99 Meserole Avenue
Brooklyn, NY 11222BBL 3-02596-0001Map
Owner of record: Ymca Of Greater N Y
99 Meserole Avenue is a public assembly built in 1906 in Brooklyn, 11222. The owner of record is Ymca Of Greater N Y. HPD has recorded 7 housing violations here, most recently on March 22, 2025.
- HPD violations
- 7
- DOB violations
- 13
- ECB violations
- 36
- HPD complaints
- 58
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 7
- ANon-hazardous
Post a proper notice of carbon monoxide detecting device requirements, in a form approved by the commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in a private dwelling.
Mar 22, 2025
Closed — Violation dismissed - ANon-hazardous
Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mail box [ missing notice ] at public hall, 2nd story
Mar 22, 2025
Closed — Violation dismissed - ANon-hazardous
Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building. at public hall, 2nd story
Mar 22, 2025
Closed — Violation dismissed - ANon-hazardous
§ 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor [ missing frame ] at public hall, 2nd story
Mar 22, 2025
Closed — Violation dismissed - ANon-hazardous
Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd.
Mar 22, 2025
Closed — Violation dismissed - ANon-hazardous
Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected
Mar 22, 2025
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 9, 2021
Closed — Violation dismissed
DOB building violations · 13
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 4, 2023
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 30, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 30, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 30, 2016
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2010 inspection report
Dec 13, 2011
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed
Show 3 more ↓
- Public assembly none
Pa-public assembly none
Nov 30, 1988
Dob violation - dismissed - Public assembly none
Pa-public assembly none
May 18, 1988
Dob violation - dismissed - Public assembly none
Pa-public assembly none
Dec 8, 1987
Dob violation - dismissed
ECB violations · 36
- Class - 1
Failure to maintain building in code compliant manner for vio# 39182462h. observed no fire stopping at penetration of waste line in 4th floor bathroom, along with shower that does not fully turn off., repair an
Sep 15, 2026 · Penalty $6,250
Active - Class - 2
Failure to comply with the commissioner's orders to file a certificate of correction with the dept of buildings for vio# 39182455j., file a certificate of correction
Sep 15, 2026 · Penalty $1,250
Active - Class - 2
Failure to comply with the commissioner's orders to file a certificate of correction with the dept of buildings for vio# 39182454h, file a certificate of correction
Sep 15, 2026 · Penalty $1,250
Active - Class - 2
Failure to comply with the commissioner's orders to file a certificate of correction with the dept of buildings for vio# 39182463j, file a certificate of correction
Sep 15, 2026 · Penalty $1,250
Active - Class - 2
Weil mclain boiler model # 1288. found rear coil leaking and front coil domestic relief valve leaking. correct violating conditions and submit a certificate of correction.
Mar 30, 2026 · Penalty $1,250
Active - Class - 1
Electrical closet not dedicated to electrical distribution equipment only. observed in the basement electrical closet a gas meter in the same rm as electrical panels / equipment. all electrical rms / closet sha
Mar 30, 2026 · Penalty $1,200
Active - Class - 1
Electrical work without a permit. observed thru out building the installation of exit signs also having exposed wires and no grounding to fixtures. no permit on file. potential fire / shock hazard.27-3018(b) al
Mar 30, 2026 · Penalty $1,250
Active - Class - 1
Observed throughout the building no trap wraps insulation under sinks. fourth floor bathroom wastes line penetration with no fire stop and shower doesn't shut off. second floor water fountain does not have a ve
Mar 30, 2026 · Penalty $2,500
Active - Class - 1
Observed in the cellar gas line not being supported properly and installed a waste line in dedicated electric room. bathroom door is striking the toilet which is contrary to code sections pc 102.3 ec 110.25, re
Mar 30, 2026 · Penalty $1,200
Active - Class - 2
I observed the disconnection of the branch circuit wiring supplying power to the previous sauna located in the rear of men's locker room at the time of my inspection, a permit issued in dob records was issued a
Mar 4, 2024 · Penalty $800
Resolve
Show 26 more ↓
- Class - 2
Observed in the gas meter room located at the sub cellar in the gas meter room no fresh air ventilation noted. as per 14.13.3 of the 1938 building code, the meter locations shall be clean, dry and free from ste
Feb 22, 2024 · Penalty $625
Resolve - Class - 2
Observed in the gas meter room as well as in the boiler room excessive combustible storage ( shelves for shoes, air conditioners, metal cabinet, boxes, ect). as per appendix in of the fuel gas code no storage s
Feb 22, 2024 · Penalty $625
Resolve - Class - 2
Observed gas leak on the boiler located in the basement/cellar. national grid tech confirmed the leak. as per 102.3 of the plumbing code maintenance. installations, both existing and new, and parts thereof shal
Feb 22, 2024 · Penalty $625
Resolve - Class - 2
At exposure # 1&2, several (+15 un) window a/a unit installed without support., repair and/or replace
May 18, 2022 · Penalty $312
Resolve - Class - 2
I observed in the bathrooms on the 4th ,2nd and 1st floor daycare defective gfci receptacles, mis-wired and/or broken., install gfc1 protection
May 18, 2022 · Penalty $1,200
Resolve - Class - 2
At cellar level, electrical room, ceiling damage due water penetration and at roof level, stair, walls show signs of water penetration, detachment of stucco and paint, also stairseveral cracks different locatio
May 18, 2022 · Penalty $625
Resolve - Class - 1
I observed in the electrical equipment room a flexible liquid-tite metallic conduit sealtite improperly terminated with exposed energized conductors, this is an immediate shock hazard. photos taken., comply wit
May 18, 2022 · Penalty $1,600
Resolve - Class - 2
At 4th fl, staircase b door , 3rd fl staircase a door and exit door near rm # 332, 2nd fl, staircase a door, do not close properly when inspected., repair/replace door
May 18, 2022 · Penalty $312
Resolve - Class - 2
Failure to maintain bldg in codecompliant manner.observed:@gas meter rm,excessive combustible material such as cardboard boxes,paints&other materials is being stored.repair &/or replace
Dec 14, 2021 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in codecompliant manner:observed:@exp1&2,window a/c units w/o bracket.(>10units).repair &/or replace.
