roofy

1215 Fulton Street

Brooklyn, NY 11216BBL 3-01842-0015Map

Owner of record: Fulton Property Owner LLC

1215 Fulton Street is an elevator apartment building built in 2023 in Brooklyn, 11216. It has 240 residential units across 10 floors. The owner of record is Fulton Property Owner LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
9
ECB violations
49
HPD complaints
2

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 9

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Apr 17, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - dismissed
  • Construction other optional

    Partial collapse of load bearing masonry wall@exp#2,(exp#4 of 1213 fulton st),w.potential of further collapse.movement of soe system un- known remedy:comply w.code,imediatly strt opticl monitorng of soe systm.take readngs 1x/day.provid plan&acessmnt of data.plumbness.survey of 1213

    Jul 20, 2023

    Dob violation - dismissed
  • Construction other optional

    Failure 2 maintain & safeguard adj bldg during construction.operations inspectn of 1221 fulton st.reveals cracking cellar slab,sheetrock & collapsed staircase. remedy: comply w code,retain rdp to perform enginerng evaluation of damaged structure. submit by 7/10/2023 stablty assesmt...w resolution paths

    Jun 30, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 14, 2020

    Dob violation - dismissed
  • Construction other optional

    Structure rendered non compliant. due to disrepair of adjacent building at 1213 fulton the vacant lot shall be vacated

    Feb 7, 2020

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Jan 11, 2017

    Vp*-violation unserved ecb- dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 11, 2017

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Apr 8, 1990

    Dob violation - dismissed

ECB violations · 49

  • Class - 2

    At time of inspection, i observed the owner of the new building failed to extend the chimney of the adjacent property at exposure #2 as per code section bc 2113.1.6.1./ extend chimney.

    Jul 11, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    During my inspection at an active job site of th10-story nb, i observed that the guardrails are not constructed in accordance with code requirements. there are missing cable clamps, loose nettings, and 0 cables

    Mar 10, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    During my inspection at an active job site of a 10-story new building (nb), i observed that housekeeping was inadequate. mixed materials and debris were present, creating a trip and fall hazard for workers and

    Mar 10, 2025 · Penalty $1,250

    Resolve
  • Class - 1

    Bc 3314.4.8_during my inspection of an active jobsite for a 10-story new building (nb), i observed the supported scaffold at exp #1(halsey str.). the scaffold had loose planks, missing safety pins and cross bra

    Mar 10, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    During my inspection at the active job site of a 10-story new building (site safety job), i observed numerous areas with unsafe extension cables and exposed wires. this condition poses a significant risk of ele

    Mar 10, 2025 · Penalty $2,000

    Resolve
  • Class - 2

    Bc 3303.7.2: during my inspection of an active job site for a 10-story new building (nb), i observed inadequate fire extinguishers. specifically, there were missing safety pins, old or damaged units, and exting

    Mar 10, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping per section requirements. at the time of inspection, i observed excessive amount of debris in multiple rooms, hallways, and on the roofs. debris consist of metal studs,

    Jan 30, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    Obsvd susp scafds at exps#3&4 (all in use) built contrary to dob-aprvd plans: suspnsn lines attached to shackle around bolt going through beam in lieu of bolted stirrup as shown, no mech stops at beam front as

    Jul 8, 2024 · Penalty $620

    Resolve
  • Class - 2

    Observed proposed 10 str nb with 3 suspended scaffolds in use at exp# 3 (middle section, fulton st-facing) and 1 suspended scaffold in use at exp# 4. upon review of the provided dob-approved site safety plan, i

    Jul 8, 2024 · Penalty $620

    Resolve
  • Class - 1

    Inspection reveals that electric pallet jack being use to move material was not completely turn off,wheels were not block to prevent movement or remove pallet jack from pallet as per manufacturer specifications

    May 9, 2024 · Penalty $2,500

    Resolve
Show 39 more ↓
  • Class - 1

    3301.2 responding an incident, where worker get caught in between fan and pallet, inspection revealed: gc failure to institute and maintain safety measures, inadequate communication between workers, work contra

    May 9, 2024

    Resolve
  • Class - 1

    At the time of inspection on an active job site currently at roof level, i observed at exposure 1 on all floors throughout building construction materials, gang box with tools stored within 10 feet of leading

    Apr 1, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to provide means and method by pe for concrete repairs. as noted: at time of inspection at an active jobsite for a proposed 10 storybuilding concrete cast-in-place already at the 10th floor level. obser

    Dec 21, 2023

    Resolve
  • Class - 1

    Rcny 101-06. bc1704.1.1.2. the respondent failed to perform duties as a special inspection agency(rcny;bc1704.1.1.2) in that respondent failed to immediately notify the dob in writing of the hazardous condition

    Oct 20, 2023

    Resolve
  • Class - 1

    During construction observed wall&roof had collapsed at 1213 fulton st. monitoring note 7a on soe-501 had requirement "vibrations: continuously from start of soe installation to completion of ground floor slab

