230 Kent Avenue
Brooklyn, NY 11249BBL 3-02362-0001Map
Owner of record: Kent Riverview LLC
230 Kent Avenue is a vacant lot in Brooklyn, 11249. The owner of record is Kent Riverview LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 17
- ECB violations
- 23
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 17
- Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - active - Construction other optional
C-construction other optional
Jun 11, 2018
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2015 inspection report
Feb 24, 2017
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2014 inspection report
Oct 1, 2015
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2013 inspection report
Mar 3, 2015
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2012 inspection report
May 15, 2014
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2011 inspection report
Mar 1, 2013
Dob violation - active
Show 7 more ↓
- Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 29, 1995
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 16, 1993
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 1, 1993
Dob violation - dismissed
ECB violations · 23
- Class - 1
Bc3307.2 observed unsafe work and storage zone. observe material stores adj to the sidewalk at exp# 3 with no fencing/barriers to fully enclosing materials, giving public unauthorized or unlimited access to ma
Aug 16, 2026 · Penalty $5,000
Resolve - Class - 2
Observed jersey barriers at exp#2 3 not as per manufacture specs jersey barriers not continuously interlocked (missing connector pins) not fill with water/sand several barriers damage which poses a potential ha
Aug 16, 2026 · Penalty $1,250
Resolve - Class - 2
Work w/o a permit. at time of inspection,observed 8 feet high fence inplace at exp#1,2&3(chain link fence). upon review the dept records,(bis & dob now)observed that there were no permits issued for chainlink
Jan 25, 2022 · Penalty $3,125
Resolve - Class - 2
Job site fence not constructed pursuant to subsection.at time of inspection i observed at excavation.stage enclosed with chain link fence contrary to permit and not as per code.fence shall be at least 8 feet hi
Jan 8, 2020
Resolve - Class - 1
Failure to notify the dept of an accident or incident that resulted ina fatality or injury. note 1 worker was on his knees when a stone rolled over on his back worker was taken by ambulance to the hospital. as
Dec 16, 2019
Resolve - Class - 1
Permit holder failed to ensure workers receive site-specific safety orientations. note: at the time of my inspection of a excavation site responding to a incident. upon my inspection i asked the competent perso
Oct 8, 2019
Resolve - Class - 2
Design. note: at the time of inspection of a alteration earth work site. i observed construction fence in place attached to barriers. when asked for design drawings for fence none were provided. remedy: provide
Oct 8, 2019
Resolve - Class - 1
Failure to institue & maintain safety equipment measures & temporary construction. note: at the time of my inspection responding to a incident inspection reveals the worker that was injured was taking a measure
Oct 8, 2019
Resolve - Class - 1
Failure to maintain record of pre-shift safety meeting for each worker. note: at the time of inspection responding to a incident i observed earthwork site,when asked the competent person at the site for the pre
Oct 8, 2019
Resolve - Class - 1
Work w/o a permit. note: at the time of inspection of a alteration site doing earthwork i observed 3 water filter tanks for contaminated water on site w/no permit to have tank on site required a permit.
Oct 8, 2019
Resolve
Show 13 more ↓
- Class - 1
Unsafe storage of materials during construction or demolition,combustible material & equipment. note: at the time of inspection i observed unsafe storage of flammable material,observed cabinet that contains fla
Oct 8, 2019
Resolve - Class - 1
Failure to promptly notify the dept. note: at the time of my inspection responding to compliant where a worker get hit on his back w/rolling stone,compained of back pain & side pain taken to hospital. inspectio
Oct 8, 2019 · Penalty $5,000
Resolve - Class - 1
Construction superintendent failed to immediately notify the dept of condition as required. note: at the time of my inspection responding tocompliant where a worker got hit on his back w/rolling stone complaine
Oct 8, 2019
Resolve - Class - 2
Jobsite fence not maintained pursuant to subsection 1 sty bldg demoed & filled to grade. at the time of my inspection i observed the jobsites fence was leaning & was flimsy when i pushed on it at minimum force
Jul 23, 2019
Resolve - Class - 2
Temporary construction equipment on site expired permit fence. 1 sty bldg demoed site filled to grade. at the time of my inspection i observed jobsite was filled to grade & a boom lift & garbage container was
Jul 23, 2019
Resolve - Class - 2
Job site fence not constructed or maintained pursuant to subsection. at time of inspection i observed proposed full demolition of 1 story building currently at the street level w/ no ongoing work activity prese
May 15, 2019
Resolve - Class - 1
Failure to safeguard all persons and property affected by constructionoperations. at time of inspection i observed full demolition of a 1 story building currently at the street level. job is locked w/ no work a
May 15, 2019 · Penalty $400
Resolve - Class - 1
Prohibited outdoor advertising company sign on sidewalk shed or construction fence. at time of inspection i observed proposed full demolition of 1 story building currently at the street level w/ no ongoing work
May 15, 2019 · Penalty $1,250
Resolve - Class - 2
Failure to safeguard. observed approx 40ft 4inch pvc drain pipe free standing. base is attached to a 3-4ft brick wall w/no tieback or bracing anywhere else pipe is at perimeter edge of exp#3 & blowing in the
Mar 16, 2019
Resolve - Class - 2
Sec. 3307.6 failure to maintain pedentrain protection. at time of inspection of full demo site observed sidewalk shed @ exp#1&2. exposed wiring in path of pedestrian walkway located @ exp#1. hanging & unbraced
Mar 16, 2019
Resolve - Class - 2
Job site fence not pursuant to subsection. at time of inspection of demo site inactive observed no viewing panels at all along perimeter of site. no viewable areas into site from public way. multiple area have
Mar 16, 2019
Resolve - Class - 2
Pedestrian protection does not meet code specifications. at time of inspection i observed sidewalk shed & construction fence in place. observed that there was less than 5ft passageway for pedestrians to walk
Feb 27, 2019 · Penalty $2,400
Resolve - Class - 2
Pedestrian protection does not meet code specifications. at time of inspection i observed sidewalk shed in place. observed the upright posts were less than 18 inches from the street curb. not code compliant#330
Feb 27, 2019 · Penalty $625
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Vacant lot (V1)
- Year built
- —
- Floors
- —
- Residential units
- —
- Building area
- —
- Lot area
- 5,862 ft²
- Zoning
- M1-4/R7X
- Community board
- 301
- Council district
- 33
- Block / lot
- 2362 / 1
- Assessed value
- $397,800
- Landmark / historic district
- No
Questions about 230 Kent Avenue
Who owns 230 Kent Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Kent Riverview LLC.
Does 230 Kent Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 230 Kent Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.