561 President Street
Brooklyn, NY 11215BBL 3-00441-0042Map
Owner of record: President Sai II , LLC
561 President Street is a hotel built in 2018 in Brooklyn, 11215. The owner of record is President Sai II , LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 16
- ECB violations
- 40
- HPD complaints
- 1
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 16
- Construction other optional
Partial vacate order. haz conditions were obsvd at wall directly adj parking lot in rear of hotel. wall is in state of disrepair, several cracks & spalling masonry. wall is at risk of copllapsing onto parking lot harming any people or property in the lot. vacate only the entire parking lot in rear of bldg(union st)until conditions are remedied
Sep 22, 2026
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 2, 2023
Dob violation - dismissed - Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Dec 1, 2022
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 2, 2022
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 in 2021
Aug 21, 2022
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2022
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 16, 2020
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2020
Dob violation - dismissed - Construction other optional
The dob hereby orders you to stop all work under job #320915943 due to contractor withdrawal
May 8, 2020
Dob violation - dismissed - Construction other optional
The dob hereby orders you to stop all work under job #320915943 due to contractor withdrawal
May 8, 2020
Dob violation - dismissed
Show 6 more ↓
- Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 31, 2017
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Feb 27, 2009
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 21, 2008
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Apr 2, 2007
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 8, 2001
Dob violation - dismissed
ECB violations · 40
- Class - 3
Violation of the zoning resolution .at time of inspection i observed at front expo.1 a gray vehicle with license plate #lvx 7635 parked has been parked on sidewalk ,which blocked the traffic for pedestrians .;
Aug 6, 2026
Resolve - Class - 2
Failure to maintain adequate housekeeping per section requirements. note: at time of inspection of 5 sty new bldg under finishes activities,i observed construction materials & debris are stored on front of the
Jun 9, 2021
Resolve - Class - 2
Bc3307.21 obstruction of streets or sidewak.note:at time of inspection of 5 story new building observed jobsite is closing the sidewalk by a yellow tab where there is a bobcat occupying the sidewalk at exp #1
Jun 9, 2021
Resolve - Class - 2
Provision of law:3314.failure to maintain supported scaffold on site as per code.at time of inspection on an active 5 story nb construction site notice supported scaffold at all expos not maintaned as per code
Jun 25, 2020 · Penalty $620
Resolve - Class - 1
Work does not conform to approved const documents and/or approve amendments. @time of inspection on an active 5 sty nb const site, notice ofexp 2&4 needle beams that were not conforming with approve plans,(1)
Jun 25, 2020 · Penalty $2,500
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments.at time of inspection active job site interior work on progress.upon request drawing for supported scaffold observed work cont
Mar 19, 2020 · Penalty $3,125
Resolve - Class - 2
Jobsite fence not constructed or maintained pursuant to subsection.at the time of inspection it was observed that the jobsite fence had no plexi glass on the view part.this creates a hazard for people walking t
Dec 14, 2019 · Penalty $1,000
Resolve - Class - 1
Unlawfully continued work while under notice of stop work order. at time of posting service for vio#35449400r i found an active jobsite. significant work had continued to take place at parapet. workers found wo
Sep 26, 2019 · Penalty $12,500
Resolve - Class - 1
Unlawfully continued work while on notice of stop work order. at time of inspection,site under partial swo including explict instruction no work within "10' of leading edge at all perimeter". i observed laborer
Sep 24, 2019 · Penalty $5,000
Resolve - Class - 1
Standing water 3' or more note at time of my inspection of a 5th story building under construction at 5th story stage i observed large waterover 3inces depth thru-out basement.stop all work in basement area exc
Sep 20, 2019 · Penalty $2,500
Resolve
Show 30 more ↓
- Class - 2
Floor and exit signs missing note:at time of my inspection of a 5 story building under construction at 5th story level construction work in progress i observed there were floor or exit signs posted at stairways
Sep 20, 2019
Resolve - Class - 1
