roofy

1410 Story Avenue

Bronx, NY 10473BBL 2-03622-0018Map

Owner of record: 49-47 31st Street LLC

1410 Story Avenue is a theatre built in 2017 in Bronx, 10473. The owner of record is 49-47 31st Street LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
9
ECB violations
16
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 9

  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 in 2022

    Apr 22, 2023

    Dob violation - dismissed
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Apr 29, 2021

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2020

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 29, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 29, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 29, 2020

    Dob violation - resolved
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2020

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Oct 20, 2018

    Vp*-violation unserved ecb- dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jun 13, 2018

    Dob violation - dismissed

ECB violations · 16

  • Class - 1

    At time of my inspection i observed worker on top of an object approx 7'ft to 8'ft in height.they used an a-frame ladder against manufacturers specs.the ladder was in a closed position against the object with t

    Dec 20, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    New building topped and enclosed,i observed inadequate cable guard rail netting loose and poorly maintained said guardrail cable were sagging and loose at exposure one.no guardrails were in place at excavation

    Dec 20, 2018 · Penalty $2,500

    Resolve
  • Class - 2

    New building 1 story with mezzaonine topped and enclosed i observed lworker standing on a 2 tier pipe frame supported scaffold.scaffold did not have ladder access to platform.i requested work to provide proof f

    Dec 20, 2018 · Penalty $625

    Resolve
  • Class - 2

    28-105.12.1 performing construction work outside permitted hrs & days w/o obtaining an after-hours work variance.@ time of inspection it wasobserved that the contractors ha an afterhours variance for plumbing,h

    Oct 20, 2018 · Penalty $620

    Resolve
  • Class - 1

    Failure to have a site safety manager present as required.@ time of inspection it was observed that the site safety manager, michelle a. depew was not on site,daily log of ssm indicated that she was on-site fro

    Oct 20, 2018

    Resolve
  • Class - 1

    Material false statement- the respondent is identified as the applicant of record for job# 220452427. documents signed & sealed by the applicant indicate that the bldg has a footprint greater than 100,000 sq.ft

    May 14, 2018 · Penalty $25,000

    Resolve
  • Class - 1

    Material false statement- the respondent is idenitified as the applicant of record for job# 220468312. documents signed & sealed by the respondent indicate that the bldg has a footprint greater than 100,000 sq.

    May 14, 2018 · Penalty $25,000

    Resolve
  • Class - 2

    Sec. 3305.2.4 placing of structual members: note at time of inspectionof an incident of a worker falling approx 30ft along rhe placement of structual(member)on rooif level. while roof joist was being placed the

    May 10, 2018 · Penalty $625

    Resolve
  • Class - 1

    Failure to safegurd all persons affected by construction activity. mobile crane on site cv #1098/17 cd 4145. hmo thomas cunningham lic#10051 exp 12/18/20 class c1 trainer manuel herrera lic#10041 exp 2/27/20

    May 10, 2018 · Penalty $10,000

    Resolve
  • Class - 2

    Filed certificate form, application exc containing a material of false statement. note: @ time of insp a new bldg @ roof level. checking permit application in bis observed that foot print of bldg is over 100,00

    May 10, 2018 · Penalty $625

    Resolve
Show 6 more ↓
  • Class - 1

    Failure to safeguard all persons affected by construction operations. mobile crane cn 1098/17 cd 4145 on site hmo thomas cunningham lic #10051 exp 12/18/20 close c1 trainer manuel herrera lic 10041 exp 2/27/20

    May 10, 2018

    Resolve
  • Class - 2

    Sec. 3301.02(b)(c) failure to designate & or have construction superintendent present at site when required. note at time of inspection of a1 sty commercial bldg at roof level. i ask for construction super on

    May 10, 2018 · Penalty $625

    Resolve
  • Class - 2

    Sec: bc3310.4. site safety monitoring program. note: @ time of insp of a 1 story commercial bldg @ roof level w/ foot print of over 100,000 sq.ft, bldg was not classified as a major bldg due to false informatio

    May 10, 2018 · Penalty $620

    Resolve
  • Class - 2

    Failure to provide approved construction documents nb#2204524271n an energy compliance inspection i observed construction work without having construction docments at time of inspection.

    Apr 23, 2018 · Penalty $250

    Resolve
  • Class - 1

    1rcny 3319-02(c)(i) respondent failed to have a lift director on site as required. mobile crane cn #1098/17 cd #4145 was on site and being operated by hmo joseph pascalli lic#9374 class a lic exp 5/8/20. the d

    Mar 12, 2018

    Resolve
  • Class - 1

    1rcny 3319-02(c)(i) failure to have a lift director on site. at the time of inspection mobile crane cn #1098/17 cd #4145 was being in operation by hmo joseph pascalli lic #9374 class a lic. exp 5/8/20. no lift

    Mar 12, 2018 · Penalty $2,500

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Theatre (J6)
Year built
2017
Floors
2
Residential units
—
Building area
167,315 ft²
Lot area
176,470 ft²
Zoning
M1-1
Community board
209
Council district
18
Block / lot
3622 / 18
Assessed value
$3,075,300
Landmark / historic district
No

Questions about 1410 Story Avenue

Who owns 1410 Story Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 49-47 31st Street LLC.

Does 1410 Story Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 1410 Story Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 1410 Story Avenue built?

City records list 2017 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.