    Jul 20, 2023 · Penalty $10,000

    Resolve
  • Class - 1

    Inspection of 1215 fulton street of a full wall and roof collapse of adjacent property 1213 fulton street. no vibration monitoring were installed prior to the start of construction operations. failure to safegu

    Jul 20, 2023

    Resolve
  • Class - 1

    At the time of inspection, internal engineer report dated june 5. 2023 regarding to collapsed cellar stair of exp4 adjoining property was provided. upon research, no notification was filed to dob. permit holder

    Jun 28, 2023

    Resolve
  • Class - 2

    Failure to notify the department of an accident or damage to adjoining property. internal engineer report on june,5, 2023 regarding collapsed cellar stair for adjacent property at exp#4 was provided, upon resea

    Jun 28, 2023

    Resolve
  • Class - 2

    At the time of inspection, observed multiple cracks in exp4 adj building's (1221 fulton) cellar, 2nd and 3rd floor dwelling units. i observed cracked cellar slab along the foundation wall in parallel direct to

    Jun 28, 2023

    Resolve
  • Class - 2

    At time of inspection observed construction fence in disrepair conditions, panels leaning outward and inward at multiple locations along halsey street property's backyard and arlington place backyards., comply

    Jul 12, 2022 · Penalty $5,000

    Resolve
  • Class - 2

    Failure to comply w/ the commissioner's order contained in summons/vio#39036637p issued on 2/23/21 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01. remedy:comply w/ commissioner's

    Apr 14, 2021 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to maintain building in code-compliant manner. upon inspection, observed, fence at exposure #1 of vacant lot, is partially loose, collapsed and fell down on the sidewalk, which could cause pedestrians t

    Feb 23, 2021 · Penalty $3,125

    Resolve
  • Class - 1

    Failure to maintain construction fence and safeguard all public and property note:upon completely inspection 1230 bedford ave and returning to city car parked at the corner of halsey street and bedford ave i ob

    Jan 29, 2021 · Penalty $5,000

    Resolve
  • Class - 1

    At time of inspection, construction fence at exposure 3 of lot at halsey street is partially collapsed - fence is open, allowing public access to lot, which is vacated under full vacate order #b57/20 issued 02-

    Jul 22, 2020 · Penalty $500

    Resolve
  • Class - 2

    At time of inspection, construction fence at premises is built without a permit, obtain all permits; obtain fence permit

    Jul 22, 2020

    Resolve
  • Class - 2

    Temporary construction equipment on site. expired permit. observed: construction fence installed on vacant lot has no renewed permit for construction fence. the fence was construction by expired permit #3212812

    Apr 4, 2018 · Penalty $1,250

    Resolve
  • Class - 2

    Pedestrian protection does not meet code specification. note: observed sidewalk shed lights are not operating at time of inspection 4:20am that does not meet code specification 3307.6.4.8. remedy: comply w/code

    Dec 1, 2016 · Penalty $2,400

    Resolve
  • Class - 1

    Sec. 3313.1 combustible liquid not stored properly. noticed at time of inspection noticed approx 40 gallons of (kerosine) stored inside shanty not properly as per code. remedy: store combustible liquids properl

    Oct 13, 2016 · Penalty $1,600

    Resolve
  • Class - 1

    Sec. 3301.1.2 no fdny permit for kerosine on site noticed approx 40 gal of kerosine on site. remedy: stop all work & remove kerosine or obtain permit.

    Oct 13, 2016 · Penalty $1,600

    Resolve
  • Class - 1

    Sec. 3307.3 no overhead protection. noticed at time of inspection demolition in progress. noticed at exp#1,2,3 overhead protection not provided as required. workers on site doing demo & clean up work.

    Oct 13, 2016

    Resolve
  • Class - 1

    Failure to carry out demolition as required in safe manner. noticed attime of inspection demolition of 2 sty comm bldg in place noticed workers demo 2nd fl ceiling & roof in large section approx 10feet,2nd floo

    Oct 13, 2016 · Penalty $2,400

    Resolve
  • Class - 1

    Failure to maintain bldg in code-compliant manner. noted: metal awningover sidewalk defective. some panels under the awning missing, some loosed in danger to collapse/falling. remedy: make all necessary repairs

    Mar 3, 2014 · Penalty $500

    Resolve
  • Class - 2

    Sidewalk shed does not meet building code specifications.noted:at timeof inspection sidewalk shed on exposure#1 was missing parapets on all 3 sides,platform was loose and in danger of falling.rmdy:conform to

    May 20, 2013 · Penalty $5,000

    Resolve
  • Class - 2

    Temp construction equipment on site - expired permit. noted:at time ofinspection sidewalk shed on site at exposure #1 with expired permit job#310019226 expiration date 12/31/07.rmdy:conformto building code,ob

    May 20, 2013 · Penalty $2,000

    Resolve
  • Class - 2

    Failure to comply with the commissioner's order to file a cert of correction with the dob for notice of violation #34925165y issued on 2-5-12 pursuant to 28-204.4 & 1rcny 102-01 for failure to maintain. rem:fil

