196 Stanhope Street
Brooklyn, NY 11237BBL 3-03268-0032Map
Owner of record: Stanhope Real Estate Development LLC
196 Stanhope Street is an elevator apartment building built in 2024 in Brooklyn, 11237. It has 10 residential units across 5 floors. The owner of record is Stanhope Real Estate Development LLC. HPD has recorded 2 housing violations here, most recently on January 2, 2011. 2 of the 2 most recent violations are still open.
- HPD violations
- 2
- DOB violations
- 1
- ECB violations
- 20
- HPD complaints
- 19
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 2
- BHazardous
Discontinue unlawful cooking space or file plans and application with this department to legalize same, if lawfully feasible at kitchen in the entire apartment located at bsmt-apt bb
Jan 2, 2011 · Apt BB
Open — Nov sent out - BHazardous
Discontinue use of rooms for living, disconnect plumbing fixtures where illegal and properly seal pipe connections kitchen and bathroom in the entire apartment located at bsmt-apt bb
Jan 2, 2011 · Apt BB
Open — Nov sent out
DOB building violations · 1
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 15, 2011
Dob violation - dismissed
ECB violations · 20
- Class - 1
Failure to maintain adequate housekeeping per section requirement. as noted: at time of inspection at an active jobsite of a proposed 5 story building already @ the bulkhead level inside the building at the 1st
Aug 13, 2025 · Penalty $2,500
Resolve - Class - 1
Failure to institute/maintain safety equipment measures/temporary construction "no handrail". as noted: at time of inspection at an active jobsite of a proposed 5 story building already at the bulkhead level. o
Jul 7, 2025 · Penalty $2,500
Resolve - Class - 1
Failure to maintain adequate housekeeping per section requirement. as noted: at time of inspection at an active jobsite of a proposed 5 story building already at the bulkhead level. inside the building from the
May 15, 2025 · Penalty $6,250
Resolve - Class - 1
Failure to institute/maintain safety equipment measures/temporary construction "no guardrail". as noted: at time of inspection at an active jobsite of a proposed 5 story building already at the bulhead level, o
May 15, 2025 · Penalty $6,250
Resolve - Class - 2
Responding a complaint observed: outrigger suspended scaffold in place at expo# 4 contrary to code. upon review department record it appears, no notification for outrigger suspended scaffold, creating an unsafe
May 8, 2025 · Penalty $2,500
Resolve - Class - 2
Bc 3314.3.4 at time of inspection observed: suspended scaffold at expo# 4 resting on top of supported scaffold installed on roof of adjoining property, upon asking for imposed load letter none was provided, cre
May 8, 2025 · Penalty $1,250
Resolve - Class - 2
At time of inspection observed: suspended scaffold at expo# 4 contraryto approved drawings. eq-101.00 : inadequate/missing additional tiebacks on outrigger angled beams also tie backs are in opposite angle not
May 8, 2025
Resolve - Class - 2
Observed pipe scaffold at exposure 1 set back (4th floor), and roof level bulkhead in an unsafe condition. scaffold is missing proper planking, handrails, and condition poses a serious fall hazard for personne
Feb 24, 2025 · Penalty $2,500
Resolve - Class - 2
Observed unenclosed edges at roof level, and exp1. missing handrails, and guardrails. these unsafe conditions are a hazard to construction site and can cause serious injury from fall where there are no temp gua
Feb 24, 2025
Resolve - Class - 2
Observation: violating condition observed. @ exposure#1 failure to comply with d.o.t requirements for porter potty obstructing pedestrian walkway a minimum of 5 feet is required. @ exposure#1 failure to protect
Dec 24, 2024 · Penalty $625
Resolve
Show 10 more ↓
- Class - 2
No en drawing approved from dob provided on the job site at the time of inspection., maintain/display required documents; please go to https://www1.nyc.gov/site/buildings/codes/energy-conservation-code.page and
Dec 12, 2024 · Penalty $3,125
Resolve - Class - 1