Dec 14, 2021 · Penalty $625
Resolve - Class - 1
I observed in basement boiler room and meter room newly installed gas piping and fittings for boiler and no permit on file has any gas authorization given by the dob and boiler was on and working, file for requ
Mar 20, 2020 · Penalty $5,000
Resolve - Class - 1
I observed in basement boiler room flu piping for boiler with holes in the pipe allowing co to escape and into the air which is prohibited and not code complaint and is dangerous. nyc dob boiler division ceased
Mar 20, 2020 · Penalty $1,250
Resolve - Class - 1
I observed in basement boiler room and meter room newly installed gas piping for boiler and as per dob records the last inspection and test was performed on 08/23/2019 and failed due pressure test dropping and
Mar 20, 2020 · Penalty $2,500
Resolve - Class - 1
Holes is flue pipe, improper combustion of power flame burner. cease use issued.do not operate boiler untill all hazardous conditions are immediately corrected and dob is notified to lift cease use 2123932784
Mar 20, 2020
Resolve - Class - 2
Failure to comply w/ the commissioner's order contained in summon/vio# 35207850m issued on 9/9/16 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. for illegal gas droner coupling on house side of gas met
Aug 15, 2018 · Penalty $1,280
Resolve - Class - 2
Failure to maintain building in code-compliant manner. no fire stopping per bc 712.3; 27-345. note: holes in sub cellar walls, not fire stopped and laundry room. rem: provide/maintain fire stopping.
Feb 28, 2018 · Penalty $500
Resolve - Class - 1
Failure to install grounding electrode conductor in accordance with section. observed the following violating condition at water main pipe locate in the cellar. main grounding conductor installed on the wrong s
Feb 28, 2018 · Penalty $2,400
Resolve - Class - 2
Failure to maintain building in code-compliant manner.observed on 3/07/17 excessive storage in boiler room.(lockers,and a tall metal fan)no storage is to be kept in boiler room.
Mar 7, 2017 · Penalty $500
Resolve - Class - 1
Failure to provide a system of automatic sprinklers where req'd observed on 9/9/16 @ 11:30am at front entrance no sprinkler coverage. or alternate means. bc 903.2 & 27.954. remedy: provide a system of automatic
Sep 9, 2016
Resolve - Class - 1
Failure to maintain bldg in code complaint manner. observed on 9/9/16 @ 11:15am in bsmt-illegal gas fitting dresser (compliant) on house side of gas(stove) 3". remedy: repair/replace.
Sep 9, 2016 · Penalty $1,000
Resolve - Class - 2
Failure to have new or altered ply systems tested. observed on 9/9/16 at 11:15 in bst throughout new 5"nh drainage piping 2" and 4",pvc pip ing installed for sump pump.photos taken.rmdy:perform inspections.
