251 Douglas Street
Brooklyn, NY 11217BBL 3-00412-0050Map
Owner of record: Gowanus Douglass Street LLC
251 Douglas Street is an elevator apartment building built in 2024 in Brooklyn, 11217. It has 261 residential units across 15 floors. The owner of record is Gowanus Douglass Street LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 0
- ECB violations
- 32
- HPD complaints
- 4
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 0
No DOB violations on record
ECB violations · 32
- Class - 2
At the time of my inspection for partial sws removal i observed work contrary to site safety plan-at exp#3/#4 adj property protection removed while work on railing above adj property not complete-temporary ple
Mar 31, 2026
Resolve - Class - 2
At time of inspection of a 15 story nb (approximately 26045 square feet) site closed and there were no construction activity.upon shouting and banging on fence to alert watchpersons and to verify compliance
Feb 1, 2026 · Penalty $2,500
Resolve - Class - 1
At 12:50pm observed workers working on supported scaffold against the commissioners order to stop all use of the support of scaffold as per complaint #3a42243, site safety personnel mary e lagana license #: 0
Dec 22, 2025 · Penalty $10,000
Resolve - Class - 1
Bc 3310.8.4 site safety manager mary e lagana license #: 002602 fail to notify the department of ongoing construction activities against swo also fail to perform her duty and allowed workers to continuing work
Dec 22, 2025 · Penalty $5,000
Resolve - Class - 2
At the time of inspection, observed supported pipe scaffold built at exposure 1 & 2 with the layout of the scaffold do not match the approved design drawings, the additional section erected in corner of exposur
Dec 21, 2025
Resolve - Class - 2
Bc 3303.3 time of my inspection of a 15 story new building, building approximately 223886 sq. feet. site closed and there were no construction activity. upon shouting at perimeter and banging on fence and door
Dec 21, 2025 · Penalty $2,500
Resolve - Class - 2
At time of inspection, delivery in process with lift obstructing pedestrian sidewalk. flagperson on site failed to provide sst card as required. presence of uncertified personnel directing public poses a seriou
Oct 4, 2025 · Penalty $2,500
Resolve - Class - 1
At time of my inspection active site observed work in process upon request no site safety manager were present on site code required a designated site safety manger must be present during active construction o
Aug 16, 2025 · Penalty $10,000
Resolve - Class - 2
Bc 3308.6 horizontal netting. at time of my inspection i observer horizontal netting missing or not extended at exp# 1 4 creates hazardous condition for debris and material to fall into public and property. s
Aug 16, 2025 · Penalty $2,500
Resolve - Class - 2
Bc3303.3 watchperson15 story new building, building approximately 32500 square feet. site closed and there were no construction activity. upon shouting at perimeter and banging on fence and door to alert watch
Jul 19, 2025 · Penalty $2,530
Resolve
Show 22 more ↓
- Class - 2
Inactive jobsite, with a building footprint (sq. ft.) 223886, walk jobsite perimeters, knock & called out, i observed no competent watch personnel as per bc 3303.7.7.6 a watchperson requirements of section 3303
Jul 5, 2025 · Penalty $2,500
Resolve - Class - 2
At the time of inspection for cd00004932, cn00083924, person acting aslift director, master rigger or master rigger foreman.; 28-424.2, comply with code; comply with notice of violation.
Jun 2, 2025
Resolve - Class - 2
At the time of the inspection for cd00004932, cn00083924, person acting as lift director, master rigger or master rigger foreman.; 28-424.2,comply with code; comply with notice of violation.