Guard rails missing note at time of my insepction of a5 story buildingunder construction at 5 story stage construction at 5 story stage construction work in progress.i observed open access to elevator shaft ent
Sep 20, 2019 · Penalty $5,000
Resolve - Class - 1
3308.5 netting. note:at time of my inspection of a 5 story building under construction at 5 story level construction work in progress. i observed that there was no netting at an unenclosed perimeter between the
Sep 20, 2019 · Penalty $6,250
Resolve - Class - 1
Bc3307.4/work and storage zone.note:at time of my inspection of a story bldg.at 5th floor level construction work in progress i observed 5thfloor level construction work in progress i observed large quantity of
Sep 20, 2019 · Penalty $2,500
Resolve - Class - 1
Design drawing.note:at time of my inspection of a 5th story bldg,underconstruction at 5th story leel bldg,under construction at 5th story level construction work in progress.i observed platforms built in elevat
Sep 20, 2019 · Penalty $6,250
Resolve - Class - 1
Housekeeping.note:at time of my inspection of a 5th story building under construction at 5th story level i observed excessive construction debris and materials thru-lut jobsite from 1st story to 5th story creat
Sep 20, 2019 · Penalty $2,500
Resolve - Class - 2
Failure to maintain adequate housekeeping at the time of my inspection 5 sty nb up to roof level work in progress observed to adequate houseepinga t 1,2,& 3 floor const materials and debris create dtripped haza
Sep 4, 2019
Resolve - Class - 2
3307.6:failure to mainatin sws(sidewalk shed) at the time of my inspection 5 sty nb up to roof level work in progress observed sws at expos 1 not mainted as per code sws parapet detached or bracing loose and di
Sep 4, 2019
Resolve - Class - 1
Sec.3301.2 failure to institute safety measures. at time of inspectionof an active 5 sty work site observed no guardrail system in place @ roof level w/active steel work being perform. cable were not in place &
Apr 15, 2019 · Penalty $2,500
Resolve - Class - 1
Sec. 3301.2 safety measures. at time of inspection of an active 5 sty work site currently @ roof level observed 2pcs of structural steel approx 20 foot long by 18'wide resting on top of steel columns. when lock
Apr 15, 2019 · Penalty $2,500
Resolve - Class - 1
Sec. 3309.10 protection of adj roofs. at time of inspection of an active 5 sty site w/structural steel work being done approx 30 feet of adjroofs @ exp#2&4 noted roof protection was not the required 70 feet wid
Apr 15, 2019 · Penalty $2,500
Resolve - Class - 1
28-407.1 failure to have license dob welder. at time of inspection observed worker on supported scaffold at 3rd fl level doing structural steel welding on exposure#1. when asked for dob license none was provide
Apr 15, 2019 · Penalty $2,500
Resolve - Class - 1
Sec. 3301.2 safety measures. at time of inspection observed vertical netting on roof level did not have zeno cable down to ground. netting @ as loose & debris could easily pass under & fall to ground. supported
Apr 15, 2019 · Penalty $2,500
Resolve - Class - 1
Sec. 3301.7 documents to be kept on site. at time of inspection asked competent person to provide enginered design drawing for approx 55 foot high supported scaffold at exp#1&3. none was provided. stop all use
Apr 15, 2019 · Penalty $2,500
Resolve - Class - 1
Sec. 3314.1 scaffold not maintained as per code. at time of inspectionobserved workers doing structure steel welding @ exp#1 3rd fl on an approx 55 foot high supported scaffold. noted that there were no guardra
Apr 15, 2019 · Penalty $2,500
Resolve - Class - 2
Failure to maintain documents on site at time of inspection on an active job site of a 5 story building i observed home made/fabricated platform at 1st story also platform inside elevator shaft with supported p
Mar 7, 2019 · Penalty $625
Resolve - Class - 1
Sec. 3303.14 failure to provide adequate drainage to prevent water accumulation at construction,demolition &/or excavation site. at time of inspection,i observed stagnent water at entire level of the basement a
Dec 17, 2018 · Penalty $625
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temporary construction-no guardrails #bc3301.2. at time of inspection,i observed guardrails throughout site. unsafe conditions not code compliant. obse
Dec 17, 2018 · Penalty $5,000
Resolve - Class - 1
Failure to maintain adequate housekeeping per section requirements. at time of inspection,i observed inadequate housekeeping at exp#3. observed steel beams & construction material at basement level. unsafe work
Dec 17, 2018 · Penalty $625
Resolve - Class - 1
Sec. 3308.5 failure to install or maintain vertical safety netting system as required. at time of inspection i observed the vertical safety netting was damaged & missing on the 1st fl unsafe work conditions.
