554 Willoughby Avenue
Brooklyn, NY 11206BBL 3-01767-0027Map
Owner of record: Willo Castle LLC
554 Willoughby Avenue is a two-family home built in 1910 in Brooklyn, 11206. It has 2 residential units across 3 floors. The owner of record is Willo Castle LLC. HPD has recorded 15 housing violations here, most recently on March 28, 2018. 8 of the 15 most recent violations are still open.
- HPD violations
- 15
- DOB violations
- 14
- ECB violations
- 18
- HPD complaints
- 44
What to know
Immediately hazardous issues among recent violations are still open.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 15
- BHazardous
Replace with new the broken or defective exterior glass pane at lower sash window , 1st from east at south , 1st story
Mar 28, 2018
Closed — Violation closed - CImmediately hazardous
Provide an adequate supply of heat for the apartment in the entire apartment located at apt 3rdfl, 3rd story, 1st apartment from north at east
Dec 13, 2017 · Apt 3RDFL
Open — Nov sent out - BHazardous
Repair the broken or defective plastered surfaces and paint in uniform color at ceiling in the 2nd room from north located at apt 3, 3rd story, 1st apartment from north at east
Nov 28, 2017 · Apt 3
Open — Nov sent out - BHazardous
Repair the broken or defective plastered surfaces and paint in uniform color at ceiling in the 1st room from north located at apt 3, 3rd story, 1st apartment from north at east
Nov 28, 2017 · Apt 3
Open — Nov sent out - BHazardous
Repair the roof so that it will not leak over ceiling in the 2nd room from north located at apt 3, 3rd story, 1st apartment from north at east
Nov 28, 2017 · Apt 3
Open — Nov sent out - BHazardous
Repair the broken or defective plastered surfaces and paint in uniform color at ceiling in the 1st room from north located at apt 3, 3rd story, 1st apartment from north at east
Nov 28, 2017 · Apt 3
Open — Nov sent out - BHazardous
Repair the roof so that it will not leak over ceiling in the kitchen located at apt 3, 3rd story, 1st apartment from north at east
Nov 28, 2017 · Apt 3
Open — Nov sent out - CImmediately hazardous
Properly secure the loose bannister at public hall stairs, 1st story
Nov 28, 2017
Closed — Violation closed - CImmediately hazardous
Replace with new the missing balusters(total of 8) at public hall stairs, 1st story
Nov 28, 2017
Closed — Violation closed - CImmediately hazardous
Repair the broken or defective plastered surfaces and paint in uniform color ceiling in the 2nd room from north located at apt 3flr, 3rd story, 1st apartment from north at east
Nov 15, 2017 · Apt 3FLR
Closed — Violation closed
Show 5 more ↓
- BHazardous
Repair the roof so that it will not leak at ceiling in the 2nd room from north located at apt 3flr, 3rd story, 1st apartment from north at east
Nov 15, 2017 · Apt 3FLR
Open — Nov sent out - CImmediately hazardous
Replace with new the missing balusters (6) at public hall stairs, 1st story
Nov 15, 2017
Closed — Violation closed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Oct 20, 2017
Open — Info nov sent out - CImmediately hazardous
Provide a safe and adequate supply of electric service to the fixtures .. in the entire apartment located at apt 2fl, 2nd story, 1st apartment from north at east
Oct 18, 2017 · Apt 2FL
Closed — Violation closed - CImmediately hazardous
Remove the illegal fastening double cylinder key operated lock at security gate at entrance to building , 1st story
Oct 4, 2017
Closed — Violation closed
DOB building violations · 14
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 27, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 1, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 1, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 1, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 1, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 1, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 23, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 23, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 23, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 23, 2021