At time of inspection observed: active job site concrete operations in progress. sidewalk and completed closed occupied, no flaggers to protect pedestrians no barriers as per site safety plan creating a potenti
Nov 27, 2024 · Penalty $1,250
Resolve - Class - 2
At time of inspection observed: concrete operations at 3rd fl. level contractor failure to perform proper concrete washout water procedures. no concrete wash-out box provided, creating an unsafe and environment
Nov 27, 2024 · Penalty $2,500
Resolve - Class - 1
At time of inspection observed: concrete work in progress at 3rd fl. level. inadequate/no roof protection for adjacent occupied buildings exposure# 2/4. creating o safety hazardous condition materials, debris c
Nov 27, 2024 · Penalty $5,000
Resolve - Class - 1
At time of inspection observed: active work at 3rd fl. level in progress, no overhead protection for adjoining properties at rear corner exposure 2/3/4. debris throughout. when materials, tools, debris fall, be
Nov 27, 2024 · Penalty $10,000
Resolve - Class - 1
At time of inspection observed: active job site concrete operation in progress. no guardrails, no control access zone throughout at open perimeters. creating a potential fall hazardous condition. stop all work
Nov 27, 2024 · Penalty $5,000
Resolve - Class - 2
Atoi observed foundation with outboard insulation was installed for 5 stories building requested approved plans not provided., maintain/display required documents; provide all approved plans on site .https://ww
Oct 17, 2024 · Penalty $1,250
Resolve - Class - 2
Observed construction fence installed not maintained viewing panel broken missing at exp#1 and graffiti all over the construction fence.
Sep 23, 2024 · Penalty $1,000
Resolve - Class - 1
Failure to comply with the commissioner's order in dob violation vio23-00587,dated 3/2/2023.respondent was required to submit an engineer's report concerning structurally deficient conditions.as of 10/11/2023,a
Oct 11, 2023 · Penalty $2,500
Resolve - Class - 1
Occupancy contrary to that allowed by cofo & dob records,class'a' apt created @ bsmt partitions erected creating rooms fixtures present.rem:discontinue illegal use of amended cofo
Jan 2, 2011 · Penalty $2,400
Resolve
Complaints
- Heating
Heat related
Dec 25, 2010 · Apt 1
Close - Heating
Heat related
Jan 6, 2010 · Apt 2FL
Close - General
Ceramic-tile
Jan 6, 2010 · Apt 2FL
Close - General
Windows
Jan 6, 2010 · Apt 2FL
Close - Paint/plaster
Wall
Jan 6, 2010 · Apt 2FL
Close - Heating
Heat related
Jan 4, 2010 · Apt 2FL
Close - Heating
Heat related
Dec 22, 2009 · Apt 2FL
Close - Heating
Heat related
Dec 19, 2009 · Apt 2FL
Close - Heating
Heat related
Dec 13, 2009 · Apt 2FL
Close - General
Windows
Dec 13, 2009 · Apt 2FL
Close
Show 9 more ↓
- Plumbing
Bathtub/shower
Dec 13, 2009 · Apt 2FL
Close - Paint/plaster
Wall
Dec 13, 2009 · Apt 2FL
Close - General
Windows
Dec 13, 2009 · Apt 2FL
Close - Heating
Heat related
Feb 19, 2006 · Apt 2FL
Close - Heating
Heat related
Feb 13, 2006 · Apt 2FL
Close - Heating
Heat related
Dec 27, 2005 · Apt 2FL
Close - Heating
Heat related
Dec 27, 2005 · Apt 2FL
Close - Heating
Heat related
Dec 23, 2005 · Apt 2
Close - Heating
Heat related
Dec 16, 2005 · Apt 2
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D3)
- Year built
- 2024
- Floors
- 5
- Residential units
- 10
- Building area
- 16,542 ft²
- Lot area
- 2,000 ft²
- Zoning
- C4-3
- Community board
- 304
- Council district
- 37
- Block / lot
- 3268 / 32
- Assessed value
- $555,300
- Landmark / historic district
- No
Questions about 196 Stanhope Street
Who owns 196 Stanhope Street?
The owner of record in NYC Department of City Planning PLUTO data is Stanhope Real Estate Development LLC.
Does 196 Stanhope Street have violations?
Yes. NYC HPD has recorded 2 housing violations at this property.
Is 196 Stanhope Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 196 Stanhope Street built?
City records list 2024 as the year it was built.
How many apartments are in 196 Stanhope Street?
It has 10 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.