4747 Bronx Boulevard
Bronx, NY 10470BBL 2-05102-0027Map
Owner of record: 4747 Bronx Boulevard Realty LLC
4747 Bronx Boulevard is a hotel built in 1926 in Bronx, 10470. The owner of record is 4747 Bronx Boulevard Realty LLC. HPD has recorded 3 housing violations here, most recently on April 29, 2026.
- HPD violations
- 3
- DOB violations
- 37
- ECB violations
- 22
- HPD complaints
- 1
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 3
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 29, 2026
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 18, 2025
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 2, 2021
Closed — Violation dismissed
DOB building violations · 37
- Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2016 inspection/test
Sep 15, 2017
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 13, 2016
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Aug 10, 2016
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2014 inspection report
Oct 1, 2015
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2014 inspection/test
Jun 10, 2015
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2013 inspection report
Mar 3, 2015
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2012 inspection report
May 15, 2014
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2011 inspection report
Mar 1, 2013
Dob violation - dismissed
Show 27 more ↓
- Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2011 inspection/test
Oct 1, 2012
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2010 inspection/test
Dec 13, 2011
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2010 inspection report
Dec 13, 2011
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Vcat1-elevator annual inspection / test elevatorrequired
Oct 8, 2010
Dob violation - dismissed - Low pressure boiler boiler required
Lblvio-low pressure boiler boiler required
Dec 31, 2009
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 7, 2009
Dob violation - resolved - Immediate emergency anythingoptional
Imegncy-immediate emergency anythingoptional
Oct 16, 2009
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Feb 27, 2009
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 1, 2009
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 24, 2008
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 21, 2008
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 3, 2008
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Apr 2, 2007
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 19, 2007
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 5, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 10, 2006
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 6, 2006
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Oct 1, 2005
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 1, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 29, 2004
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 7, 2003
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 19, 2003
Dob violation - dismissed - Elevator elevatorrequired
2p170
Aug 15, 2002
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Elevator elevatorrequired
2p170
Mar 30, 2000
Dob violation - resolved - Elevator elevatorrequired
(51)restore to service so that a proper inspection can be made by this dept
Nov 9, 1988
Dob violation - resolved
ECB violations · 22
- Class - 2
Class 2: 1. category 1 test tag missing and not displaying required test information. as per asme a17.1 8.6.1.7. remedy: post valid category 1 test tag with current test date. 2. maintenance log book for curren
Aug 20, 2026
Resolve - Class - 1
Class 1 cease use: 1. door zone restrictor device found inoperative as per code asme a17.1/csa b44 - section 2.26.5. elevator car doors can be opened when the car is not within the designated door zone, creatin
Aug 20, 2026 · Penalty $1,250
Resolve - Class - 1
At the time of inspection observed new hot water heaters installed in the boiler room on the roof with no permits on file checked bis/dobnow contrary to pc 106.1 plumbing work, including water heater installati
Aug 20, 2026 · Penalty $2,500
Active - Class - 1
At the time of inspection observed painted sprinkler caps through out the building sprinkler caps are not to be painted as per fgc 903.3.3 obstructed locations in automatic fire sprinkler systems. it mandates t
Aug 20, 2026 · Penalty $2,500
Active - Class - 2
Failure to provide adequate grounding of electrical systems. observed in the main electrical and the point of entry no installation of electrode ground rod. in the main water meter room the main house water gro
Aug 20, 2026 · Penalty $2,400
Active - Class - 2
Miscellaneous violation of the electrical code technical standards. observed on the roof the hot water tank remote has no remote shutdown at the point entry / egress. must provide shut down at point of egress f
