roofy

1156 East 165 Strreet

Bronx, NY 10459BBL 2-02756-0090Map

Owner of record: Hp Whitlock II Housing Development Fund Company,

1156 East 165 Strreet is an elevator apartment building built in 2025 in Bronx, 10459. It has 251 residential units across 14 floors. The owner of record is Hp Whitlock II Housing Development Fund Company,. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
4
ECB violations
29
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 4

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 7, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 17, 2021

    Dob violation - dismissed
  • Immediate emergency anythingoptional

    Install approximately 170 linear feet of sidewalk shed along exposure# 2 and wrap around approximately 50 linear feet into exposure#1

    Nov 25, 2020

    Dob violation - dismissed
  • Immediate emergency anythingoptional

    Install approx. 140ft of sidewalk shed along exp#1. front of the building

    Feb 8, 2019

    Dob violation - dismissed

ECB violations · 29

  • Class - 2

    Atoi of a proposed 14-story nb, the job site was non-active with no personnel present. the site exceeded 22,000 sq ft.required a designated watch person. i observed that no watch person was provided maintained

    Aug 27, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    At the time of my inspection of a 14 story nb approximately 22712 square feet, i observed closed site with no construction activity. upon shouting at perimeter and banging on fence and door to alert watchperson

    Aug 8, 2026 · Penalty $2,530

    Resolve
  • Class - 2

    Obs. active constr. ops. for hvac work at mult. flrs. contr. to stipulations of ahv permit no. x00992202-i1-gc. workers performed hvac installation while permit auth. only housekeeping, framing, sheetrock & fin

    Aug 1, 2026 · Penalty $1,280

    Resolve
  • Class - 2

    At time of inspection, observed proposed 14-story building where material storage was located at exposure 4 without required solid 4-foot barriers separating the storage area from the public walkway. condition

    Jul 6, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection, during high wind conditions, observed proposed 14-story building with horizontal safety netting at approximately the 11th floor not properly secured. loose netting may become dislodged an

    Jul 6, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection, 14-story building observed with missing debris netting between the perimeter fence and sidewalk shed at exposures 3 and 4 adjacent to neighboring property at 1142 e. 165 street, apt 1c. c

    Jul 6, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    At the time of inspection of a proposed 13-story new building, i observed no watch person on site or in the area of the premises. the job site exceeded a 22712 sq. ft. footprint and required a designated watch

    Jun 11, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Observed 14 nb on super structure phase @ 7th fl working deck. adjacent property @ expo 3 with inadequate adjacent property protection as per code and approved ssp plan review on site. no roof protection instal

    Apr 22, 2026 · Penalty $5,000

    Resolve
  • Class - 2

    At the time of inspection of a proposed 14-story new building, i observed no watch person on site or in the area of the premises. the job site exceeded a 22,000 sq. ft. footprint and required a designated watch

    Feb 22, 2026 · Penalty $2,500

    Resolve
  • Class - 1

    Observed active jobsite in soe/foundation operations. guardrail system installed around perimeter of soe @ exposure 1 & 4are inadequate. the guardrail system is missing toe boards and the the system is not conn

    Jan 30, 2026 · Penalty $5,000

    Resolve
Show 19 more ↓
  • Class - 2

    Observed construction fence installed around perimeter of jobsite at exposure 1 &4. the construction fence does not have viewing panels installed every 25 ft as per code requires.provide/viewing panels every 25

    Jan 30, 2026 · Penalty $1,000

    Resolve
  • Class - 1

    A proposed 14 story nb active site at soe / foundation phase. upon review of cs logs. cs not present. no cs logs was presented, jeffrey pizarro reg#29769 as the designated construction superintendent. however,

    Dec 11, 2025 · Penalty $10,030

    Resolve
  • Class - 2

    14 story nb site currently in the soe/foundation phase,observed to be proceeding contrary to the approved support of excavation (soe) plans.exp#1,missing and/or inadequate whalers, rakers,and heel blocks, resul

    Dec 10, 2025

    Resolve
  • Class - 2

    Proposed 14-story nb active site. observed a yellow metal fdny flammable liquid storage box containing diesel fuel left unlocked/accessible. upon requesting the nyc fdny permit for fuel use/storage, none were v

