1878 Cross Bronx Expwy

Bronx, NY 10472BBL 2-03880-0036Map

Owner of record: Sunset Beach Realty,

1878 Cross Bronx Expwy is a mixed residential and retail building built in 1925 in Bronx, 10472. It has 2 residential units across 3 floors. The owner of record is Sunset Beach Realty,. HPD has recorded 19 housing violations here, most recently on December 3, 2024. 14 of the 19 most recent violations are still open.

HPD violations
19
DOB violations
31
ECB violations
11
HPD complaints
36

What to know

Concern
2 open Class C

Immediately hazardous issues among recent violations are still open.

Good
Last violation Dec 3, 2024

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 19

  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Dec 3, 2024

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 28, 2023

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 17, 2022

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Mar 16, 2022

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 30, 2018

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective wood floor. at public hall, 1st story

    Jul 21, 2010

    Open — Nov sent out
  • B

    Properly secure the loose hand rail. at public hall, 2nd story

    Jul 21, 2010

    Open — Nov sent out
  • B

    Properly repair the broken or defective lower sash window counter balance. in the 2nd room from east at south located at apt 3, 3rd story, 1st apartment from west at north

    Jul 21, 2010 · Apt 3

    Open — Nov sent out
  • B

    Abate the nuisance consisting of mice in the entire apartment located at apt 3, 3rd story, 1st apartment from west at north

    Jul 21, 2010 · Apt 3

    Open — Nov sent out
  • B

    Provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules. in the entire apartment located at apt 3, 3rd story, 1st apartment from west at north

    Jul 21, 2010 · Apt 3

    Open — Nov sent out
Show 9 more ↓
  • B

    Properly repair the broken or defective window frame. in the bathroom located at apt 3, 3rd story, 1st apartment from west at north

    Jul 21, 2010 · Apt 3

    Open — Nov sent out
  • B

    Repair the broken or defective plastered surfaces and paint in uniform color at ceiling, and walls. in the bathroom located at apt 3, 3rd story, 1st apartment from west at north

    Jul 21, 2010 · Apt 3

    Open — Nov sent out
  • B

    Properly repair the broken or defective base cabinet. in the kitchen located at apt 3, 3rd story, 1st apartment from west at north

    Jul 21, 2010 · Apt 3

    Open — Nov sent out
  • B

    Properly repair with similar material the broken or defective wood floor. in the kitchen located at apt 3, 3rd story, 1st apartment from west at north

    Jul 21, 2010 · Apt 3

    Open — Nov sent out
  • B

    Provide adequate lighting for consisting of 60 watts. at public hall, 1st story

    Jul 21, 2010

    Open — Nov sent out
  • A

    Refit lower window sashes in the entire apartment located at apt 3, 3rd story

    Sep 1, 2009 · Apt 3

    Open — Nov sent out
  • B

    Provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules. in the entire apartment located at apt 3, 3rd story

    Sep 1, 2009 · Apt 3

    Open — Nov sent out
  • C

    Properly repair the broken or defective door hinge on fire rated door yard to building in the entrance.

    Sep 1, 2009

    Open — Nov sent out
  • C

    Abate the nuisance consisting of uncapped radiator valve at public hall, 1st story

    Dec 11, 2007

    Open — Nov sent out

DOB building violations · 31

  • Construction other optional

    Emergenc work order.bldg leaning towards exp4(cross bronxexpressway) exp 1/4 crnr saggng@2nd to roof above cantilevered above entrance.exp2 wall bulng out.1st to 3rdfl sloped.exp3wall prtlly open.ownr to immed rtain nyspe,demo gc,asbestsos gc.1.nyspe shall sbmt means&methds for full demo,by hand,per dep guidelines

    Feb 12, 2025

    Dob violation - active
  • Construction other optional

    Emergency work order.bldg leaning twrds exp4(cross bronx expwy).exp1/4 crnr sagnng@2nd to roof@cantilever above entrance.exp2wall bulgng out int relievng wall@1st to 3rdfls severely deteriorated.ownr to rtain gc to immed install tghtbrd fence around ent property.fence shall extend to curbline@cross bx expwy

    Feb 12, 2025

    Dob violation - active
  • Structurally compromised building none

    Failure to submit an acceptable inspectn rpt for structurally compromised bldg.

