roofy

135 32 Street

Brooklyn, NY 11232BBL 3-00676-0053Map

Owner of record: 32 Street Liu LLC

135 32 Street is a hotel built in 2016 in Brooklyn, 11232. The owner of record is 32 Street Liu LLC. HPD has recorded 11 housing violations here, most recently on May 11, 2026. 6 of the 11 most recent violations are still open.

HPD violations
11
DOB violations
28
ECB violations
19
HPD complaints
1

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation May 11, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 11

  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    May 11, 2026

    Open — Nov sent out
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 20, 2025

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Jun 16, 2025

    Open — Nov sent out
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 29, 2024

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 18, 2024

    Open — Nov sent out
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 22, 2023

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 31, 2023

    Open — Nov sent out
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 14, 2022

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 10, 2022

    Open — Nov sent out
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Mar 10, 2022

    Closed — Violation dismissed
Show 1 more ↓
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 20, 2021

    Open — Nov sent out

DOB building violations · 28

  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Dec 1, 2021

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2020

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2020

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Feb 2, 2020

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 19, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 19, 2019

    Dob violation - resolved
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Nov 2, 2019

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2019

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2019

    Dob violation - dismissed
  • Plumbing none

    The dob has issued a notice to revoke job #340292711 due to revocation of fire suppression contractors license. all work in connection with this application has been ordered to stop except to make site safe

    Dec 17, 2017

    Dob violation - dismissed
Show 18 more ↓
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 8, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 8, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 8, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 8, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 8, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 8, 2017

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 7, 2000

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 10, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 29, 1995

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jul 25, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 1, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 16, 1993

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 1, 1993

    Dob violation - dismissed

ECB violations · 19

  • Class - 2

    Jobsite fence not contructed or maintained pursuant to subsection. at time of inspection observed a construction with 6 story building was pn progress, during inspection. noted: at exposure #1 fence outside the

    Apr 20, 2018

    Resolve
  • Class - 1

    Failure to ha e or and designate construction superintedent present atsite when required. at the time of my inspection it was observed an active construction site with new building and otuside on teh expo#1 rep

    Mar 29, 2018 · Penalty $625

    Resolve
  • Class - 2

    Sec. 3301-02(d) construction superintendent fails to maintain &/or make job site logs available. at the mtime of my inspection it was observed an active construction site w/new bldg erected & work going inside

    Mar 29, 2018

    Resolve
  • Class - 1

    Construction superintendent failed to perform duties as per rule. at the mtime of my inspection it was observed new bldg already erected w/finishing work going on inside & outside bldg where it was noted that

    Mar 29, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    Sec. 3308.3 vertical netting not to code. noticed at time of inspection nb in progress noticed on 6th fl vertical netting no to code. noticed nets have holes & are not secured & missing. remedy: stop all work

    Dec 15, 2016 · Penalty $400

    Resolve
  • Class - 2

    No handrails. noticed at time of inspection on 2st floor staircase. noticed no handrails provided. rmdy: provide handrails as per code.

    Dec 15, 2016 · Penalty $400

    Resolve
  • Class - 1

    Bc3303.4.1 maintenance sidewalk not maintained free of tripping hazards noticed at time of inspection pedestrian sidewalk at exp1 not main tained free of tripping hazards.sidewalk cracked,sunk down, uneven, ha

    Dec 15, 2016 · Penalty $400

    Resolve
  • Class - 1

    Sec. 3301.7 no design. noticed at time of inspection nb in progress. noticed on 6th fl stairway platform erected w/scaffold on top no design drawing on site for platform. remedy: stop all use of platform & prov

    Dec 15, 2016 · Penalty $400

    Resolve
  • Class - 2

    Bc3303.3 obstruction of sidewalk w/o dot permit. noticed sidewalk hasfence and sws erected on site dot permit posted at site expired 7-2016rmdy: obtain new dot permit.

    Dec 15, 2016 · Penalty $400

    Resolve
  • Class - 2

    Sidewalk shed nto to code. noticed at time of inspection sws erected at exp1 not to code noticed cross braces removed and hanging off. rmdy:conform shed to code.

    Dec 15, 2016 · Penalty $2,400

    Resolve
Show 9 more ↓
  • Class - 1

    Failure to maintain housekeeping, noticed at time of inspection nb in progress noticed housekeeping throughout entire site housekeeping not maintained to code debris piles all over entire floors blocking egress

    Dec 15, 2016 · Penalty $400

    Resolve
  • Class - 1

    Sec. 3314.9.2 no base plates for scaffold. noticed at time of inspection nb in progress noticed several sections of scaffold erected on 6th fl had no base plates. remedy: stop all use of scaffold & provide base

    Dec 15, 2016 · Penalty $1,600

    Resolve
  • Class - 1

    Bc3307.6.3 sidewalk shed not covering are to be protected. noticed at time of inspection nb in progress.noticed at exp1 sws erected on sidewalk not covering the full length. noticed sidewalk shed is install

    Dec 15, 2016 · Penalty $400

    Resolve
  • Class - 1

    No guardrails. noticed at time of inspection nb in progress noticed on3rd & 5th flrs no guardrails provided on edge of bldg inside window openings. remedy: stop all work on 3rd & 5th fl provide guardrails.

    Dec 15, 2016 · Penalty $1,200

    Resolve
  • Class - 2

    Bc3309.11 inadequate tree protection. noticed at time of inspection at exp1 tree partially unprotected. noticed protection in place is collapsed. rmdy: protect tree to code.

    Dec 15, 2016 · Penalty $400

    Resolve
  • Class - 1

    Failure to adequately supervise work at a construction site.so as to maintain a safe construction site and ensure compliance with chapter 33the following hazardous conditions were observed and faso issued. sw5

    Dec 15, 2016 · Penalty $1,600

    Resolve
  • Class - 2

    Work does not confrom to approved plans or construction documents. noted: approved plans on site job #320595940 3/5/16 approved plans do not show a construction fence detail or method of construction.

    Feb 29, 2016 · Penalty $250

    Resolve
  • Class - 2

    Dept of transportation permit not posted for sidewalk street closing. noted: 8'high wood construciton fence installed under app#320941077 & closing 5 1/2ft sidewalk w/no dot permit posted on premises.

    Mar 18, 2015

    Resolve
  • Class - 2

    Defective job site fence. noted: 8'high wood construciton fence installed under app#320941077 approx 120ft x 120ft w/8ft wide wood panel along rear exposure collapsed. site is vacant & graded. remedy: repair

    Mar 18, 2015

    Resolve

Complaints

  • Plumbing

    Toilet

    Dec 25, 2020 · Apt 604A

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Hotel (H3)
Year built
2016
Floors
6
Residential units
—
Building area
25,738 ft²
Lot area
10,518 ft²
Zoning
M1-2D
Community board
307
Council district
38
Block / lot
676 / 53
Assessed value
$3,456,900
Landmark / historic district
No

Questions about 135 32 Street

Who owns 135 32 Street?

The owner of record in NYC Department of City Planning PLUTO data is 32 Street Liu LLC.

Does 135 32 Street have violations?

Yes. NYC HPD has recorded 11 housing violations at this property.

Is 135 32 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 135 32 Street built?

City records list 2016 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.