roofy

208 Montrose Avenue

Brooklyn, NY 11206BBL 3-03063-0006Map

Owner of record: Meta-K Partners, LLC

208 Montrose Avenue is a two-family home built in 1920 in Brooklyn, 11206. It has 2 residential units across 2 floors. The owner of record is Meta-K Partners, LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
10
ECB violations
21
HPD complaints
4

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 10

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 23, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 23, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 23, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 23, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 7, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 7, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 7, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 7, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 7, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 7, 2019

    Dob violation - dismissed

ECB violations · 21

  • Class - 2

    At time of inspection observed expired construction fence at exposure #1 as of 2/28/2024 permit #321629190-eq-fn.

    Jun 25, 2024 · Penalty $1,250

    Resolve
  • Class - 2

    Active construction site, work at superstructure phase, approximately 10 to 20 feet higher then adjacent building, it is noticed that the roof protection system to the adjacent building were not installed at ex

    Nov 16, 2022 · Penalty $1,280

    Active
  • Class - 2

    Active construction site, work at superstructure phase, observed the sidewalk shed at exp#1, reviewing the plans and field it was noticed that the five feet makeshift catch on sidewalk shed is erected without t

    Nov 16, 2022 · Penalty $6,250

    Active
  • Class - 1

    Documents to be kept on site. at the time of my inspection at a 5 sty bldg under construction,i observed ramp that was used to move material from 1st fl to basement & back yard upon request for design drawings

    Sep 23, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Sec. 3304.3 housekeeping. at the time of my inspection at a 5 sty bldgunder construuction,i observed inadequate housekeeping. construction material,debris & garbage scatter on the 1st fl & basement. also w/all

    Sep 23, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Inadequate guardrails. at the time of my inspection at a 5 sty bldg under constrction,i observed inadequate guardrails on 1st fl. they were incomplete & had the wrong netting. improper guardrails systems create

    Sep 23, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Sec. 28-105.12.2 work does not conform to approved design drawings/plans. at the time of my inspection at a 5 sty bldg under construction,i observed concrete,columns erected on bsement after reviewing approved

    Sep 23, 2020 · Penalty $2,500

    Active
  • Class - 2

    3301.9.1.4 project information panel specification. note:at the time of inspection of non active job-site,i observed the information panel was not display on construction fence. remedy:provide and maintain adeq

    Sep 24, 2019

    Resolve
  • Class - 2

    Jobiste fence not cosnrtcuted or maintained purusnat to subsection at the time of inspection i observed construction fence at exposure 1 on had in picture posting and grafitti on fence construction fence should

    Sep 20, 2019

    Resolve
  • Class - 2

    Prject information panel.sidwlak shed parapet panel construction sign not provided or not in compliance with setcion at the time of inspection i observed construction fence of exposure 1 without any information

    Sep 20, 2019

    Resolve
Show 11 more ↓
  • Class - 1

    Bc3301.6. temporary platform (no design drawing). @ the time of my insp on an active jobsite i observed @ exp. #3 a temporary platform was built for use of equipment, material, site personnel, site debris & the

    May 8, 2019 · Penalty $1,250

    Active
  • Class - 1

    Protection of sides @ excavation, sheeting/shoring/bracing (soe for more than 5'). @ the time of insp on an active jobsite i observed @ exp.#3 in a dept of more than 5' excavation was being done & the use of a

    May 8, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Bc3309.16 failure to monitor adjoining properties (bldg attached). @ the time of insp on an active jobsite i observed 50% of the bldg was demolished with excavation & pile driving being done @ exp. # 3 rear yar

    May 8, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to provide osha traiding @ the time of my insp on an active jobsite of a proposed 5 story bldg permit holder failed to ensure each workers successfully completed the required training under bc3321.1 i o

    May 8, 2019 · Penalty $312

    Resolve
  • Class - 1

    Sec. 3309.9 weatherproof adjoining properties. at the time of my inspection on an active jobsite. i observed permit holder failed to adequately weatherproof adjoining properties at the rear yard of exp#2&4 as

    May 8, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Work does not conform to approved site safety plan(heavy duty compresser,large electrical transformer on site). at the time of my inspectionon an active jobsite. i observed on the 1st fl of the bldg a large com

    May 8, 2019 · Penalty $625

    Active
  • Class - 1

    Bc3310.3 failure to provide site safety plan (plan inadequate) at thetime of my inspection on an active jobsite, i observed demolition was partially done on the building (2 floors existing) removal of partitio

    May 8, 2019 · Penalty $625

    Resolve
  • Class - 1

    Bc3309.4.2. support of party walls. @ the time of my insp on an activejobsite i observed to rear yard of exp. #2 party wall separating both properties was being removed w/o any laterial support to party wall be

    May 8, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to maintain adequate houskeeping per section required. @ the tim ef my insp on an active jobsite i observed on the 1st fl permit holder failed to maintain adequate houskeeping which consisted such items

    May 8, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to maintain/display on site docs required by bc chapter 33. @ the time of my insp on an active jobsite of a proposed 5 story bldg currently a 2 story bldg under an alt1 permit. bldg was @ 50% demolished

    May 8, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to provide osha traiding @ the time of my insp on an active jobsite of a proposed 5 story bldg permit owner failed to ensure each workers successfully completed the required training under bc3321.1 i ob

    May 8, 2019 · Penalty $312

    Resolve

Complaints

  • Plumbing

    Water supply

    May 23, 2007 · Apt 1

    Close
  • Heating

    Heat related

    Apr 21, 2007 · Apt 1

    Close
  • Heating

    Heat related

    Feb 17, 2007 · Apt 1

    Close
  • Heating

    Heat related

    Jan 26, 2005 · Apt 2

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Two-family home (B9)
Year built
1920
Floors
2
Residential units
2
Building area
1,520 ft²
Lot area
2,500 ft²
Zoning
R6
Community board
301
Council district
34
Block / lot
3063 / 6
Assessed value
$100,140
Landmark / historic district
No

Questions about 208 Montrose Avenue

Who owns 208 Montrose Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Meta-K Partners, LLC.

Does 208 Montrose Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 208 Montrose Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 208 Montrose Avenue built?

City records list 1920 as the year it was built.

How many apartments are in 208 Montrose Avenue?

It has 2 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.