roofy

340 Chauncey Street

Brooklyn, NY 11233BBL 3-01514-7502Map

Owner of record: Kingsland Chauncey LLC

340 Chauncey Street is a condominium built in 2018 in Brooklyn, 11233. It has 13 residential units across 4 floors. The owner of record is Kingsland Chauncey LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
0
ECB violations
39
HPD complaints
10

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 0

No DOB violations on record

ECB violations · 39

  • Class - 1

    Sec. 3301.2 failure to provide overhead protection where required. at the time of my inspection,i observed a new bldg w/an unfinished coping(not installed-roof level)of exp#1&3 in addition to nothing that there

    Mar 13, 2020 · Penalty $625

    Resolve
  • Class - 2

    Sec. 3303.7.2 fire extinguishers shall be provided in accordance w/thenyc fire code. at the time of my inspection i observed several portable fire extinguishing units not inspected,not mounted,damaged,inoperabl

    Mar 13, 2020 · Penalty $620

    Resolve
  • Class - 1

    Sec. 3301.2 failure to provide overhead protection where required at the time of my inspection i observed an(nb)project w/an unfinished coping(not installed)at exp#1&3 in addition to observing that there was no

    Mar 13, 2020 · Penalty $625

    Resolve
  • Class - 2

    Sec. 3303.7.2 fire extinguishers shall be provided in accordance w/thenyc fire code. at the time of my inspection & walk through i obersevedseveral portsble fire extinguishers. not inspected,not inspected not

    Mar 13, 2020 · Penalty $620

    Resolve
  • Class - 1

    Sec. 3301.13.12 competent person. note: at the time of my inspection of a 4 sty bldg w/work in progress,i requested to speak to the competent person,i was told that he was not onsite & went to get material. the

    Dec 11, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Sec. 3301.13.12 competent person. note: at the time of my inspection of a 4 sty bldg w/work in progress,i requested to speak to the competent person,i was told that he was not onsite & he went to get material.

    Dec 11, 2019

    Resolve
  • Class - 1

    No superintendent. note: at the time of my inspection of a 4 sty bldg w/work in progress,i requested to speak w/the superintendent,i was told that he was not onsite. no superintendent on the jobsite & no logboo

    Dec 11, 2019

    Resolve
  • Class - 2

    Sec. 3303.4 housekeeping. note: at the time of my inspection of a 4 sty bldg w/work in progress,i observed that there was inadequate housekeeping at exp#3 & at basement 3rd fl level & the stairway. failure to

    Dec 11, 2019 · Penalty $625

    Resolve
  • Class - 1

    Superintendent failed to perform duties. note: at the time of my inspection of a 4 sty bldg w/work in progress. i observed 1)the construction fence at exp#1 was leaning & out of plumb hovering into the walkway

    Dec 11, 2019

    Resolve
  • Class - 2

    Sec. 3303.4 housekeeping. note: at the time of my inspection of a 4 sty bldg w/work in progress i observed that there was inadequate housekeeping at exp#3. failure to provide & maintain housekeeping created a

    Dec 11, 2019 · Penalty $625

    Resolve
Show 29 more ↓
  • Class - 1

    Superintendent failed to perform duties. note: at the time of my inspection of a 4 sty bldg w/work in progress,i observed 1)the constructionfence at exp#1 was leaning & out of plumb hovering into the walkway.

    Dec 11, 2019 · Penalty $10,000

    Resolve
  • Class - 1

    Sec. 3307.7.7 condition of fence. note: at the time of my inspection of a 4 sty bldg w/work in progress,i observed that the construction fence was not plumb,but it was leaning towards the pedestrian walkway/sid

    Dec 11, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    No superintendent. note: at the time of my inspection of a 4 sty bldg w/work in progress,i requested to speak w/a superintendent who was tapping the walls,he said that he was not onsite. no superintendent on th

    Dec 11, 2019

    Resolve
  • Class - 1

    Sec. 3307.7.7 condition of fence. note: at the time of my inspection of a 4 sty bldg w/work in progress,i observed that the construction fence was not plumb. it was leaning towards the pedestrian walkway/sidewa

    Dec 11, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Unlawfully continued to work while on notice of swo.noted:at time of inspection work was completed above 4th floor staircase while on noticeof s.w.o of april 19,2019.rem;comply with stop wrok order.

    Oct 3, 2019

    Resolve
  • Class - 1

    Unlawfully continued to work while on the notice of stop work order.noted:at time of inspection work was completed above 4th floor staircasewhile on notice of s.w.o of april,18 2019.rem:comply with stop work or

    Oct 3, 2019

    Resolve
  • Class - 1

    Sec. 3314.5 platform construction(no design drawings). at the time of my inspection on an active jobsite of a 4 sty bldg. i observed on the 4th fl staircase a platform was built out of plywood,2x8 lumber & a 6f

    Apr 18, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Manufacturer specs/equipment use contrary to specs/miuse of equipment.at the time of my inspection on an active jobsite of a 4 sty bldg. i observed a worker(contractor)on the 4th fl staircase using a hand held

    Apr 18, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to maintain adequate housekeeping per section required. at thetime of my inspection on an active jobsite of a 4 sty bldg. i observedat ecxp#3 rear yard permit holder failed to maintain adequate housekee

    Apr 18, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to have or maintain the daily required log(inadequate log book)at the time of my inspection on an active jobsite of a 4 sty bldg. i requested to see the daily log book from the competent person on the

    Apr 18, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to maintain adequate housekeeping per section required. at thetime of my inspection on an active jobsite of a 4 sty bldg. i observed at exp#3 rear yard permit holder failed to maintain adequate housekee

