roofy

463 Pulaski Street

Brooklyn, NY 11221BBL 3-01596-0052Map

Owner of record: Noke Properties LLC

463 Pulaski Street is an office building built in 2019 in Brooklyn, 11221. The owner of record is Noke Properties LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
2
ECB violations
26
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 2

  • Construction other optional

    Borugh commissioner has ordered all work stopped under appl# 321490604(nb) due to contract withdrawal/stop all work immediately and make site safe

    Oct 15, 2020

    Dob violation - dismissed
  • Construction other optional

    Borough commissioner has ordered all work stopped under applicatio #321490604(nb) due to contractor withdrawal/stop all work immediately and make site safe

    Oct 15, 2020

    Dob violation - dismissed

ECB violations · 26

  • Class - 1

    Construction superintendent failed to perform duties per code. note: at the time of my inspection of an 6 sty w/consist at the time of my inspection of an 6 sty w/consist of masonry & facade work. i observed

    Nov 19, 2020 · Penalty $10,000

    Resolve
  • Class - 1

    Sec. 3301.13.12 competent person. note: at the time of my inspection of an 6 sty level construction work in progress upon request for competent person to verify compliance w/code none was perovided or available

    Nov 19, 2020 · Penalty $625

    Resolve
  • Class - 1

    Failure to ensure worker attend pre-shift safety meeting. note: at thetime of my inspection of a 6 sty new bldg job site w/2 workers doing facade work at exp#2. upon request for pre-shift meeting before commenc

    Nov 19, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Sec. 3309. access agreement. note: at the time of my inspection of a 6sty near bldg job site w/2 workers doing facade work at exp#2. responded to complain that installing supported scaffold at adjacent property

    Nov 19, 2020 · Penalty $625

    Resolve
  • Class - 1

    Permit holder failed to ensuure workers receive site safety orientation. note: at the time of my inspecton of a 6 sty new bldg job site w/2 workers soing facade work at exp#2. upon request for site safety orien

    Nov 19, 2020 · Penalty $5,000

    Resolve
  • Class - 2

    Jobsite fence not constructed or maintained pursuant to subsection. @ time of inspection of a proposed 6 sty new bldg under construction,i observed a jobsite/construction fence at exp#1 w/the following conditio

    Mar 25, 2020

    Resolve
  • Class - 2

    Temporary construction equipment on site-exp permit. at time of inspection of a proposed 6 sty new bldg under construction,i observed a sidewalk shed at exp#1. upon review of the dept records,i found that the

    Mar 25, 2020 · Penalty $625

    Resolve
  • Class - 1

    Sec. 3307.6 sidewalk shed not constructed or maintained in code-compliance. at time of inspection of a proposed 6 sty new bldg under construction,i observed a sidewalk shed at exp#1 w/the following conditions:

    Mar 25, 2020 · Penalty $625

    Resolve
  • Class - 1

    Work without a permit-scaffold over 40ft.at time of inspection of a 6 story new building under construction i was provided access by worker and observed supported scaffold installed at exp3 approx 50ft in heigh

    Feb 18, 2020 · Penalty $5,000

    Resolve
  • Class - 2

    Bc330910-roof protection not installed as per code.at the time of inspection of inspection of a 6 story building under construction to the roof level i observed roof protection does not extend 20ft as per code

    Feb 18, 2020 · Penalty $625

    Resolve
Show 16 more ↓
  • Class - 1

    Missing guardrails.at the time of inspeciton of a 6 story new buildingunder construction i was given access by worker on site and observed missing and inadequate guardrails in several locations.at the six floor

    Feb 18, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Missing handrails.at the time of inspection of a 6 story under construction up to the roof level i was given access toy worker who informed me he was checking the fire alarm and observed no handrails installed

    Feb 18, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to designte and have construction superintendent present at site when required.at time of inspection of an 6 story new building jobsite.i observed no construction superintendent at jobsite workers were

    Dec 4, 2019 · Penalty $12,500

    Resolve
  • Class - 1

    Construction superintendent failed to perform duties as per rule.at time of inspection of an active 6 story new building jobsite i observed 2-3 workers working with no supervision worker stated superintendent h

    Dec 4, 2019 · Penalty $12,500

    Resolve
  • Class - 1

    Failure to designate competent person.at time of inspection of an active 6 story new building jobsite i observed no competent person or construction superintendent at jobsite worker were working with no supervi

    Dec 4, 2019 · Penalty $12,500

    Resolve
  • Class - 2

    Sidewalk shed/pedestrian protection does not meet code specifictions..at time of inspection of a 6 story nb currently at 5 story i observed sidewalk shed at exp#1 with vertical members out of plum and leaning c

    Nov 25, 2019 · Penalty $2,400

    Resolve
  • Class - 1

    Bc33016-design drawing.at time of inspection,i observed at 2nd fl and 3rd fl elevator pit a temp platform with temp staircase.upon request for design drawing for the platform and staircase none was provided.lac

    Sep 20, 2019 · Penalty $625

    Resolve
  • Class - 1

    Guardrail missing/inadequate.at time of inspeciton i observed at 3rd fl being erected.walking up to that level i observed no guardrail around the staircase to protect people from danger of fall.at the 3rd floor

    Sep 20, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Bc170411-special inspection/tr1 statement of responsibility not filed.at time of inspection i observed cold form steel erected around the building,floor joist and framing.upon renew of the bis system i found th

    Sep 20, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Bc330113-manufactor specification.at time of inspection,i observed cold form steel work in place andupon request for manufactor specs for cfs work in place none was provided to me on site.lack of manufacturer s

    Sep 20, 2019 · Penalty $625

    Resolve
  • Class - 1

    Failure to designate &/or have a competent person &/or construction superintendent on site as required. at the time of my inspection on an active jobsite of a proposed 6 sty bldg. i observed workers on site as

    Jul 26, 2019

    Resolve
  • Class - 1

    Sec. 3301.6 temporary platform-no design drawings. at the time of my inspection on an active jobsite of a proposed 6 sty bldg. i observed on site located on top of the staircase leading into the cellar a tempor

    Jul 26, 2019 · Penalty $625

    Resolve
  • Class - 1

    Failure to maintain adequate housekeeping per section requirements. atthe time of my inspection on an active jobsite of a proposed 6 sty bldg. it was observed that throughout the 1st fl of the site housekeeping

    Jul 26, 2019 · Penalty $625

    Resolve
  • Class - 1

    Unsafe storage of materials during construction or demolition. at the time of my inspection on an active jobsite of a proposed 6 sty bldg. iobserved on the 1st fl level & the rear of exp#3 material was not stor

    Jul 26, 2019

    Resolve
  • Class - 1

    Failure to notify dob within 24-48 hours of the start of excavation.observed at time of inspection contractor has excavated for nb foundation walls & earthwork notification was provided.rem:contractor failed to

    May 21, 2019

    Resolve
  • Class - 2

    Bc 3307.7inadequate fence.i observed at time of inspection no viewing panel.rem:inadequate fence.

    May 21, 2019

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Office building (O5)
Year built
2019
Floors
6
Residential units
—
Building area
5,017 ft²
Lot area
1,264 ft²
Zoning
C4-4L
Community board
303
Council district
36
Block / lot
1596 / 52
Assessed value
$495,000
Landmark / historic district
No

Questions about 463 Pulaski Street

Who owns 463 Pulaski Street?

The owner of record in NYC Department of City Planning PLUTO data is Noke Properties LLC.

Does 463 Pulaski Street have violations?

NYC HPD has no housing violations on record for this property.

Is 463 Pulaski Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 463 Pulaski Street built?

City records list 2019 as the year it was built.