Aug 20, 2026 · Penalty $800
Active - Class - 2
1. category 1 test tag missing and not displaying required test information. as per asme a17.1 8.6.1.7. remedy: post valid category 1 test tag with current test date. 2. maintenance log book for current year mi
Aug 20, 2026 · Penalty $625
Active - Class - 2
Hole penetration with vents and pipes running through without fire-stopping., repair and/or replace
Sep 12, 2024
Resolve - Class - 1
No fresh air ventilation in the boiler room housing two gas fired water heaters. as per g.2.5 of the fgc ventilation. rooms containing appliances or equipment operating with gas pressure at or above 15 psig (10
Sep 5, 2024
Resolve - Class - 1
Observed throughout building painted sprinkler caps. as per 102.3 of the plumbing code. installations, both existing and new, and parts thereof shall be maintained in proper operating condition in accordance wi
Sep 5, 2024 · Penalty $312
Resolve
Show 12 more ↓
- Class - 2
Partial swo issued for supported scaffold pursuant 28-207.2 & posted on premises. sidewalk shed does not conform to approved plans. noted: at time of inspection sidewalk shed that installed on bullard ave(exp#3
Dec 15, 2017 · Penalty $1,250
Resolve - Class - 2
Failure to safeguard all persons & property affected by construction operations. noted: @ exp#1 e 242 street loading dock new entrance to bldg excavation being done no guardrails around excavation. temporary de
May 29, 2017 · Penalty $5,000
Resolve - Class - 2
Work does not conform to approved construction documents &/or approvedamendments. noted: dob approved plans job# 220425106 showing entrance onplan view no details for excavation, demolition of exterior wall, ne
May 29, 2017 · Penalty $500
Resolve - Class - 1
Work after hours w/o a variance permit contrary to 28-105.12.5. note: at time of inspection observed three male construction workers doing masonry work inside of bldg w/o a variance permit. rmdy:stop all after
May 22, 2016 · Penalty $800
Resolve - Class - 2
Failure to provide approved/accepted plans at job site at time of inspection note. at time of inspection three construction workers doing masonry work under permit #220485106 and no plans at site for inspection
May 22, 2016 · Penalty $250
Resolve - Class - 2
97**.failure to maintain elevator device.respondent failed to allow mandatory/annual routine inspection by the dept.or approved agency per 28-304-6.1 appendix of the bldg code.multiple attempts to gain access t
Aug 13, 2014 · Penalty $1,250
Resolve - Class - 2
97**. failure to maintain elevator device. respondent failed to provide proper access in order that the dept can perform periodic inspectionas per 28-304.6 & appendix k of the bldg code, respondent failed to
Mar 27, 2013 · Penalty $1,250
Resolve - Class - 1
Fail to maintain bldg walls or appurtenances. defect noted: at exp 3,4north & west walls, cracked & spalling bricked parapet wall, spalling cement stucco at curbs. remedy: maintain exterior bldg wall. provide s
Dec 11, 2009
Resolve - Class - 1
Failure to safe guard all persons & property affected by const. operations noted: work performed under permit # 220034237 location: rear of job site @ bullard ave dumping brick, mortar & other demolition debris
Nov 25, 2009 · Penalty $2,400
Resolve - Class - 1
Failure to provide sidewalk shed where required noted: permit # 220034237 posted. partial demolition or parapet observed from street. unableto determine if in scope of plans - no access to site. 80' of sidewalk
Nov 25, 2009 · Penalty $4,800
Resolve - Class - 1
Failure to maintain exterior building walls. defect is rusted sagging steel lintels. cracked & bulging brick work. eroded mortar joints. spalling cement stucco. at various locations. remedy: "immediately" erect
Oct 13, 2009 · Penalty $250
Resolve - Non-hazardous
35m 35o 37u 43u 54u 3507 fire extuinguisher s37 u16 43 54 u 16 city id tag
May 7, 1999
Resolve
Complaints
- Heat/hot water
Entire building
Aug 16, 2026 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Hotel (H4)
- Year built
- 1926
- Floors
- 2
- Residential units
- —
- Building area
- 43,700 ft²
- Lot area
- 21,885 ft²
- Zoning
- M1-1
- Community board
- 212
- Council district
- 11
- Block / lot
- 5102 / 27
- Assessed value
- $3,718,800
- Landmark / historic district
- No
HPD registration #228300, last renewed Dec 2, 2025.
Questions about 4747 Bronx Boulevard
Who owns 4747 Bronx Boulevard?
The owner of record in NYC Department of City Planning PLUTO data is 4747 Bronx Boulevard Realty LLC.
Does 4747 Bronx Boulevard have violations?
Yes. NYC HPD has recorded 3 housing violations at this property.
Is 4747 Bronx Boulevard rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 4747 Bronx Boulevard built?
City records list 1926 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.