    Apr 16, 2012 · Penalty $4,000

    Resolve
  • Class - 2

    Sdwlk shed does not meet code specifications.note:sections of parapet missing on shed thruout.no vandal proof fixtures on shed.inadequate signage on shed.rem:conform shed to code specifications

    Apr 19, 2010 · Penalty $10,000

    Resolve
  • Class - 2

    Sdwlk shed does not meet code specifications.noted:sdwlk shed missing approx 18ft of parapet,musd sills under post not making contact, (broken) post not plumb & leaning.rem:conform shed to code specifications

    Dec 30, 2009 · Penalty $10,000

    Resolve
  • Class - 1

    Failure to maintain bldg in a code-compliant manner defect noted: at 1st sty, theater, ceiling thruout plaster is broken, loose, unkeyed & fallen to floor, due to water damage. floor thruout theater has debris

    Dec 30, 2008 · Penalty $5,000

    Resolve
  • Hazardous

    Failure to maintain exterior bldg! haz defects noted: 1. broken & defective canopy above entry to bldg & sidewalk. in between ionic columns w/dislodgement of west parapet enclosure, missing metal sections

    Aug 17, 2007 · Penalty $2,500

    Resolve
  • Hazardous

    Failure to maintain exterior bldg wall. noted: marquee at the front ofthe bldg is in dire disrepair w/the following problems. bolted connections & steel members are rusted. missing steel members causing

    Aug 15, 2007 · Penalty $2,500

    Resolve
  • Hazardous

    Failure to maintain bldg exterior noted:1st floor marquee(old theatre)sheet metal at the underside is rotted & pulling away,several of 2' x 2' sections of sheet metal are hanging off.remedy:make area safe,

    Jul 4, 2007 · Penalty $2,500

    Resolve
  • Hazardous

    Failure to maintain exterior bldg wall. defect noted:80' masonry fenceat the south east of above premises is in a state of collapse or has collapsed. approx 45' of the 6' high masonry wall has collapsed into

    May 7, 2007 · Penalty $2,500

    Resolve
  • Non-hazardous

    Work without a permit, work noted at 2nd fl. partitions erected of sheetrock a wood. creating 6 rms, also raised platform. approx 3 ft high and 30ft x 20 ft. remedy: obtain a permit.

    Jun 25, 2003 · Penalty $2,500

    Resolve
  • Non-hazardous

    Exit passage/corridor. decreased by obstructions, 2nd floor rear exit leadingto groove level has vehicles parked obstructing 2nd means of egress to street. remedy: remove obstruction.

    Jun 25, 2003 · Penalty $2,500

    Resolve
  • Non-hazardous

    Occupancy contrary to that allowed by the certificate of occupancy co fo #64953 lists 1st fl as theatre,2nd fl as office's presently 2nd fl converted to a church with seating for approx 300 people remedy:discon

    Jun 25, 2003 · Penalty $2,500

    Resolve
  • Non-hazardous

    Operation of a place of assembly without a public assembly permit, at 2nd fl arranged as a church with seating present for approx 300 people. remedy: obtain a pa permit.

    Jun 25, 2003 · Penalty $2,500

    Resolve
  • Non-hazardous

    Occupancy contrary to that allowed by the c of o #64953131. offices at 2nd story change and now arranged to be occupied as a place of assembly dancing hall and entertainment.remedy:discontinue illegal occupancy

    May 1, 2000 · Penalty $2,500

    Resolve
  • Non-hazardous

    Operation of place of assembly w/o a current permit.second story arranged to be occupied as entertainment and dancing hall.remedy:disonctinue illegal use forthwith.

    May 1, 2000 · Penalty $2,500

    Resolve
  • Hazardous

    Failure to maintain.defect is missing and defective tread at rear fire escape remedy:make all repairs at rear fire escape to the satisfaction of this dept.(2)loose and defective ceiling at front marquee over si

    May 1, 2000 · Penalty $5,000

    Resolve

Complaints

  • Plumbing

    Radiator

    Oct 6, 2026 · Apt 401

    Close
  • Unsanitary condition

    Pests

    Sep 13, 2026 · Apt 323

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D7)
Year built
2023
Floors
10
Residential units
240
Building area
219,385 ft²
Lot area
42,700 ft²
Zoning
C4-5D
Community board
303
Council district
36
Block / lot
1842 / 15
Assessed value
$21,030,300
Landmark / historic district
No

HPD registration #391777, last renewed Dec 23, 2025.

Questions about 1215 Fulton Street

Who owns 1215 Fulton Street?

The owner of record in NYC Department of City Planning PLUTO data is Fulton Property Owner LLC.

Does 1215 Fulton Street have violations?

NYC HPD has no housing violations on record for this property.

Is 1215 Fulton Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 1215 Fulton Street built?

City records list 2023 as the year it was built.

How many apartments are in 1215 Fulton Street?

It has 240 residential units and 241 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.