What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 1
- Construction other optional
C-construction other optional
Mar 17, 1995
Vp*-violation unserved ecb- dismissed
ECB violations · 47
- Class - 2
During my inspection and upon reviewing dob now and bis system reveals ssm / ssc on multiple permits and nb not in compliance to code bc 3310.5.4 stop all work under application320625070-01-nb except to update
Apr 29, 2026 · Penalty $2,500
Resolve - Class - 2
Upon inspection i observed a shed installed at exposure 1&2 not no sidewalk shed info panel installed contrary to code 3301.9.2 sidewalk shed parapet information panel. i also observed a construction fence inst
Feb 3, 2026 · Penalty $1,250
Active - Class - 2
Upon inspection of an active 10 story nb construction site i observed a fence installed at expos 1&2 not constructed or maintained according to code. installed viewing panels were not 12x12 in size contrary to
Feb 3, 2026 · Penalty $1,030
Resolve - Class - 2
Upon inspection i observed a sidewalk shed installed at expos 1&2 not maintained contrary to code 3307.6.5.1 safe condition. un-protected bolts & tops of kickers along shed pathway (expo 1&2), rotting mudsills
Feb 3, 2026 · Penalty $2,430
Active - Class - 2
I observed a sidewalk shed installed at exposure 1&2 contrary to code. minimum 8ft height not maintained at corner of expos 1&2, pipes set below 8ft across pathway (3307.6.4.7 height). shed bracing and jersey b
Feb 3, 2026 · Penalty $2,430
Active - Class - 2
I observed a sidewalk shed installed at expos 1&2 and upon review of approved drawings it was determined the shed was installed contrary to the plans. missing double headers at all spans over 10ft. incorrect cr
Feb 3, 2026 · Penalty $1,280
Active - Class - 2
Bc3314.8.2 at time of inspection observed supported scaffold installed at exp# 1 3 4 not maintained as per code. debris netting loose / missing not securely fastened to the facade. stop all exterior work and us
Dec 22, 2025 · Penalty $5,000
Resolve - Class - 2
Bc3303.3 watchperson 10 story new building, building approximately 39,206 square feet. site closed and there were no construction activity. upon shouting at perimeter and banging on fence and door to alert watc
Dec 22, 2025 · Penalty $5,000
Resolve - Class - 2
At time of inspection observed construction fence installed at exp#1 2 not maintained as per code. multiple pieces of wood protruding from fence contrary to 3307.7.7 creating unsafe condition for pedestrians
Dec 22, 2025 · Penalty $2,500
Resolve - Class - 2
15 rcny 20-08 (b) at time of inspection observed: active job site, hydrant has been used. upon request for permit, none was provided. creating unsafe condition for safety monitoring and compliance. obtain permi
Oct 10, 2025 · Penalty $1,250
Resolve
Show 37 more ↓
- Class - 2
On active jobsite, observed section of sidewalk shed removed while exterior work is still being performed. makeshift over head protection has been installed in place of sidewalk shed. stop all exterior work exp
Oct 9, 2025 · Penalty $2,400
Resolve - Class - 2
Observed additional 1 story structure @ exposure 4 of jobsite. adjacent properties @ left has not been provided with roof protection and structure on right has no over head protection provided at common area. s
Oct 9, 2025 · Penalty $5,000
Resolve - Class - 2
On active jobsite, observed construction fence installed @ expo 4 rear yard of jobsite. sections of the construction fence are missing leading to common area of adjacent property. stop all work @ expo 4 of jobs
Oct 9, 2025 · Penalty $1,000
Resolve - Class - 2
Observation: model aparments on 3rd/4th floor being shown to perspective buyers. apartments were completely furnished. to get to model apts,perspective buyers has to walk thru a lobby under active construction
Jul 31, 2025 · Penalty $6,250
Active - Class - 2
No watchperson note: atoi of a 10-story new building 39,209 sq ft. site was closed with no construction activity. i shouted around the perimeter and banged on the fence/door to alert the watchperson and verify
May 24, 2025 · Penalty $5,000
Resolve - Class - 1
At time of inspection of 11 story nb that include approximately 4000 cubic yard of concrete. upon request for concrete safety manager none was provided and review of site safety manager logs none was mention or