Dec 17, 2018 · Penalty $2,500
Resolve - Class - 2
Failure to comply with the commissioner's order contained in summons/violation# 35360279n issued on 07/20/18 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01. for having constructio
Nov 24, 2018
Resolve - Class - 1
Failure to safeguard all persons and property affected by constructionoperation-noted: at the time of inspection observed construction ence open to the public (free access) w/out a security guard or monitor als
Jul 20, 2018 · Penalty $10,000
Resolve - Class - 1
Failure to maintain adequate housekeeping per section requirements noted: at the time of inspection observed at cellar level, exterior of foundation and elevator pit ther eis standing water, over 50% of
Jul 20, 2018 · Penalty $625
Resolve - Class - 1
Failure to safeguard all persons & property affected by construction operations. @ time of insp contractor failed to safeguard all property, bldg @ exp#2 & 3 were damaged by work performed by contractor. rem: s
Feb 27, 2017 · Penalty $5,000
Resolve - Class - 2
Construction superintendent failed to perform duties per rule. @ time of insp construction super michael benz failed to perform his duties. not on site during insp. last log book entry is 1/6/17. super is not k
Feb 25, 2017 · Penalty $400
Resolve - Class - 2
Job site fence not constructed pursuant to subsection. noted: fence atconstruction site under permit job #321159429-01-eq-fn expires 8/6/15.fence entrance gate is broken a plywood panel how pulled out from bott
Jul 15, 2015 · Penalty $400
Resolve - Class - 1
Failure to safeguard public & property effected by demo operations. noted: part of roof removed & some interior demo provided. no sidewalk shed & fence installed. remedy: stop all demo work,provide sws/fence.
Mar 18, 2009 · Penalty $6,000
Resolve - Class - 1
Failure to provide 24hr notice. noted: part of roof demolished & (zone) interior demo provided. no 24hr notice prior to start of demo day was provided. remedy: provide 24hr notice.
Mar 18, 2009 · Penalty $6,000
Resolve - Non-hazardous
Altered building occupied without a valid certificate of occupancy. noted: temporary certificate of occupancy #300914973 01 dated 02/06/03 expired 05/07/03 at time of inspection osp is being utilized also 2nd f
Aug 25, 2003 · Penalty $350
Resolve - Non-hazardous
57y15.
Jan 30, 2001 · Penalty $180
Resolve
Complaints
- Heating
Heat related
Feb 24, 2009 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Hotel (HS)
- Year built
- 2018
- Floors
- 5
- Residential units
- —
- Building area
- 52,500 ft²
- Lot area
- 19,831 ft²
- Zoning
- M1-4
- Community board
- 306
- Council district
- 39
- Block / lot
- 441 / 42
- Assessed value
- $13,005,900
- Landmark / historic district
- No
Questions about 561 President Street
Who owns 561 President Street?
The owner of record in NYC Department of City Planning PLUTO data is President Sai II , LLC.
Does 561 President Street have violations?
NYC HPD has no housing violations on record for this property.
Is 561 President Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 561 President Street built?
City records list 2018 as the year it was built.