2211 Throop Avenue
Bronx, NY 10469BBL 2-04372-0001Map
Owner of record: 1235 Pelham Parkway Realty LLC
2211 Throop Avenue is a hospital / health built in 1970 in Bronx, 10469. The owner of record is 1235 Pelham Parkway Realty LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 41
- ECB violations
- 13
- HPD complaints
- 2
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 41
- Construction other optional
Emergency work order due to cracked/spalling concrete belt course with exposed re-bar @ exp#1 e above public entry way. condition poses an imminent hazard to public entering & existing facility/bldg. remedy: immediately take & provide adequ safe measures to secure & protect the public & install public protection under supervision nys licens profes
Oct 16, 2024
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Residential elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Dec 17, 2021
Dob violation - active - Residential elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Dec 17, 2021
Dob violation - active
Show 31 more ↓
- Elevator elevatorrequired
E-elevator elevatorrequired
Dec 12, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 12, 2019
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 20, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 20, 2018
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 16, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 16, 2017
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2015 inspection report
Feb 24, 2017
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 21, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 21, 2012
Dob violation - resolved - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 3, 2012
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Jan 1, 2012
Dob violation - dismissed - Low pressure boiler boiler required
Lblvio-low pressure boiler boiler required
Dec 31, 2009
Dob violation - dismissed - Low pressure boiler boiler required
Lblvio-low pressure boiler boiler required
Dec 31, 2009
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 7, 2009
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 1, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 8, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 8, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 6, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 6, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 15, 2004
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 15, 2004
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 10, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 10, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 29, 1995
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 29, 1995
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 17, 1993
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 17, 1993
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
May 21, 1990
Dob violation - resolved
ECB violations · 13
- Class - 1
Failure to maintain building in a code-compliant manner. note: at timeof inspection observed same conditions as stated in violation #35689351m dated 12-10-2024 states observed spalling concrete at mutliple loca
Jun 18, 2025 · Penalty $7,500
Active - Class - 2
Failure to submit an acceptable required cycle 9c report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control #919449. remedy: submit acceptable requ
Apr 8, 2025 · Penalty $2,500
Active - Class - 1
Failure to maintain building exterior facade and appurtenances.note:attime of inspection,it was observed spalling concrete at belt course atmultiple locations at exposure 1(east)& exposure 3(west elev)inadequat
Dec 10, 2024 · Penalty $2,500
Active - Class - 2
Failure to maintain bldg exterior facade and appurtenances. note: at time of inspection, i observed cracked/spalled concrete belt course multi loc at exp #1 east, #3 west. exp #4 north spalling brick/mortar by
Oct 16, 2024 · Penalty $1,250
Active - Class - 1
Failure to maintain bldg exterior facade and appurtenances. note: at time of inspection, i observed cracked/spalling concrete belt course/concrete vertical members multi loc. at exp #1 east, #3 west.-exp #4 nor
Oct 16, 2024 · Penalty $2,500
Active - Class - 1
Work without permit.premises under alt-2 job #220258156 at the time of inspection installed emergency gas shut off valve kitchen of cellar level found no plumbing permit in dob record.additionally noted job #20
Mar 28, 2019
Resolve - Class - 2
Work does not conform to approved construction documents. @ time of insp observed an active construction site w/ rebar work in progress @ foundation stage. during insp noted that the excavation @ exp#4 does not
Jul 28, 2017
Resolve - Class - 2
Job site fence not constructed or maintain pursuant to subsection. @ time of insp observed an active construction site w/ rebar work in progress @ foundation stage. during insp noted that the fence was bended o
Jul 28, 2017
Resolve - Non-hazardous
39h11,35y2,48k10,48h12,50y11,57k10, 39h11- adjust rope tension
Apr 11, 2000 · Penalty $350
Resolve - Non-hazardous
22y2,2202,57k10
Apr 11, 2000 · Penalty $350
Resolve
Show 3 more ↓
- Non-hazardous
11x 16h 22d 30o 35i 57z 75u 11x11 cartop 16h12 1 2 3 4 th fls 30 o 2 too much lint 35 i 11 leaku roof 57z 9 water in pit
May 27, 1999 · Penalty $180
Resolve - Non-hazardous
15l 16h 22d 22o 30o 35i 37g 57z 75u 15 l 11 not slf closing 2n fl 16 h 12 1 2 3 4 5 fls 22 d 6 properly secure 22 0 2 clean car top 3 00 z clean shaft 35 i 11 roof leak 37 g 12 improper fused
May 27, 1999 · Penalty $180
Resolve - Non-hazardous
Install metal screws at breeching sections. clean gas burners. replace metal chimney corroded+defective.
Jun 29, 1989 · Penalty $150
Resolve
Complaints
- Heating
Heat related
Nov 7, 2008 · Apt BLDG
Close - Heating
Heat related
Nov 4, 2008 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Hospital / health (I6)
- Year built
- 1970
- Floors
- 6
- Residential units
- —
- Building area
- 62,212 ft²
- Lot area
- 33,375 ft²
- Zoning
- R4-1
- Community board
- 211
- Council district
- 13
- Block / lot
- 4372 / 1
- Assessed value
- $5,153,850
- Landmark / historic district
- No
Questions about 2211 Throop Avenue
Who owns 2211 Throop Avenue?
The owner of record in NYC Department of City Planning PLUTO data is 1235 Pelham Parkway Realty LLC.
Does 2211 Throop Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 2211 Throop Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 2211 Throop Avenue built?
City records list 1970 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.