Dob violation - dismissed
Show 4 more ↓
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 23, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 23, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed
ECB violations · 18
- Class - 1
Unlawfully continued work while on notice of a stop work order.at time of inspection of 3 story topped off building under permit #340743770 observed review of bix jobsite put under partial stop work order on 2/
Apr 1, 2022 · Penalty $5,000
Resolve - Class - 2
Failure to maintain adequate housekeeping.at time of inspection of 3 story topped off building under permit #340743770 observed inadequate housekeeping on 1st floor & rear yard exp #3.entire 1st floor & rear ya
Apr 1, 2022
Resolve - Class - 2
Expired permit(fence) at the time of my sinepction of a 3 story building i observed construction fence in place did a search in bis which alerted me that the fence permit has being expired from 02-13-2021
Jul 30, 2021 · Penalty $1,250
Resolve - Class - 1
3314.4.4.4-supported pipe scaffold(netting) noted at the time of my isnepction of a 3 story building i observed supported pipe scaffold at exp #1 with ebris netting loose and hanging failure to maintain
Jul 30, 2021 · Penalty $625
Resolve - Class - 1
Failure to maintain safety equipment measure or temp const-no guardrails note:ato my insp of 3stybldg w/active const work in bsmt level.i observed@exp4 open approx7' drop to bsmt level.worker travel by open&tha
Jun 2, 2021 · Penalty $12,500
Resolve - Class - 1
Unlawfully contd work while on notice of swo note:ato my insp of 3stybldg w/active work in progress@bsmt level.i observed 2work demo&removing plywood from exp4.upon rev dept record here allow to only clean&secu
Jun 2, 2021 · Penalty $2,500
Resolve - Class - 1
Bc3301.1.2 comply w/fire code note:ato my insp of 3stybldg w/active const work in progress@bsmt level.i observed 2workers removing&demo plywood when insp reqeust for worker to exit bsmt,2workers had to maintain
Jun 2, 2021 · Penalty $625
Resolve - Class - 1
Failure to designate &/or have const super present@site as required note:ato my insp of 3stybldg w/actual const work in progress i observed @bsmt level2 work demo plywood while there&3other removing debris from
Jun 2, 2021 · Penalty $2,500
Resolve - Class - 1
Bc3314.4.4.5 maintain support scf netting note:ato my insp of 3stybldgw/const work in progress,i observed@exp1 support scf w/netting system in place.upon rev support scf there are open <1" thruout scf failure t
Jun 2, 2021 · Penalty $625
Resolve - Class - 1
Bc3307.7 missing jobsite fence.at the time of inspection on an active jobsite i observed missing construction fence at exp.#3 & at exp.#2,4 rear.job site is accessible to public.this condition puts public in da
Mar 22, 2021 · Penalty $2,500
Resolve
Show 8 more ↓
- Class - 1
Failure to designate an dor have a construction superintendnet present at site as required at the time of my inspection on an active jobsite i observed new foundation and 3 story horizontal enlargement of the b
Mar 22, 2021
Resolve - Class - 1
Bc3301.2 failure to provide overhead protection for adjacent property.at the time of inspection of a 3 story alt2 jobsite,active work.workerperforming exterior work on a 3rd story level.i observed that no overh
Mar 22, 2021 · Penalty $2,500
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temporary construction-no guardrail system.at the time of inspection on an activejobsite i observed missing guardrail system throughout job site on all
Mar 22, 2021 · Penalty $5,000
Resolve - Class - 1
Work w/out a permit.at the time of inspection i observed horizontal enlargement of the bldg at exp.#3 w/out permit.also observed new foundation & structual works throughout bldg w/out proper permits.active perm
Mar 22, 2021
Resolve - Class - 1
Bc3314.1 supported pipe scaffold installed not as per code.at the timeof inspection on an active jobsite i observed supported pipe scaffold installed at exp.#1 & exp#3 not as per code & in use by workers.(1)mis
