1745 West Farms Road
Bronx, NY 10460BBL 2-03015-0025Map
Owner of record: 1745 West Farms Road LLC
1745 West Farms Road is an elevator apartment building built in 2022 in Bronx, 10460. It has 40 residential units across 8 floors. The owner of record is 1745 West Farms Road LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 15
- ECB violations
- 31
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 15
- Construction other optional
Failure to maintain building in a code compliant manner.as noted at th e time of inspection,i observed on exp1 east elev,cracks & spalling in building material at several locations.also open & unfinished windows on exp1 east elev with no netting or other safety measure covering win dow opening to prevent stuff from falling.remedy:repair or replace
Jun 26, 2026
Dob violation - active - Construction other optional
Borough commissioner-notice of order to stop work immediately due to construction superintendandt withdrawal #220698555. unable to verify the percentage of work completed
Oct 27, 2025
Dob violation - dismissed - Construction other optional
Failure to maintain building exterior facade in a code compliant manner. note at time of inspection observed multiple missing pannels at all exp# 1,2,3,4 multiple areas of spalling coating/damaged pannels multiple locations water damage prsent on facade. remedy: repair and replace
Oct 7, 2025
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 11, 2024
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2024
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 22, 2024
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Feb 7, 2024
Dob violation - dismissed - Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Dec 1, 2023
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 2, 2023
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2023
Dob violation - active
Show 5 more ↓
- Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2023
Dob violation - active - Construction other optional
Borough commissioner swo for superintendent of construction withdrawal for job#240286873.
Oct 17, 2022
Dob violation - dismissed - Construction other optional
Borough commissioner swo due to withdrawal of superintendent of construction for job 220 698555.
Oct 17, 2022
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 22, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 22, 2021
Dob violation - dismissed
ECB violations · 31
- Class - 2
Observed jobsite approximately 7 stories high with incomplete exterior work all exposures. at exposure 1 the pedestrian walkway has no sidewalk shed provided for protection against construction operations as re
Jul 28, 2026 · Penalty $2,400
Active - Class - 2
3314.1- observed supported scaffolding installed @ expo 4 of jobsite approx. 78 ft in height. the scaffold is not adequately maintained w/out debris netting installed as required per approved plans, loose plank
Jan 22, 2026 · Penalty $2,500
Resolve - Class - 2
Observed construction fence installed around perimeter of jobsite. upon review of dob records the permit of construction fence is expired as of 1-9-2026.renew permit
Jan 22, 2026
Resolve - Class - 2
3314.1- observed supported scaffold installed @ expo 4 of jobsite approx. 78 ft in height. scaffolding is not maintained as per code requirements during severe weather advisory notice, w/out debris netting ins
Oct 30, 2025 · Penalty $2,500
Resolve - Class - 1
Failure to designate and/or have a construction superintendent presentat jobsite as required.as noted:at time of inspection at an active jobsite of a proposed 8 story building already at the bulkhead level.obse
Oct 21, 2025 · Penalty $12,500
Resolve - Class - 1
Atoi observed building currently 10 story,no standpipe ready,reviewed architectural and structural plans reveal building height 7 story to be 80 feet from ground level,bc 3303.8 stipulates working deck reaches
Apr 14, 2025 · Penalty $5,000
Resolve - Class - 1
Atoi observed building currently at 10 story,reviewed architectural and structural plans revealed total stories building to be 11.definiton major building per section 3302,proposed building 10 or more stories i
Apr 14, 2025
Resolve - Class - 1
Unlawfuul continued work while on notice of a stop work order. as noted at time of inspection on an active construction site 8 story new building completed to roof level where a partial work order was issued 07
Mar 17, 2025 · Penalty $10,030
Active - Class - 2
Observed nb 8 story building,count stories from west farms road revealed walking floor at 10 story,reviewed app.x01126649 temp hoist installation which none was observed as per plans location and throughout per
Mar 16, 2025 · Penalty $6,250
Active - Class - 2
Observed 8 story nb,counting stories from west farms road revealed walking floor at 10 story,missing horiz.nets or scaffold alter. per bc3308.6,bc3308.6.1.4 stipulates construction new building occurs height gr
Mar 16, 2025 · Penalty $10,000
Active
Show 21 more ↓
- Class - 2
Observed nb 8 story building,counting stories from west farms road revealed walking floor at 10 story,reviewed zd in nb- 220698555 reveal total height of building from grade 111 feet,bc3307.6.3 stipulates work
Mar 16, 2025 · Penalty $10,000
Active - Class - 1
At time of my inspection of a active jobsite with a partial stop work order of all street operation at exp#1 .i noticed street operation of a flatbed truck hoisting cmu block material up to the 3rd floor level
Oct 1, 2024 · Penalty $5,000
Resolve - Class - 1
At time of my inspection of a proposed 7 story building at 5th floor level. upon reviewing approved crane operation plan and site safety plan.i noticed overhead protection indicated on plans missing at exposur