    Jul 15, 2023

    Dob violation - dismissed
  • Construction other optional

    Ftm.due to 3alarm fire on 5/31/23,exp4 wall abuttng tireshop was fire dmgd&prtlly open.unrelatd to fire,main 3story bldg dtriortd thruout.w/ prtlly cllpsd ceilng/wall finshs.dtriortd flr jst.ownr to rtain nys pe to eval ent bldg&file rpair dwgs w/dob.bldg to be perm rprd undr prmt strtng 8/21/23&cmpltd/sgnd off by sept 29,2023

    Jul 12, 2023

    Dob violation - active
  • Construction other optional

    Emergency work.due to fire on 5/30 to 5/30 to 5/31,the 1story tireshop was fire damaged w/the exp3 half of the roof partially collapsed remaining steel girders&posts,wood roof joists,&masonry walls were strctrlly cmpromised&at risk of collapse.ownr to rtain nys pe,demo endorsd gc,& asbestos cntrctr to1.immed demo 1story ext tire shop&flow

    May 31, 2023

    Dob violation - active
  • Construction other optional

    Emergency work.due to fire on 5/31/23,the 1st tireshop was fire damagd w/the exp3 half of the roof prtlly cllpsd.remaining roof steel girders &posts,wood roof joists,&masonry walls were strclly compromised.ownr to rtain gc to erect tghtbrd fence to secure the entire property,as req'd.file a job w/dob in 2 days from start of work

    May 31, 2023

    Dob violation - active
  • Immediate emergency anythingoptional

    1) seal all accessible openings to aviod unauthorized access 2)install approximately 74 feet of construction fence along exposure #1 and #3 and approximately 50 feet along exposure#2 and #4

    May 31, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 9, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 4, 2019

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2016 inspection report

    Apr 6, 2018

    Dob violation - active
Show 21 more ↓
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2015 inspection report

    Feb 24, 2017

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2014 inspection report

    Oct 1, 2015

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2013 inspection report

    Mar 3, 2015

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2012 inspection report

    May 15, 2014

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2011 inspection report

    Mar 1, 2013

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2010 inspection report

    Dec 13, 2011

    Dob violation - active
  • Low pressure boiler boiler required

    Lblvio-low pressure boiler boiler required

    Dec 31, 2009

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 1, 2009

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 3, 2008

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 6, 2006

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 31, 2005

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 19, 2003

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 7, 2000

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 10, 1997

    Dob violation - active
  • Construction other optional

    C-construction other optional

    Oct 21, 1994

    Vw*-violation - work w/o permit dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 17, 1993

    Dob violation - active

ECB violations · 11

  • Class - 2

    Observed inactive site with construction fence @ perimeter of jobsite inadequately maintained. throughout entire perimeter of construction fence there is graffiti painted all over not maintain hunter green and

    Jun 3, 2025 · Penalty $5,000

    Active
  • Class - 2

    Inactive demo site observed construction fence installed at all exp. fn covered in excessive amount of graffiti, obscuring some viewing panels. majority of viewing panels missing required acrylic paneling or eq

    Apr 25, 2025 · Penalty $5,000

    Active
  • Class - 1

    Failure to maintain bldg in code compliant manner. at the time of inspection & observed at exp#2&3 siding is missing exposed to orignal siding at exp#2 wall bulging between 1st & 2nd fl broken windows.

    Dec 6, 2019 · Penalty $6,250

    Resolve
  • Class - 1

    Failure to maintain bldg in code compliant manner manner at all exposures missing siding holes rotten wood frame. remedy: comply w/code.

    Oct 8, 2019

    Resolve
  • Class - 1

    Failure to maintain bldg in code compliant manner. noted: @ exp#3 wallbulging between 1st & 2nd fl at exp#3,4&2 missing/lease & hanging siding at exp#4 plywood detached hanging w/rotten wood frame,holes/opening

    Aug 24, 2019 · Penalty $6,250

    Resolve
  • Class - 1

    Failure to maintain bldg in code compliant manner. noted: at time of inspection i observed at exp#3 wall has bulging between 1st & 2nd fl exp#4 has missing siding along w/rotted wood(drove)windows & missing win

    Jun 17, 2019 · Penalty $12,500

    Active
  • Class - 1

    Failure to maintain building in code compliant manner. noted:at time of inspection,observed exposure#3 wall has bulging between 1st and 2nd fl,exposure#4 has missing siding along w/ rotted wood above windows an

    Apr 14, 2019 · Penalty $312

    Resolve
  • Class - 2

    B265 as per class 2 (b265) 28-303.7 failure to file a complete boilerinspection as per dob record submit a current bo9 inspection report.

    Mar 10, 2017 · Penalty $500

    Active
  • Hazardous

    Illegal use in a r5 zoning district tire repair for auto motive vehicle repair shop name cross bronx tire & wheel flat fix. remedy:discontinue illegal use.

