360 Johnson Avenue
Brooklyn, NY 11206BBL 3-03074-0023Map
Owner of record: Chesse Smokers INC
360 Johnson Avenue is a hotel built in 2017 in Brooklyn, 11206. The owner of record is Chesse Smokers INC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 4
- ECB violations
- 32
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 4
- Construction other optional
C-construction other optional
Aug 29, 2019
Vp*-violation unserved ecb- dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 31, 2018
Dob violation - dismissed - Construction other optional
Stop all work immediately make the site safe only contact borough comm . office at 718 802-3677 for info
Oct 12, 2017
Dob violation - dismissed - Construction other optional
C-construction other optional
Feb 11, 2009
Dob violation - dismissed
ECB violations · 32
- Class - 1
Sec. 3314.4.8 failure to maintain scaffold as per code subsection. at time of inspection on an active jobsite,observed work in progress w/2 workers performing work on 2 scaffolds erected at 1st fl level & 1st
Aug 29, 2019 · Penalty $2,500
Resolve - Class - 2
Scaffold training certificate card not readily available for inspection. at time of inspection on an active jobsite,observed work in progress on 2 scaffolds erected on ground floor & staircase to cellar. upon
Aug 29, 2019
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temporary construction-no guardrails. at time of inspection on an active jobsite,observed guardrails missing at elevator shaft unprotected opening. als
Aug 29, 2019 · Penalty $2,500
Resolve - Class - 1
Failure to provide overhead protection(ohp). at time of inspection on an active jobsite,observed that no overhead protection was provided atexp#1,2&4. work in progress w/roof pavers installation at 2nd roof lev
Aug 29, 2019
Resolve - Class - 1
Failure to maintain adequate housekeeping per section requirements. attime of inspection on an active jobsite,observed inadequate housekeeping consisting of large amounts of debris & construction combustible
Aug 29, 2019 · Penalty $2,500
Resolve - Class - 1
Ladder on jobsite modified,not to manufacturer specifications at the time of my inspection of a 6 sty n/b work in progress,i observed a ladder w/scrap metal adhered to side to keep it in an open position. this
Jul 24, 2018 · Penalty $2,500
Resolve - Class - 1
Sec. 27-1018 inadequate storage of materials. at the time of my inspection of a 6 sty,nb,work in progress,i observed storage of loose misc-pipes & material near the edge of the bldg. the material was not blocke
Jul 24, 2018 · Penalty $625
Resolve - Class - 1
Sec. 1019.1.7;1022.8 no signage numbering floors @ stairways. at the time of my inspection on a 6 sty,nb work in progress,i observed that no floors had any signs indicating what floor your on. also no fire esti
Jul 24, 2018
Resolve - Class - 1
Sec. 3303.8 standpipe. at time of inspection of nb currently at bulkhead level which is at 106'-0" & 6th fl at 83'-0" obstructed no standpipe in entire bldg. stop all work above 75'=0" at interior of bldg excep
Jul 24, 2018 · Penalty $2,500
Resolve - Class - 1
Standing water 3" & mole in sub-cellar. at the time of my inspection of a 6 sty,n/b work in progress,i observed in the sub-cellar more then 3" of standing water. standing water creates a health hazard as a brea
Jul 24, 2018 · Penalty $625
Resolve
Show 22 more ↓
- Class - 1
Sec. 3314.4.3.3 no installation inspection for supported scaffold on site upon my inspection of a 6 sty new bldg work in progress. i observed supported scaffold @ exp#1,2&4 w/various planks not tied down nets
Jul 24, 2018 · Penalty $2,500
Resolve - Class - 1
Sec. 3301.7 no elevator shaft platform drawings. at the time of my inspection of a 6 sty,n/b work in progress. i observed many platforms built on a make shift planks & no d.d. this occurs on a mininum of 3 sepe
Jul 24, 2018 · Penalty $2,500
Resolve - Class - 1
Sec. 3301.2 failure to safeguard,miantain ladder at the time of my inspection if a 6 sty,n/b work in progress. i observed a jobsite ladder built leaning to the uppoer level which wasnt isnt tied off could creat
Jul 24, 2018
Resolve - Class - 2
Jobsite fence not maintained. at the time of my inspection of a 6 sty n/b work in progress. i observed the fence poorly maintained,numerous bills,spray paint & not painted in the hunter green designated color
Jul 24, 2018
Resolve - Class - 1
No hoist in building. at time of my inspection of a 6story n/b work inprogress, i noticed there is no hoist installed in building. the roof has been topped off and the bulkhead is at apprx 106: code states bldg
Jul 24, 2018 · Penalty $625
Resolve - Class - 1
Sec. 3301.7 no fence documents on site. at the time of my inspection of a 6 sty nb work in progress,i observed fence in serious disarray. the fence was not plumb,the vision panels were all covered up w/plywood
Jul 24, 2018 · Penalty $625
