
  • Electric

    Electric-supply

    Feb 6, 2007 · Apt 3

    Close
  • Heating

    Heat related

    Feb 6, 2007 · Apt 3

    Close
  • Heating

    Heat related

    Feb 6, 2007 · Apt 3

    Close
  • Heating

    Heat related

    Dec 27, 2006 · Apt 2FL

    Close
  • Heating

    Heat related

    Dec 27, 2006 · Apt 2FL

    Close
  • Electric

    Electric-supply

    Dec 26, 2006 · Apt 1FL

    Close
  • Electric

    Electric-supply

    Dec 26, 2006 · Apt 1FL

    Close
  • Heating

    Heat related

    Dec 26, 2006 · Apt 1FL

    Close
  • Electric

    Lighting

    Dec 25, 2006 · Apt 2FL

    Close
  • Electric

    Lighting

    Dec 25, 2006 · Apt 2FL

    Close
  • Heating

    Heat related

    Dec 25, 2006 · Apt 2FL

    Close
  • Heating

    Heat related

    Dec 19, 2006 · Apt 2FL

    Close
  • Heating

    Heat related

    Oct 31, 2006 · Apt 3

    Close
  • Heating

    Heat related

    Oct 30, 2006 · Apt 3

    Close
  • Plumbing

    Water-leaks

    Oct 17, 2006 · Apt 3

    Close
  • Plumbing

    Water-leaks

    Oct 17, 2006 · Apt 3

    Close
  • Paint/plaster

    Ceiling

    Oct 17, 2006 · Apt 3

    Close
  • Heating

    Heat related

    Oct 17, 2006 · Apt 3

    Close
  • Electric

    Lighting

    Oct 17, 2006 · Apt 3

    Close
  • Electric

    Lighting

    Oct 17, 2006 · Apt 3

    Close
  • Paint/plaster

    Ceiling

    Oct 12, 2006 · Apt 3

    Close
  • Plumbing

    Water-leaks

    Oct 12, 2006 · Apt 3

    Close
  • Plumbing

    Water-leaks

    Oct 12, 2006 · Apt 3

    Close
  • Electric

    Electric-supply

    Oct 11, 2006 · Apt 3

    Close
  • Paint/plaster

    Ceiling

    Oct 11, 2006 · Apt 3

    Close
  • Plumbing

    Water supply

    Oct 11, 2006 · Apt 3

    Close
  • Electric

    Lighting

    Sep 27, 2006 · Apt 3

    Close
  • Heating

    Heat related

    Sep 27, 2006 · Apt 3

    Close
  • Electric

    Lighting

    Sep 26, 2006 · Apt 2FL

    Close
  • Heating

    Heat related

    Sep 26, 2006 · Apt 2FL

    Close
  • Heating

    Heat related

    Aug 27, 2006 · Apt 2FL

    Close
  • Heating

    Heat related

    Aug 11, 2006 · Apt 1

    Close
  • Plumbing

    Water supply

    Aug 10, 2006 · Apt 2FL

    Close
  • General

    Windows

    May 24, 2006 · Apt 3

    Close
  • Heating

    Heat related

    May 24, 2006 · Apt 3

    Close
  • Heating

    Heat related

    May 24, 2006 · Apt 2FL

    Close
  • Heating

    Heat related

    Apr 20, 2006 · Apt 2FL

    Close
  • Appliance

    Refrigerator

    Apr 4, 2006 · Apt 2FL

    Close
  • General

    Mold

    Apr 4, 2006 · Apt 2FL

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C0)
Year built
1899
Floors
3
Residential units
3
Building area
2,400 ft²
Lot area
1,758 ft²
Zoning
R4
Community board
305
Council district
37
Block / lot
3486 / 30
Assessed value
$56,040
Landmark / historic district
No

HPD registration #327068, last renewed Nov 17, 2025.

Questions about 28 Vermont Street

Who owns 28 Vermont Street?

The owner of record in NYC Department of City Planning PLUTO data is Sosa, Luis Antonio.

Does 28 Vermont Street have violations?

Yes. NYC HPD has recorded 150 housing violations at this property.

Is 28 Vermont Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 28 Vermont Street built?

City records list 1899 as the year it was built.

How many apartments are in 28 Vermont Street?

It has 3 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.