Oct 1, 2024 · Penalty $2,500
Resolve - Class - 2
I noticed a makeshift platform made by 3 wooden pallets and wood on top of a pipe scaffold used to stand on while receiving material when hoisted into building.upon rquesting for design drawing none was prove
Oct 1, 2024 · Penalty $5,000
Resolve - Class - 1
At time of my inspection i noticed at 2nd floor level a gas container filled with gasoline on top of wooden pile.improper storage of gasoline container can result in a fire hazardous or explosion if not properl
Oct 1, 2024 · Penalty $2,500
Resolve - Class - 2
7 story building noticed storage zone adjacent from sidewalk shed not complying to code3307.4.7(2),no dot permit for street usage in front of 1743 .i noticed no 4ft barrier with mesh adjacent to storage zone an
Oct 1, 2024 · Penalty $2,400
Resolve - Class - 2
3308.5.3 i noticed a inadequate cables vertical safety system in place at the 5th floor of a active jobsite. i observed missing zero cable in various locations and loose netting. this creates a unsafe situatio
Oct 1, 2024 · Penalty $2,500
Resolve - Class - 1
Bc 3307.2.1 failure to comply with dot regulations: at time of inspection i observed active mobile crane operations in street area at exposure 1 with operations blocking adjacent businesses located at 1735 & 17
Sep 27, 2024 · Penalty $2,500
Active - Class - 2
Work not conform to approved construction documents and/or approved amendments: as noted at time of inspection for an active construction site observed at 1st basement level the wall shower as cmu and concrete
Jul 11, 2024 · Penalty $1,250
Resolve - Class - 1
150pm observed 3 workers at 4 floor working deck,requested for compent person to which workers responded "went away to get material".at 300pm competent person has return to site, 1rcny 3301-02(c)(10) and bc3301
Jun 4, 2024 · Penalty $2,530
Resolve - Class - 2
Exp1 sws not covering full width public sidewalk ,reviewed zd1 exterior wall height 44 feet from cellar-2 story,residential portion building wall height 67 feet.bc3307.6.2 stipulates structure higher than 40 fe
Jun 4, 2024 · Penalty $2,400
Resolve - Class - 1
Observed 3rd fl slab poured around all exposures. upon review the department records observed site under swo complaint# 2332222 and partial rescind on 4/3/23 for no work above the fence line no work 10 feet int
Dec 5, 2023 · Penalty $5,000
Resolve - Class - 2
Failure to safeguard all persons and property affected by construction operations.at time of inspection of nb observed shoring taking place at exp #1 adjacent property driveway with 2ingap creating unsafe condi
Mar 1, 2022 · Penalty $5,000
Resolve - Class - 2
Documents to be kept onsite.at the time of my inspection,i observed anexcavator in operation near exp1.however,the competent person could not locate or provide any vibration or monitoring reports for review.thi
Nov 26, 2021 · Penalty $625
Resolve - Class - 2
Work contrary to construction documents.at the time of my inspection,iobserved a major condition that did not conform to the site safety plans ssp-100.00 and ssp-110.00.the primary means of egress was routed th
Nov 26, 2021 · Penalty $620
Resolve - Class - 2
Failure to safeguard all persons and property affected by constructionoperations.at the time of my inspection,i observed a worker adjusting a sign at exp2 without wearing a hard hat or fall protection harness w
Nov 26, 2021 · Penalty $625
Resolve - Class - 1
Failure to perform duties of construction superintendents. at the timeof my inspection,i observed 3 workers on site w/no construction superintendent or competent person present. for workers & public safety,code
Sep 27, 2021 · Penalty $500
Resolve - Class - 1
Failure to perform duties of construction superintendents at the time of my inspection,i observed 3 workers on site w/no construction superintendent or competent person present. for worker & public safety,code
Sep 27, 2021 · Penalty $2,500
Resolve - Class - 2
Sec. bc3303.7.2 inadequate fire extinguishers. at the time of my inspection,i observed that there were no inspection tags for the 2 portablefire extinguishers,& that 1 of them was partially depressurized. these
Sep 27, 2021 · Penalty $620
Resolve - Class - 2
Job site fence not constructed or maintained pursuant to subsection. at time of inspection at proposed 8 story building observed construction gate swing outwards pedestrian sidewalk creating hazardous condition
Jul 19, 2021
Resolve - Class - 1
Failure to communicate required information to workers during pre-shift safety meeting at time of inspection of an active 8 story new building observed 3 workers performing foundation work.upon request from con
Jun 21, 2021 · Penalty $2,500
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D7)
- Year built
- 2022
- Floors
- 8
- Residential units
- 40
- Building area
- 49,013 ft²
- Lot area
- 6,782 ft²
- Zoning
- R7X
- Community board
- 203
- Council district
- 17
- Block / lot
- 3015 / 25
- Assessed value
- $2,017,350
- Landmark / historic district
- No
Questions about 1745 West Farms Road
Who owns 1745 West Farms Road?
The owner of record in NYC Department of City Planning PLUTO data is 1745 West Farms Road LLC.
Does 1745 West Farms Road have violations?
NYC HPD has no housing violations on record for this property.
Is 1745 West Farms Road rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 1745 West Farms Road built?
City records list 2022 as the year it was built.
How many apartments are in 1745 West Farms Road?
It has 40 residential units and 41 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.