    Dec 10, 2025 · Penalty $1,280

    Resolve
  • Class - 1

    At a proposed 14-story nb site in the soe/foundation phase, work was observed proceeding at the adjacent property. at excavation area #2, the adjacent wall was not weatherproof, exposing the structure to potent

    Dec 10, 2025 · Penalty $5,030

    Resolve
  • Class - 1

    At time of inspection of a 14-story new building, active site at excavation phase upon reviewing the approve ssp plan i noticed jobsite ramp and roadway barriers not as per plan roadway has concrete and timber

    Oct 20, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection of 14-story new building,active site at excavation i observed drilling operation inside to site and dewatering into sewer line not as per code 3303.5.3 clogging. i observed workers on road

    Oct 20, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection of a 14-story new building, active site excavation phase with drilling operation and air pollution not as per code 3303.5.4 i observed dust and airborne particles from construction during

    Oct 20, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    At time of inspection of a 14-story new building, active site at excavation upon requesting site safety manger onsite for pre shift meeting,optical monitoring,vibration monitoring and pre construction survey no

    Oct 20, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    At time of inspection of inspection of a 14-story new building, active site i observed concrete wall with con edison electrical power wire inside jobsite. upon review the approve soe and ssp plan condition not

    Oct 20, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    Observed at exp4 swing fence entering into public sidewalk hazard to pedestrians created strike by construction equipment leads to injuries or fatal.bc3307.7.2 stipulates construction fence shall swing into ar

    May 16, 2025

    Resolve
  • Class - 2

    At the time of inspection demolition job site i observed construction fence has permit expired on : 08/20/2022 under job# x00580055-i1-fn.

    Mar 6, 2023

    Resolve
  • Class - 2

    Failure to maintain construction fence.at time of my inspection on a demolition sign-off site.observed that the construction fence had been poorly maintained.for instance,there is unlawful vancalized markings a

    May 5, 2022

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner. note at time of inspection at exp#1&2 multiple cracks & missing mortar observed sidewalk shed installed permit#x00131146 exp 3/11/2020 permit to demo not issue

    May 21, 2021 · Penalty $500

    Resolve
  • Class - 1

    Faailure to maintain bldg in code compliant manner. noted: at time of my inspection i observed at exp#1&2 multiple cracks & missing mortar from bricks also coping stone at roof level has areas where it is missi

    Apr 6, 2021 · Penalty $500

    Resolve
  • Class - 1

    Failure to maintain bldg in code-compliant manner.note: at exp.#1 & 2 observed multiple cracks & missing mortar from bricks also coping stone at roof level has areas where it is missing & some look lease.at exp

    Feb 8, 2021 · Penalty $1,563

    Resolve
  • Class - 1

    Failure to maintain. at time of inspection at exposure #1 observed step cracks, missing mortar joints and loose stucco. at exposure # 2 observed many missing and loose coping stones along with missing, loose an

    Nov 25, 2020 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#35305023h issued on 01-31-19 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01(d)(2). an acceptable certificate has not been filed despite the

    Nov 13, 2019

    Resolve
  • Class - 2

    Failure to maintain building in code complaint manner.at time of inspection the violating conditions are as follows 1)loose missing mortoar joints on the facade of exposure #1 2)cracks on the facade where 2)cra

    Jan 31, 2019

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D7)
Year built
2025
Floors
14
Residential units
251
Building area
233,220 ft²
Lot area
27,251 ft²
Zoning
R8A
Community board
202
Council district
17
Block / lot
2756 / 90
Assessed value
$868,950
Landmark / historic district
No

Questions about 1156 East 165 Strreet

Who owns 1156 East 165 Strreet?

The owner of record in NYC Department of City Planning PLUTO data is Hp Whitlock II Housing Development Fund Company,.

Does 1156 East 165 Strreet have violations?

NYC HPD has no housing violations on record for this property.

Is 1156 East 165 Strreet rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 1156 East 165 Strreet built?

City records list 2025 as the year it was built.

How many apartments are in 1156 East 165 Strreet?

It has 251 residential units and 252 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.