Feb 28, 2025 · Penalty $2,530
Resolve - Class - 2
Bc3308.6.1.4 at time of inspection of 11 story new building during active construction site, upon inspection observed inadequate supported scaffold alternative in lieu of horizontal safety netting 3 stories bel
Feb 28, 2025 · Penalty $2,500
Resolve - Class - 2
Observed a multi-level steel structure in the process of being built at the roof level. review of the dob-approved structural plans showed that no such structure was reflected on said plans.. stop all structura
Sep 9, 2024 · Penalty $1,250
Resolve - Class - 2
Obsvd supported scaffold at the 9fl lvl at exps# 1&2 with inner legs of scaffold frames placed on the 9fl slab & the outer legs connected into the outer legs of the off-set scaffold section below- this conditio
Sep 9, 2024
Resolve - Class - 2
Bc 3303.7.7.2 standpipes. observed 9 str nb with one of the active standpipe risers not painted red- as required- at the 9th fl lvl. also- psi reading at top of standpipe and at street lvl reads aprox. 12 psi-
Sep 9, 2024 · Penalty $2,500
Resolve - Class - 1
Bc 3308.1 unenclosed perimeter protection. obsvd 9str nb with missing guardrails, vertical safety cable/netting system, or any other form of unenclosed perimeter protection in numerous accessible areas across m
Sep 9, 2024
Resolve - Class - 2
3301.5 unsafe conditions. any structure, temp construction installation, material, operation, or equipment found to be defective or unsafe, and posing a risk to public/property, shall be immediately secured & c
Jun 27, 2024 · Penalty $2,500
Resolve - Class - 2
3305.3.6.1.2 reshores in proximity to unenclosed perimeters. reshores within 10 ft (3048 mm) of an unenclosed perimeter of building shall be secured to prevent them from falling off building.observe reshoring a
Jun 27, 2024 · Penalty $2,500
Resolve - Class - 1
Observed inadequate housekeeping at flrs 1, 9 & roof consisting of excessive debris, materials & equipment laying on floors, blocking egress, creating a trip/fall hazard and unsafe work conditions for safe work
Jun 27, 2024 · Penalty $1,250
Resolve - Class - 1
3308.1- inadequate fall protection, missing netting and vertical safety cables at various locations. observed workers working on leading edge without proper fall protection. stop all work at leading edges and
Jun 27, 2024 · Penalty $5,000
Resolve - Class - 2
3301.1.2 fire code- observed diesel fueled gernerator at site exp #1 with out fdny permit. stop all use of generator. stop all use of generator and obtain permit.
Jun 27, 2024 · Penalty $625
Resolve - Class - 1
Observed no horizontal netting below unpoured/unstripped roof deck at exp.#2 as per indicated on engineer stamped plans. stop all work at exp. 2&3 corner + 20 ft back.
Jun 27, 2024 · Penalty $625
Resolve - Class - 2
3303.7.2 observed multiple locations througout site fire extinguishers are not maintained without pins and set on the floor of job site. maintain fire extinguishers as per code section fc 906: portable fire ex
Jun 27, 2024 · Penalty $625
Resolve - Class - 2
3301.1.1 responsibility for safety. observed hoist operator claudia rios operating jobsite hoist without training and certification. observed agapita lozano and javier trejo without adequate sst cards as per 3
Jun 27, 2024 · Penalty $1,250
Resolve - Class - 1
9 str nb-topped off, w/2-car material/personnel hoist instld & operational at exp#1. obsvd 2fl middle hoist tie in/anchor w/1 bolt missing on both sides of anchor, contrary to aprvd plan, & 9fl anchor attached
Jun 27, 2024 · Penalty $2,500
Resolve - Class - 2
At time of inspection observed: equipment, materials storage on top of sidewalk shed at exposure# 1 corner with exposure# 4 contrary to bc 3307.6.4.2.2 creating an unsafe condition for pedestrians if not in com
May 2, 2024 · Penalty $2,400
Resolve - Class - 2
At time of inspection observed: exposure# 1 equipment for form work on street unattended/inadequate storage zone completely open and easy access for pedestrians. contrary to bc 3307.4.7. creating unsafe conditi
May 2, 2024 · Penalty $2,400
Resolve - Class - 1
Bc3301.1.1 fail to institute fall protect safety measures.@9 story new building site in response to incident where worker injured from fall approx.9ft into large floor opening to floor below during floor cover
