2317 Pacific Street
Brooklyn, NY 11233BBL 3-01435-0051Map
Owner of record: Alhalemi, Khalil Abdo
2317 Pacific Street is a walk-up apartment building built in 2016 in Brooklyn, 11233. It has 3 residential units across 3 floors. The owner of record is Alhalemi, Khalil Abdo. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 2
- ECB violations
- 15
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 2
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 11, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 11, 2019
Dob violation - dismissed
ECB violations · 15
- Class - 1
Sec. 3303.4.1.1 failure to maintain sidewalk exp#1. at time of inspection on a 3 sty new bldg observed broken & unleveled adphalt/gravel at exp#1 of property creating an unsage trip & fall hazard for the public
Sep 19, 2019 · Penalty $2,500
Resolve - Class - 2
Jobsite fence not constructed/maintained pursuant to subsection viewing panels.at time of inspection on a 3 story new building observed missing plexi glass for jobsite viewing panels on the fence.rem:provide pl
Sep 19, 2019 · Penalty $400
Resolve - Class - 1
Sec. 3307.7.7 condition of fences. at time of inspection on a 3 sty new bldg observed jobsite fence at exp#1 not adequate maintained. observed the following unsafe conditions 1)jobsite panels not adequately sec
Sep 19, 2019 · Penalty $2,500
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments.nb job#321110542 on an energy compliance inspection i observed all exterior walls(exposures #1,2,3 and 4)woe installed i obser
Jan 27, 2017 · Penalty $500
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments.nb job#321110537 on an energy compliance inspection i observed the amount of permanently installed light fixtures are over 250
Jan 27, 2017 · Penalty $500
Resolve - Class - 2
Work does not conform to approved documents and/or approved amendmentsnb-job#321110542 on an energy compliance inspection i observed.the amounts of permanently installed light fixtures are over 250% in excess o
Jan 27, 2017 · Penalty $500
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments.nb-job#321110532 on an energy compliance inspection i observed all exterior wall(exposure #1,2,3 and 4)were installed contrary
Jan 27, 2017 · Penalty $500
Resolve - Class - 2
Sec: bc3304.7. failure to provide adequate means of exit from excavation. @ time of insp it was observed that the way no adequate egress from the excavated area. rem: provide ladder dirt ramp,etc.
May 19, 2016
Resolve - Class - 2
Failure to provide approved/ accepted plans @ job site @ time of insp. @ time of insp it was observed that there was no support of excavation plans on site. rem: provide plans.
May 19, 2016
Resolve - Class - 1
Sec: bc3301.3. designated construction superintendent (semi-controlledinspector) has not adequately discharged his responsibilties in that construction work has not been found to be in compliance w/ approved co
May 19, 2016 · Penalty $1,600
Resolve
Show 5 more ↓
- Class - 1
Failure to provide protection @ side of excavation. @ time of insp it was observed that excavation operation was around 10ft deep w/out no shoring, angle of repose or 45 degree to protect the soil from collapsi
May 19, 2016 · Penalty $2,400
Resolve - Class - 2
Sec: bc3304.4.4. failure to provide 3ft 6inch guard rail or solid enclosure around open & accessible sides of excavation. @ time of insp there was no guard rail arounf the excavation area @ exp#3 & 4. rem: comp
May 19, 2016
Resolve - Class - 1
Sec: bc3309.6. failure to monitor adjoining structures for movement in all directions during excavation- related activity that may adversely affect adjoining structures. @ time of insp there was no monitoring o
May 19, 2016 · Penalty $1,600
Resolve - Class - 1
Sec: failure to adequately support adjoining ground &/or structure affected by excavation. @ time of insp there was no adequate shoring @ exp#4 to adequately support the adjoining ground of adjoining bldg. rem:
May 19, 2016 · Penalty $1,600
Resolve - Class - 2
Work does not conform to approved documents &/or approved amendments. @ time of insp it was observed that the shoring was not install acordding to plans. the plan indicates that wood shoring to be install when
May 19, 2016
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Walk-up apartment building (C0)
- Year built
- 2016
- Floors
- 3
- Residential units
- 3
- Building area
- 3,417 ft²
- Lot area
- 2,116 ft²
- Zoning
- R6
- Community board
- 316
- Council district
- 37
- Block / lot
- 1435 / 51
- Assessed value
- $79,380
- Landmark / historic district
- No
Questions about 2317 Pacific Street
Who owns 2317 Pacific Street?
The owner of record in NYC Department of City Planning PLUTO data is Alhalemi, Khalil Abdo.
Does 2317 Pacific Street have violations?
NYC HPD has no housing violations on record for this property.
Is 2317 Pacific Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 2317 Pacific Street built?
City records list 2016 as the year it was built.
How many apartments are in 2317 Pacific Street?
It has 3 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.