roofy

290 St Nicholas Avenue

Brooklyn, NY 11237BBL 3-03329-0016Map

Owner of record: St Brigids Rc3ch

290 St Nicholas Avenue is a religious facility built in 1909 in Brooklyn, 11237. The owner of record is St Brigids Rc3ch. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
19
ECB violations
11
HPD complaints
3

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 19

  • Immediate emergency anythingoptional

    Install approximately 16 linear feet of sidewalk shed along front expo sure one over the front entrance doors and sidewalk. the sidewalk shed shall wrap around exposure 4, providing additional protection at 404 grove street side yard an additional 16 linear feet

    Jul 22, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2020 external low pressure inspection

    Jun 30, 2023

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 15, 2017

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Lblvio-low pressure boiler boiler required

    Dec 31, 2009

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Jun 26, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 31, 2005

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
Show 9 more ↓
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jul 25, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jul 25, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jul 25, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 1, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 16, 1993

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 1, 1993

    Dob violation - dismissed

ECB violations · 11

  • Class - 1

    Observed facade at all exposure in state of disrepair. missing mortar at various locations and section of bricks have fallen off at various locations as well. creating a hazardous condition for kids and adults

    Jul 22, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    Hb smith steam boiler has incorrect safety valve discharge pipe+is missing body drain pipe+power flame burner gas piolit is not hard pipe to regulator+ao smith gas hwh has incorrectly installed spill switch+has

    Jun 18, 2025

    Resolve
  • Class - 2

    Exit door not self-closing.noted the exterior foor inside classroom 101 and the kitchen exit 3 doors are not closing properly creating a hazardous condition in the event of a fire.remedy:repair/repalce door.

    Mar 14, 2023 · Penalty $1,562

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner:illumination forexits,exit discharges and public corridors per bc1006.1;27-381.noted the exit sign on 1st floor level room 101 is inoperable when tested.rem

    Mar 14, 2023 · Penalty $655

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner.lack of emergency lighting for exits,exit discharges and public corridors per bc1006.1at the time of inspection observed that both upk on the 3rd and 4th fl

    Apr 13, 2022 · Penalty $6,250

    Active
  • Class - 1

    Failure to provide use lifeline while working on scaffold. premises under alt2 job #321556856 loc folder. at time of inspection found:bldgapprx 50'in higher installed pipe scaffolding and construction worker,

    Aug 23, 2017 · Penalty $1,600

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner. at boiler room ceiling: concrete spalling w/exposed rusted rebar. remedy: repair concrete ceiling.

    May 29, 2015 · Penalty $250

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner: no fire stopping per bc 712.3;27-345 no fire stopping at penetrations in boiler room at electrical conduit & also at 1st fl entry foyer. remedy: provide/mainta

    May 29, 2015 · Penalty $250

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner: use of prohibited door hardware per bc 1008.1.8;27-371(j) use of mechanical door stops atentry doors & at fire stair doors on all floors (stair a & b exits 1,2

    May 29, 2015 · Penalty $250

    Resolve
  • Class - 2

    B254,10a,10b,25a,25b,32a,50a,50b,50c,50d. 50a safety or relief valve leaking. 50b cooks frozen. 50c fire chamber brick walls defective. 50d holes in boiler room ceiling and walls.

    Oct 21, 2008

    Resolve
Show 1 more ↓
  • Class - 3

    B354,36,34b,50a. 50a boiler room not a storage room.

    Oct 21, 2008 · Penalty $200

    Resolve

Complaints

  • Safety

    Window guard broken/missing

    Dec 8, 2025 · Apt 307

    Close
  • Heat/hot water

    Apartment only

    Feb 17, 2020 · Apt 1

    Close
  • Heat/hot water

    Apartment only

    Feb 14, 2020 · Apt 1

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Religious facility (M9)
Year built
1909
Floors
3
Residential units
—
Building area
87,000 ft²
Lot area
48,500 ft²
Zoning
R6
Community board
304
Council district
37
Block / lot
3329 / 16
Assessed value
$3,783,600
Landmark / historic district
No

Questions about 290 St Nicholas Avenue

Who owns 290 St Nicholas Avenue?

The owner of record in NYC Department of City Planning PLUTO data is St Brigids Rc3ch.

Does 290 St Nicholas Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 290 St Nicholas Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 290 St Nicholas Avenue built?

City records list 1909 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.