Sep 9, 2016 · Penalty $500
Resolve - Class - 2
Exit door not self closing.noted:at first floor,adjacent to strength room the door opening to lorimer st not self close where has no closer.also at cellar,free weight room,the door opening to men's lockes room
May 19, 2016
Resolve - Class - 2
Failure to maintain building in code-compliant manner:no fire stopping per bc7123;27-345.noted:at cellar,boiler room,3 opening holes(each approx. 6"x6")in the ceiling exposing wood joists and sub flooring to st
May 19, 2016
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. insp dwg nov 3.11. premises under pc alt ii 320400419, loc 4.30.13. note, at time of inspection found; 1) plans indicate an
May 21, 2013 · Penalty $500
Resolve - Class - 2
Failure to maintain bldg in a code compliant manner. premises under pcalt ii 320400419, l.o.c. 4.30.13. note at time of inspection found: 1)noted 3 hr fpsc door @ base of stairs leading to oil tank rminoperable
May 21, 2013 · Penalty $250
Resolve - Non-hazardous
Altered building occupied without a valid certificate of occupancy required by open alteration application#1307/87 remedy:have above alt signed off and obtain a new certificate of occupancy from this dept or di
Oct 15, 1991 · Penalty $285
Resolve
Complaints
- Heat/hot water
Entire building
Feb 25, 2026 · Apt 314
Close - Heat/hot water
Entire building
Jan 21, 2026 · Apt 319
Close - Heat/hot water
Entire building
Nov 22, 2025 · Apt 339
Close - Heat/hot water
Entire building
Jul 5, 2025 · Apt 417
Close - Heat/hot water
Entire building
Mar 19, 2025 · Apt 3R
Close - Heat/hot water
Entire building
Oct 10, 2023 · Apt 433
Close - Heat/hot water
Entire building
Oct 9, 2023 · Apt BLDG
Close - Heat/hot water
Entire building
Apr 9, 2018 · Apt 422
Close - Nonconst
Vermin
Nov 21, 2012 · Apt 309
Close - Paint/plaster
Wall
Nov 14, 2012 · Apt 440
Close
Show 40 more ↓
- General
Doors
Nov 14, 2012 · Apt 440
Close - Nonconst
Vermin
Nov 14, 2012 · Apt 440
Close - Nonconst
Vermin
Nov 14, 2012 · Apt 440
Close - Heating
Heat related
Apr 28, 2012 · Apt 5
Close - Nonconst
Vermin
Aug 20, 2010 · Apt 4
Close - General
Windows
Aug 20, 2010 · Apt 4
Close - Nonconst
Vermin
Jun 7, 2010 · Apt RM406
Close - Nonconst
Vermin
Jun 7, 2010 · Apt RM406
Close - Nonconst
Vermin
Jun 7, 2010 · Apt RM406
Close - Nonconst
Vermin
Jun 7, 2010 · Apt RM406
Close - Nonconst
Rubbish
May 25, 2010 · Apt 406
Close - Nonconst
Rubbish
May 25, 2010 · Apt 406
Close - Nonconst
Vermin
May 25, 2010 · Apt 406
Close - General
Windows
May 25, 2010 · Apt 406
Close - Nonconst
Vermin
May 25, 2010 · Apt 406
Close - Nonconst
Vermin
May 5, 2010 · Apt RM406
Close - General
Locks
May 5, 2010 · Apt RM406
Close - General
Doors
May 5, 2010 · Apt RM406
Close - General
Doors
May 5, 2010 · Apt RM406
Close - General
Doors
May 5, 2010 · Apt RM406
Close - General
Windows
May 5, 2010 · Apt RM406
Close - Nonconst
Vermin
May 5, 2010 · Apt RM406
Close - Nonconst
Smoke detector
May 5, 2010 · Apt RM406
Close - Plumbing
Shower-stall
May 5, 2010 · Apt RM406
Close - General
Windows
May 5, 2010 · Apt RM406
Close - Nonconst
Vermin
Apr 19, 2010 · Apt 406
Close - Nonconst
Vermin
Apr 19, 2010 · Apt 406
Close - General
Floor
Apr 19, 2010 · Apt 406
Close - General
Windows
Apr 19, 2010 · Apt 406
Close - General
Windows
Apr 19, 2010 · Apt 406
Close - General
Doors
Apr 19, 2010 · Apt 406
Close - General
Doors
Apr 19, 2010 · Apt 406
Close - Heating
Heat related
Apr 19, 2010 · Apt 406
Close - Nonconst
Vermin
Apr 13, 2010 · Apt 210
Close - General
Doors
Apr 6, 2010 · Apt RM406
Close - Nonconst
Vermin
Apr 6, 2010 · Apt RM406
Close - Nonconst
Vermin
Apr 6, 2010 · Apt RM406
Close - Nonconst
Vermin
Apr 6, 2010 · Apt RM406
Close - Plumbing
Water supply
Apr 6, 2010 · Apt RM406
Close - General
Floor
Mar 15, 2010 · Apt RM406
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Public assembly (P3)
- Year built
- 1906
- Floors
- 4
- Residential units
- —
- Building area
- 40,000 ft²
- Lot area
- 10,000 ft²
- Zoning
- C4-3A
- Community board
- 301
- Council district
- 33
- Block / lot
- 2596 / 1
- Assessed value
- $2,408,850
- Landmark / historic district
- No
HPD registration #347240, last renewed Nov 18, 2025.
Questions about 99 Meserole Avenue
Who owns 99 Meserole Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Ymca Of Greater N Y.
Does 99 Meserole Avenue have violations?
Yes. NYC HPD has recorded 7 housing violations at this property.
Is 99 Meserole Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 99 Meserole Avenue built?
City records list 1906 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.