872 Bronx Park South
Bronx, NY 10460BBL 2-03124-0067Map
Owner of record: Hp Bronx Park South HDFC, INC
872 Bronx Park South is an elevator apartment building built in 2024 in Bronx, 10460. It has 82 residential units. The owner of record is Hp Bronx Park South HDFC, INC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 2
- ECB violations
- 18
- HPD complaints
- 2
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 2
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 26, 2024
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 28, 2017
Dob violation - dismissed
ECB violations · 18
- Class - 2
At time of inspection of a 8 story new building at roof, building approx 9,689.55 feet. site was closed and there were no construction activity. upon shouting at perimeter and banging on fence and door to alert
Aug 9, 2025 · Penalty $2,500
Active - Class - 2
Exp4 sws removed prematurely prior completion exterior work exp4.bc3307.6.2,bc3307.6.3 stipulates sidewalk,walkway,pathway accessible by public and within perpendicular distance from new structure,sws shall be
Jun 17, 2025 · Penalty $2,400
Resolve - Class - 2
At time of inspection observed active suspended scaffolds. upon reviewing manufacture specs for sky climber platform, observed missing top front rail on all platforms installed. a total of 5 platforms at expos
Jun 11, 2025 · Penalty $1,250
Resolve - Class - 2
At time of inspection observed active construction activities on site. upon inspecting exp. 4 notice uninstalled windows with inadequate guardrail system on all floors. guardrails where not secure they were onl
Jun 11, 2025 · Penalty $2,500
Resolve - Class - 1
At time of inspection observed multiple suspended scaffold at exp. 4 and 1. upon reviewing approved drawings notice drop locations does not conform from 4 location 2 were created on multipoint scaffold. a 2 poi
Jun 11, 2025 · Penalty $2,500
Resolve - Class - 1
At time of inspection observed several multipoint scaffolds suspended and in use. upon inspecting multipoint scaffolds at corner of exposure 1 and 4 notice scaffolds have angles to cover round corner. as per do
Jun 11, 2025 · Penalty $5,000
Resolve - Class - 2
At time of inspection observed sidewalk shed installed at exp. 1 and partially at exp. 4. at exp. 1 notice a section with cross braces every 5 bay as per sws drawings cross braces have to be installed every 4 b
Jun 11, 2025
Resolve - Class - 2
Observed workers on 7th floorwork deck with alternate means of fall protection which consist of anchor points that attach into drilled holes in precast concrete. upon request for the manufacturer specs for the
Nov 13, 2024 · Penalty $1,250
Resolve - Class - 2
28-110.2 phased site safety plans- observed ongoing crane operations @ exposure 1 street level of jobsite. upon review of provided site safety plan, the current phase of crane operations does not reflect the sw
Nov 13, 2024 · Penalty $1,250
Resolve - Class - 2
Observed ongoing crane operations @ exposure 1 of jobsite. the awning of the adjacent property @ exposure 2 does not meet required 20ft protection as per code, approximately 5 ft of protection is in place at ti
Nov 13, 2024 · Penalty $5,000
Resolve
Show 8 more ↓
- Class - 1
3301.4.1 inspection of equipment where the code does not specifically require an inspection-observed workers installing cmu @ leading edge & multiple locations attached @ make-shift system made of iron & nuts w
Sep 25, 2024 · Penalty $5,030
Resolve - Class - 2
Observed ongoing cmu operations @ exposure 2 of jobsite. jobsite provided access agreement from adjacent property to provide control access. the jobsite is required to provide an alternate means/method of prote
Sep 25, 2024 · Penalty $5,030
Resolve - Class - 2
3301.1.1 responsibility for safety- observed alleyway locked from exterior, while interior obstructed by construction material and supported pipe scaffold @ half the way preventing a clear passage in case of em
Sep 25, 2024 · Penalty $2,530
Resolve - Class - 1
At time of inspection i observed active jobsite at basement level with standing water more then 3 inches inside elevator shafts creating a health hazard as a breeding ground for mosquitoes and other rodents.pro
Jun 24, 2024 · Penalty $2,500
Resolve - Class - 2
Bc 3308.7 guardrail system: a t time of inspection i observed active jobsite with scaffold system erected at basement level with missing guardrail system creating a hazard for workers and persons accessing scaf
Jun 24, 2024 · Penalty $5,000
Resolve - Class - 2
At time of inspection observed active job site, currently on excavation/foundation phase. upon requesting sst card to workers on site blas a bonilla provide a sst card with a revoked result after scanning it.
Apr 16, 2024 · Penalty $2,500
Resolve - Class - 2
At time of inspection observed active jobsite currently discharging water to street sewer. upon requesting a discharge permit it was not provided. site is currently on excavation/foundation phase, upon request
Apr 16, 2024 · Penalty $1,250
Resolve - Class - 1
Failure to provide notification prior to start of demolition. at time of inspection noted on bis that the required commencement notification to the dob's was not submitted as per code requirement. remedy: compl
Apr 3, 2017 · Penalty $1,200
Resolve
Complaints
- Heat/hot water
Entire building
Feb 20, 2026 · Apt BLDG
Close - Heating
Heat related
Jan 28, 2005 · Apt 2
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D1)
- Year built
- 2024
- Floors
- —
- Residential units
- 82
- Building area
- 65,939 ft²
- Lot area
- 14,908 ft²
- Zoning
- R7-1
- Community board
- 206
- Council district
- 15
- Block / lot
- 3124 / 67
- Assessed value
- $2,058,750
- Landmark / historic district
- No
Questions about 872 Bronx Park South
Who owns 872 Bronx Park South?
The owner of record in NYC Department of City Planning PLUTO data is Hp Bronx Park South HDFC, INC.
Does 872 Bronx Park South have violations?
NYC HPD has no housing violations on record for this property.
Is 872 Bronx Park South rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 872 Bronx Park South built?
City records list 2024 as the year it was built.
How many apartments are in 872 Bronx Park South?
It has 82 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.