    Apr 18, 2019 · Penalty $1,250

    Resolve
  • Class - 2

    Sec. 3307.6.5 sidewalk shed maintaince,debris,storage,sharp edges. at the time of my inspection on an active job site of a 4 sty bldg. i observed the sws at exp#1 was not maintained by permit holder as per code

    Apr 18, 2019 · Penalty $625

    Resolve
  • Class - 1

    Sec. 3303.2.3.1 temporary lighting on jobsite. at the time of my inspection on an active jobsite of a 4 sty bldg. i observed the permit holder failed to maintain adequate lighting on the site throughout the bld

    Apr 18, 2019 · Penalty $625

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction-no guardrails. at the time of my inspection on an active jobsite of a 4 sty bldg. i observed openings in various locations permi

    Apr 18, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Sec. 3303.2.3.1 temporary lighting on job site. at the time of my inspection on an active jobsite of a 4 sty bldg. i observed the permit holder failed to maintain adequate lighting on the site throughout the

    Apr 18, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction-no guardrails. at the time of my inspection on an active jobsite of a 4 sty bldg. i observed openings in various locations permi

    Apr 18, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Sec. 3314.5 platform construction(no desig drawings). at the time of my inspection on an active jobsite of a 4 sty bldg. i observed on the 4th fl staircase a platform was built out of plywood 2x8 lumber & a 6ft

    Apr 18, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to have or maintain the required daily log(inadequate log book). at the time of my inspection on an active job site of a 4 sty bldg.i requested to see the daily log book from the competent person on the

    Apr 18, 2019 · Penalty $1,250

    Resolve
  • Class - 2

    Sec. 3307.6.5 sidewalk shed maintenance,debris,storage,sharp edges. atthe time of my inspection on an active jobsite of a 4 sty nbldg. i observed the sws at exp#1 was not maintained by permit holder as per code

    Apr 18, 2019 · Penalty $2,400

    Resolve
  • Class - 2

    During an energy code compliance inspection at a new building with permit number 321194006, i observed that all installed windows have a u-factor of 0.29 which is contrary to u-factors of 0.25 and 0.27 required

    Mar 22, 2019 · Penalty $5,000

    Resolve
  • Class - 2

    During an energy code compliance inspection at job site with permit number 321193882, i observed that the u-factor on installed windows was 0.29 and this is contrary to requirements on approved plans as shown o

    Mar 22, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Sec. 3309.14 failure to protect or adequately protect adjoining properties during construction or demolition operations-no roof protection. at time of inspection i observed cmu block wall at exp#2 greater than

    Oct 24, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    Work does not conform to approved construction documents &/or approvedamendments. at time of inspection i observed steel beams on cmu walls at exp#2 & party wall w/o support as per plans shown on plans. cmu to

    Oct 24, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    Sec. 2113.9 failure to extended chimney at least 3ft above roof level.i observed at time of inspection contractor failed to extend chimney 3ft above roof level as per nyc bc code exp#2. remedy: comply w/code.

    Oct 24, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    Work does not conform to approved construction documents &/or approvedamendment. at time of inspection,i observed steel beams seating on cmu wall w/o lateral support as per approved plans. plans shows cmu to be

    Oct 24, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by construction operation--no overhead protection.at time of inspection of a 4 story steel framed building under construction at 2nd floor level,active job

    Aug 14, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    3301.1.2.-failure to provide werder fdny certification for welong operation.at time of inspection of a 4 story new building new steel framed building with framing operations at 3rd floor level,cutting operative

    Aug 14, 2018 · Penalty $625

    Resolve
  • Class - 1

    3301.6.1-no design drawing provided for q decking provided for make shift platform.at time of inspection of a 4 story steel framed building under construction at 2nd floor level.active job site.i observed that

    Aug 14, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    3313.1.no fdny permit for oxygon/acetylene use and storage on job site.at time of inspection of a 4 story steel framed building under construction at 2nd floor level.active job site,i observed a worker with cut

    Aug 14, 2018 · Penalty $2,500

    Resolve

Complaints

  • Plumbing

    Water supply

    Jun 20, 2016 · Apt 1STFL

    Close
  • Appliance

    Electric/gas range

    Jun 20, 2016 · Apt 1STFL

    Close
  • Plumbing

    Water supply

    Aug 6, 2015 · Apt 1STFL

    Close
  • General

    Cooking gas

    Aug 6, 2015 · Apt 1STFL

    Close
  • Unsanitary condition

    Garbage/recycling storage

    Apr 10, 2015 · Apt BLDG

    Close
  • Unsanitary condition

    Garbage/recycling storage

    Apr 10, 2015 · Apt BLDG

    Close
  • Unsanitary condition

    Garbage/recycling storage

    Apr 10, 2015 · Apt BLDG

    Close
  • Heat/hot water

    Apartment only

    Feb 20, 2015 · Apt 1STFL

    Close
  • Heat/hot water

    Apartment only

    Jan 7, 2015 · Apt 1FL

    Close
  • Heating

    Heat related

    Feb 24, 2013 · Apt 1A

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Condominium (R2)
Year built
2018
Floors
4
Residential units
13
Building area
10,075 ft²
Lot area
4,500 ft²
Zoning
R6B
Community board
303
Council district
41
Block / lot
1514 / 7502
Assessed value
$949,503
Landmark / historic district
No

HPD registration #390418, last renewed Sep 6, 2025.

Questions about 340 Chauncey Street

Who owns 340 Chauncey Street?

The owner of record in NYC Department of City Planning PLUTO data is Kingsland Chauncey LLC.

Does 340 Chauncey Street have violations?

NYC HPD has no housing violations on record for this property.

Is 340 Chauncey Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 340 Chauncey Street built?

City records list 2018 as the year it was built.

How many apartments are in 340 Chauncey Street?

It has 13 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.