Mar 22, 2021 · Penalty $2,500
Resolve - Class - 1
Failure to safeg uard all persons affected by construction @time of inspection upon arrival @site i observed the door to access into the bldg of the fence was opened in the sidewalk & upon entering the permitte
May 28, 2020
Resolve - Class - 1
Failure to maintain adequate housekeeping per section requirement uponentering the permitted site through unsecured & open door files of construction rubbish mostly consist of lumber that were not stared in non
May 28, 2020 · Penalty $2,500
Resolve - Class - 2
Failure of permit holder to provide inspection access to & expose workon active & permitted work site. at time of inspection of a 3 sty bldg i observed approx 5 workers on site at bldg front exp#1 refused acces
May 21, 2020 · Penalty $2,500
Resolve
Complaints
- Water leak
Heavy flow
Mar 3, 2018 · Apt 3RDFL
Close - Water leak
Heavy flow
Mar 3, 2018 · Apt 3RDFL
Close - Paint/plaster
Ceiling
Mar 3, 2018 · Apt 3RDFL
Close - Heat/hot water
Apartment only
Mar 3, 2018 · Apt 3RDFL
Close - Heat/hot water
Apartment only
Dec 13, 2017 · Apt 3RDFL
Close - Heat/hot water
Apartment only
Dec 12, 2017 · Apt 2NDFL
Close - Heat/hot water
Entire building
Dec 11, 2017 · Apt 3FL
Close - Heat/hot water
Apartment only
Dec 10, 2017 · Apt 2
Close - Electric
No lighting
Nov 14, 2017 · Apt 3RDFL
Close - Heat/hot water
Entire building
Nov 14, 2017 · Apt 3FLR
Close
Show 34 more ↓
- Heat/hot water
Entire building
Nov 13, 2017 · Apt 3FL
Close - Heat/hot water
Entire building
Nov 12, 2017 · Apt 3FL
Close - Heat/hot water
Apartment only
Nov 11, 2017 · Apt 3
Close - Heat/hot water
Entire building
Nov 10, 2017 · Apt 3
Close - Water leak
Heavy flow
Nov 9, 2017 · Apt 3
Close - Water leak
Slow leak
Nov 9, 2017 · Apt 3
Close - Paint/plaster
Ceiling
Nov 9, 2017 · Apt 3
Close - Heat/hot water
Entire building
Nov 9, 2017 · Apt 3
Close - Heat/hot water
Entire building
Nov 8, 2017 · Apt 3FLOO
Close - Heat/hot water
Entire building
Nov 7, 2017 · Apt 3
Close - Heat/hot water
Entire building
Nov 1, 2017 · Apt 3
Close - Electric
No lighting
Oct 11, 2017 · Apt 2FLR
Close - Electric
Power outage
Oct 3, 2017 · Apt 2FL
Close - Heating
Heat related
Oct 24, 2005 · Apt 2
Close - Plumbing
Bathtub/shower
Oct 24, 2005 · Apt 2
Close - General
Fire-escape
Oct 24, 2005 · Apt 2
Close - Nonconst
Vermin
Oct 24, 2005 · Apt 2
Close - Paint/plaster
Ceiling
Oct 24, 2005 · Apt 2
Close - Electric
Wiring
Oct 24, 2005 · Apt 2
Close - Plumbing
Water-leaks
Oct 24, 2005 · Apt 2
Close - Plumbing
Water-leaks
Oct 5, 2005 · Apt 2
Close - Plumbing
Bathtub/shower
Sep 21, 2005 · Apt 2
Close - Paint/plaster
Ceiling
Sep 21, 2005 · Apt 2
Close - Paint/plaster
Ceiling
Sep 21, 2005 · Apt 2
Close - Paint/plaster
Ceiling
Sep 21, 2005 · Apt 2
Close - Plumbing
Water-leaks
Sep 21, 2005 · Apt 2
Close - General
Doors
Aug 29, 2005 · Apt 2
Close - Electric
Wiring
Aug 29, 2005 · Apt 2
Close - Nonconst
Vermin
Aug 29, 2005 · Apt 2
Close - Paint/plaster
Wall
Aug 29, 2005 · Apt 2
Close - General
Windows
Aug 29, 2005 · Apt 2
Close - Plumbing
Water-leaks
Aug 29, 2005 · Apt 2
Close - Paint/plaster
Ceiling
Sep 25, 2003 · Apt 2
Close - General
Doors
Sep 25, 2003 · Apt 2
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Two-family home (B2)
- Year built
- 1910
- Floors
- 3
- Residential units
- 2
- Building area
- 3,489 ft²
- Lot area
- 2,000 ft²
- Zoning
- R6B
- Community board
- 303
- Council district
- 36
- Block / lot
- 1767 / 27
- Assessed value
- $126,120
- Landmark / historic district
- No
Questions about 554 Willoughby Avenue
Who owns 554 Willoughby Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Willo Castle LLC.
Does 554 Willoughby Avenue have violations?
Yes. NYC HPD has recorded 15 housing violations at this property.
Is 554 Willoughby Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 554 Willoughby Avenue built?
City records list 1910 as the year it was built.
How many apartments are in 554 Willoughby Avenue?
It has 2 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.