Dec 6, 2023
Resolve - Class - 2
Pedestrian protection does not meet code specification at the time of inspection construction site was closed and inactive.as per perimeter inspection i observed exposure#1,public sidewwalk/walkway did not have
Feb 24, 2022 · Penalty $2,400
Resolve - Class - 2
Pedestrian protection does not meet code specifications.at time of inspection observed a construction fence in place occupying the sidewalk on stewart avenue.d.o.t(dept of transportation)permits were provided t
Nov 18, 2021 · Penalty $625
Resolve - Class - 2
Jobsite fence not maintained.at time of inspection of 9 story new building at (glade) level with no construction activities observed construction fence not maintained as required painted with graffitti and cust
Sep 15, 2021
Resolve - Class - 2
Work w/o a permit(construction plywood fence permit expired).as noted @time of insp const site was closed.const plywood fence permit has expired on 7/2/19 permit #320625070-01-eq-fn.rem:comply w/code.renew cons
Aug 15, 2019
Resolve - Class - 2
Failure to safeguard all person 7 property affected by construction. at inspection time observed a construction site fence fallen down at exp#1 observed the stwsart st sidewlk is blocking & forcing the pedestri
Feb 26, 2019
Resolve - Class - 1
Prohibited outdoor ad. co(oac) sign on sidewalk shed or construction fence. observed several advertising sign various location. one sign reads "are you happy now" under it other "zedd elley duhe" 2nd reads you
Oct 20, 2018 · Penalty $625
Resolve - Class - 2
Failure to post or properly post permit for work at premises.noted:at time of this inspection,no any post were posted all around the fence/no permit posted.rem:pos/properly post permits
Oct 20, 2018 · Penalty $312
Resolve - Class - 1
Bc3301-2 failure to safeguard all persons. observed outside and insidejob site a household debris has been dumped. remedy:comply w/ code/keep clean the job site even when no construction activities were perform
Oct 20, 2018 · Penalty $625
Resolve - Class - 2
Chain link gates without windscreen at the time of my inspection of the site,i observed that all the chain link fence gates were missing therequired opague sturdy cloth "wide screens".provide the windscreens at
Jul 10, 2018
Resolve - Class - 1
Sec. 3301.2 failure to safeguard all persons. at the time of my inspection of the site,i observed the gate to the site was open & household debris are been dumped into the site. the condition of the site is not
Jul 10, 2018 · Penalty $625
Resolve - Class - 2
Job site fence not maintained pursuant to subsection at time of my in spection, answering above complaint i observed a large hole cut in jobsite fence having access to the lot and causing a hazard to public and
Jun 19, 2018
Resolve - Class - 1
Sec. 3307.1 jobsite fence. at time of inspection of proposed 9 sty new bldg. i observed that the job site fence was unstable & out of plumb & fence was coming apart at numerous areas. remedy: repair & replace
Apr 5, 2018
Resolve - Class - 2
Failure to safeguard all public & property affected by construction ope/rations. note: at the time of my inspection of a 9 sty bldg at grade level. i observed construction fence at exp#1,2&4 collapsing onto sid
Mar 19, 2018 · Penalty $10,000
Resolve - Class - 1
Bc3307.7.7 condition of fence. at the time of my inspection of a new 9 story building, site inactive. i observed the fence in place leaning towards the sidewalk and street at exposure one and four. failure to m
Dec 16, 2017 · Penalty $400
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Hotel (HR)
- Year built
- 2022
- Floors
- 9
- Residential units
- —
- Building area
- 160,279 ft²
- Lot area
- 42,166 ft²
- Zoning
- M1-2
- Community board
- 301
- Council district
- 34
- Block / lot
- 2994 / 75
- Assessed value
- $5,910,750
- Landmark / historic district
- No
Questions about 25 Stewart Avenue
Who owns 25 Stewart Avenue?
The owner of record in NYC Department of City Planning PLUTO data is 25c LLC.
Does 25 Stewart Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 25 Stewart Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 25 Stewart Avenue built?
City records list 2022 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.