    Jul 21, 2006

    Resolve
  • Non-hazardous

    Work without a permit. work noted: erected a block structure approx. 60'-0"long by 8'-0"high. remedy: obtain all necessary permit.

    Jun 2, 1999 · Penalty $2,500

    Resolve
Show 1 more ↓
  • Non-hazardous

    Work without a permit. erected a block structure approx 60' long by 8' high

    Nov 13, 1997 · Penalty $2,500

    Resolve

Complaints

  • Electric

    Electric-supply

    Jul 20, 2010 · Apt 3

    Close
  • Electric

    Electric-supply

    Jul 20, 2010 · Apt 3

    Close
  • General

    Floor

    Jul 20, 2010 · Apt 3

    Close
  • General

    Cabinet

    Jul 20, 2010 · Apt 3

    Close
  • General

    Mold

    Jul 20, 2010 · Apt 3

    Close
  • Paint/plaster

    Wall

    Jul 20, 2010 · Apt 3

    Close
  • General

    Windows

    Jul 20, 2010 · Apt 3

    Close
  • General

    Windows

    Jul 20, 2010 · Apt 3

    Close
  • General

    Windows

    Jul 20, 2010 · Apt 3

    Close
  • General

    Floor

    Jul 20, 2010 · Apt 3

    Close
Show 26 more ↓
  • Nonconst

    Vermin

    Jul 20, 2010 · Apt 3

    Close
  • Nonconst

    Vermin

    Jul 20, 2010 · Apt 3

    Close
  • Heating

    Heat related

    Nov 30, 2009 · Apt 3

    Close
  • Heating

    Heat related

    Nov 29, 2009 · Apt 3

    Close
  • Heating

    Heat related

    Nov 6, 2009 · Apt 3

    Close
  • Heating

    Heat related

    Aug 30, 2009 · Apt 3

    Close
  • Electric

    Electric-supply

    May 6, 2009 · Apt 2

    Close
  • Heating

    Heat related

    Nov 18, 2008 · Apt 3

    Close
  • Heating

    Heat related

    Nov 15, 2008 · Apt 2

    Close
  • Heating

    Heat related

    Jan 21, 2008 · Apt 3

    Close
  • Appliance

    Electric/gas range

    Jan 21, 2008 · Apt 3

    Close
  • Heating

    Heat related

    Jan 3, 2008 · Apt 3FL

    Close
  • Appliance

    Electric/gas range

    Jan 3, 2008 · Apt 3FL

    Close
  • Plumbing

    Basin/sink

    Jan 3, 2008 · Apt 3FL

    Close
  • Heating

    Heat related

    Dec 5, 2007 · Apt BLDG

    Close
  • Plumbing

    Water supply

    Sep 27, 2007 · Apt 2

    Close
  • Plumbing

    Water supply

    Sep 27, 2007 · Apt 2

    Close
  • Plumbing

    Water supply

    Sep 20, 2007 · Apt 2

    Close
  • Heating

    Heat related

    Aug 15, 2007 · Apt 2

    Close
  • Heating

    Heat related

    Apr 10, 2007 · Apt 2

    Close
  • Heating

    Heat related

    Mar 6, 2007 · Apt 2

    Close
  • Heating

    Heat related

    Jan 27, 2007 · Apt 2

    Close
  • Heating

    Heat related

    Nov 8, 2006 · Apt 2

    Close
  • Heating

    Heat related

    Nov 4, 2006 · Apt 2

    Close
  • Heating

    Heat related

    Oct 31, 2006 · Apt 2

    Close
  • Heating

    Heat related

    Oct 23, 2006 · Apt 2

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Mixed residential and retail building (S9)
Year built
1925
Floors
3
Residential units
2
Building area
4,800 ft²
Lot area
7,200 ft²
Zoning
R5
Community board
209
Council district
18
Block / lot
3880 / 36
Assessed value
$506,700
Landmark / historic district
No

HPD registration #710418, last renewed Sep 9, 2025.

Questions about 1878 Cross Bronx Expwy

Who owns 1878 Cross Bronx Expwy?

The owner of record in NYC Department of City Planning PLUTO data is Sunset Beach Realty,.

Does 1878 Cross Bronx Expwy have violations?

Yes. NYC HPD has recorded 19 housing violations at this property.

Is 1878 Cross Bronx Expwy rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 1878 Cross Bronx Expwy built?

City records list 1925 as the year it was built.

How many apartments are in 1878 Cross Bronx Expwy?

It has 2 residential units and 5 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.