Resolve - Class - 1
Inadequate superintendents log book,upon my inspection of a 6 sty,nb work in progress,i asked to see the superintendents daily log book. upon observation,i noticed a lack of information. 1)no list of general
Jul 24, 2018 · Penalty $10,000
Resolve - Class - 1
Unprotected holes in floor. at the time of my inspection of a 6 sty,nb work no progress,i observed on many floors,holes in the floor-next tothe hvac duct work,& in some areas 5" core holes in the middle of the
Jul 24, 2018 · Penalty $2,500
Resolve - Class - 1
Failure to safeguard all persons & property affected by construction operations-scaffold. at the time of my inspection on a 6 sty n/b work in progress,i noticed from the street level now the vertical netting is
Jul 24, 2018 · Penalty $10,000
Resolve - Class - 1
Sec. 3307.2.6 temporary walkway not 5' as required. at the time of my inspection of a 6 sty n/b work in progress,i observed an unclear path for egress between sws & the yodlocks. this creates a potential hazard
Jul 24, 2018 · Penalty $2,500
Resolve - Class - 1
Sec. 3301.2 inadeqaute means of egress-stair inlays. at the time o my inspection of a 6 sty n/b work in progress. i observed the wood used to infill stairs was inadequate & consisting of wood pieces being short
Jul 24, 2018 · Penalty $1,250
Resolve - Class - 1
Guardrail system-inadequate failure to comply at the time of my inspection of a 6 sty n/b work in progress,i observed inadequate guardrail at multiple locations throughout bldg & elevator shaft,windows & balcon
Jul 24, 2018 · Penalty $2,500
Resolve - Class - 1
Sec. 3308.5 vertical safety netting shall be installed & maintained tocover all unenclosed perimeters,to maintain safe operations. at the time of my inspection of a 6 sty n/b work in progress. i observed in ade
Jul 24, 2018
Resolve - Class - 1
Sec. 3314.4.3.1;3314.5.1 supported scaffold has been modified,allowing holes,gaps on working platforms. at the time of my inspection of a 6 sty n/b work in progress,i observed the supported scaffold has been
Jul 24, 2018 · Penalty $2,500
Resolve - Class - 1
Sec. 3303.16 contractor sheds are made of combustible material upon my inspection of a 6 sty,nb work in progress,i observed on the 1st fl 5 sheds made of combustible materials & w/i 30' of one another. the comb
Jul 24, 2018 · Penalty $625
Resolve - Class - 1
Sec. 3307.4.3 failure to safeguard public at the time of inspection ofa 6 sty,nb work in progress. i observed yodlocks in the street that are empty allowing them to blow in the wind or be moved causing traffic
Jul 24, 2018 · Penalty $625
Resolve - Class - 1
Sec: bc3309.10. inadequate roof protection adjoining property. @ time of insp of a 6 story nb @ steel erecting 5th flr observed inadequate roof protection of adj property @ exp#3. there is 12ft of protection &
Jun 21, 2017
Resolve - Class - 1
Sec: bc3301.1.2. failure to comply w/ nyc fire code- no fire watch @ time of insp of 6 story nb @ steel erection on 5 flr observed 2 welders& 1 worker burning steel & no fire watch persons on site. code require
Jun 21, 2017
Resolve - Class - 1
Sec: bc 28-407.1. failure to have welders license for manual structural welding. @ time of insp of 6 story nb @ steel erected 5th flr observed a worker welding heavy structural steel on 4th flr upon request to
Jun 21, 2017 · Penalty $400
Resolve - Class - 2
Bc3303.2.1:dot premit to place crane on street expd.note:at time of inspection complaint,noticed leadway closed w/crane on street.dot permit on site expd 3/9/17 for occupying roadway w/crane.rem:remnew dot perm
May 23, 2017
Resolve - Class - 1
3309.6 failure to monitor adjoining structures for movement in all directions during excavation-related activity that may adversely affect adjoining structures.@the time of inspection it was observed that excav
Jun 14, 2016 · Penalty $1,600
Resolve - Class - 1
Failure to notify dob within 24-48 hrs of the start of excavation.@thetime of inspection it was observed that excavation operation was ongoing &there was no notification to dob on file.rem:officially notify dob
Jun 14, 2016 · Penalty $1,200
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Hotel (H3)
- Year built
- 2017
- Floors
- 6
- Residential units
- —
- Building area
- 24,624 ft²
- Lot area
- 7,470 ft²
- Zoning
- M1-2
- Community board
- 301
- Council district
- 34
- Block / lot
- 3074 / 23
- Assessed value
- $4,021,200
- Landmark / historic district
- No
HPD registration #391587, last renewed Jul 23, 2025.
Questions about 360 Johnson Avenue
Who owns 360 Johnson Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Chesse Smokers INC.
Does 360 Johnson Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 360 Johnson Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 360 Johnson Avenue built?
City records list 2017 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.