Jun 2, 2025 · Penalty $6,250
Active - Class - 2
Note: at the time of inspection at approximately 7:10 am, i observed construction work in progress contrary to the start time indicated on the approved after-hours variance (ahv) permit. the (after-hours varian
May 24, 2025 · Penalty $625
Resolve - Class - 1
Note: at time of inspection of a 13-story new building active construction work in progress, upon request, no site safety manager was present on site. code requires a designated site safety manager must be pres
May 24, 2025 · Penalty $10,000
Resolve - Class - 2
Foundation walls outboard insulation were installed with thickness 2" r-value-10 contrary to thickness 2 1/4" r-value-12.5 as per plan., conform work to approved construction documents/amendments; please go to
Apr 8, 2025
Resolve - Class - 2
Observe support scaffold at exp1 installed contrary to approve documents. eq -010.02 show a 2ft wide frame type on top of a w8x 10 beam that connect to top of support scaffold at lower sections. site has a 3'
Apr 3, 2025
Resolve - Class - 2
At the time of inspection observed articulating boom crane installed/parked/in use at vehicular lane lifting materials to 2nd fl of structure-fully closing the street(no dot permits)-upon checking the site safe
Mar 31, 2025
Resolve - Class - 1
Bc3301.2 - failure to institute safety measures. worker was injured by a fall through unprotected opening in the floor from 3rd story to 2nd story. no safety measures were provided to prevent incident. no guard
Mar 7, 2025 · Penalty $12,500
Resolve - Class - 2
Standing water accumulation . at the time of my inspection of a active job site with approximately 60 workers of various trades, i observed an accumulation of standing water in concrete planter at exposure acro
Dec 20, 2024
Resolve - Class - 2
3307.4.7 work or storage zones, failure to provide chain link fencing on barriers and solid 4 feet panel with chicken mesh above to protect and safeguard un authorized personnel from entering storage areas tha
Dec 20, 2024
Resolve - Class - 2
Bc 3308.6 missing horizontal netting. at the time of my inspection of a 13 story new building currently at 7 floor level i observed there were missing horizontal netting at exposure 2 as required creating a un
Dec 20, 2024 · Penalty $2,500
Resolve - Class - 2
Bc 3313.1 failure to comply with fire code. at time of my inspection i observed oxygen and acetylene tanks of gases on site , upon request for the fdny permits as require, i observed it to be expired creating
Dec 20, 2024 · Penalty $2,500
Resolve - Class - 1
No site-specific formwork design drawings present per 3301.17. as noted at time of inspection on an active construction site, 13 story new building, i observed formwork for columns and shear walls in place at 1
Oct 24, 2024 · Penalty $2,500
Resolve - Class - 1
While digging a test pit, excavator hit adjacent property at 233 nevins st damaging parapet and corner of one story setback at south east corner. earthwork permit #b00621061 ahv #b6271175, safeguard public and
Mar 2, 2024 · Penalty $10,000
Resolve - Class - 2
At the time of inspection, observed installed construction fence with expired permit. fence permit under b00661581 was expired on 02.15.2023. renew permit.
Feb 23, 2023 · Penalty $3,125
Resolve - Class - 2
At the time of inspection, project panel was not posted on the construction fence. g.c failed to comply with bc3301.9.
Feb 23, 2023 · Penalty $3,125
Resolve - Class - 2
At the time of inspection, observed installed construction fence with expired permit. fence permit under b00661629 was expired on 02.10.2023. renew permit.
Feb 23, 2023
Resolve - Class - 2
At the time of inspection, observed installed jersey barriers on exposure 1 and 4. the pedestrian walkway was not maintained as per code. minimum width of 5ft was not kept and walkway was obstructed by metal fe
Feb 23, 2023 · Penalty $2,400
Resolve - Class - 2
At the time of inspection, observed installed jersey barrier and sidewalk closure on exposure 1 and 4. upon request, no dot permit was provided and no permit was found on dot website. g.c failed to comply with
Feb 23, 2023 · Penalty $1,250
Resolve - Class - 1
At time of inspection , observed barrios on roadway provided to protect pedestrians was not maintained as required . the 5 feet required walkway was obstructed at exposures 1 / 2 with barrios observed across wa
Jan 9, 2023 · Penalty $1,250
Resolve - Class - 2
At time of inspection observed yodock barriers at street level at exposures 1 / 2 to protect the safety of pedestrians , but i observed that they were not provided and installed to manufacturer's specifications
Jan 9, 2023
Resolve
Complaints
- Heat/hot water
Entire building
Oct 23, 2026 · Apt BLDG
Open - Heat/hot water
Entire building
Oct 22, 2026 · Apt BLDG
Open - Heat/hot water
Entire building
Oct 22, 2026 · Apt BLDG
Open - Heat/hot water
Entire building
Oct 21, 2026 · Apt BLDG
Open
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D7)
- Year built
- 2024
- Floors
- 15
- Residential units
- 261
- Building area
- 250,496 ft²
- Lot area
- 28,500 ft²
- Zoning
- M1-4/R7X
- Community board
- 306
- Council district
- 39
- Block / lot
- 412 / 50
- Assessed value
- $16,068,150
- Landmark / historic district
- No
Questions about 251 Douglas Street
Who owns 251 Douglas Street?
The owner of record in NYC Department of City Planning PLUTO data is Gowanus Douglass Street LLC.
Does 251 Douglas Street have violations?
NYC HPD has no housing violations on record for this property.
Is 251 Douglas Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 251 Douglas Street built?
City records list 2024 as the year it was built.
How many apartments are in 251 Douglas Street?
It has 261 residential units and 262 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.