1098 Sheridan Avenue
Bronx, NY 10456BBL 2-02456-0100Map
Owner of record: NYC Department Of Education
1098 Sheridan Avenue is a school building built in 1931 in Bronx, 10456. The owner of record is NYC Department Of Education. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 24
- ECB violations
- 85
- HPD complaints
- 8
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 24
- Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed
Show 14 more ↓
- Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 9, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 9, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 9, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 9, 1994
Dob violation - dismissed
ECB violations · 85
- Class - 2
Re-issue #35717270x. occupancy contrary to that allowed by the certificate of occupancy of building department records. noted: c of o #1650 does not include gymnasiums and auditorium. remedy: discontinue illega
Mar 27, 2026 · Penalty $3,125
Active - Class - 2
Failure to maintain building in code-compliant manner. noted: interiorfire proof doors do not self-close properly at, 4th flr-staircase "d","e". 3rd flr-"gym". 2nd flr-main office. 1st flr-"exit 9". basement-"l
Mar 27, 2026 · Penalty $1,250
Active - Class - 2
Exit door not self-closing. noted: exterior exits #"9" and "4" do not self-close properly on 1st floor. remedy: repair/replace door.
Mar 27, 2026 · Penalty $625
Active - Class - 2
Failure to maintain building in code-compliant manner. noted: classroom doors do not self-close properly at, 1st flr-10, 11, 7, 1. remedy: repair and/or replace.
Mar 27, 2026 · Penalty $1,250
Active - Class - 2
Exit door not self-closing. noted: exterior exit near rm #8 does not self-close properly when tested. remedy: repair/replace door.
Mar 27, 2026 · Penalty $625
Active - Class - 2
Reissue: 35684636n-occupancy contrary to that allowed by cert of occupancy on building code. no valid c of o on file. c of o #46342 does notreflect 4 story. remedy: comply with code.
May 16, 2025 · Penalty $3,125
Active - Class - 2
Reissue #35672114h. occupancy contrary to that allowed by the certificate of occupancy or building department records. at time of my inspection, i observed the c of o #46342 does not reflect 4-story school buil
Jul 19, 2024 · Penalty $10,000
Active - Class - 2
Failure to maintain building in code-compliant manner:use of prohibited door and/or hardware per bc 1008.1.8; 27-371(j).note:observed at various locations throughout entire school building,exit doors have door
Mar 21, 2023 · Penalty $625
Resolve - Class - 2
Stair and/or floor identification signs missing and/or defective.note:observed throughout entire school building,corridors and/or staircase are missing location id signs for each fl landing providing fl level s
Mar 21, 2023 · Penalty $625
Resolve - Class - 2
Reissued #35650835k-failure to maintain building in code-compliant manner.noted:observed at 4th fl staircase leading to bulkhead/roof missing handrail on left hand side & missing handrail bracket on right hand
Mar 21, 2023 · Penalty $1,562
Resolve
Show 40 more ↓
- Class - 2
Occupancy contrary to that allowed by certificate of occupancy or building dept records.note:observed c of o #46342 does not reflect 4-story school building with 1-story mini-school,playground & parking with ap
Mar 21, 2023 · Penalty $1,250
Active - Class - 2
Re-issued #35548238l failure to maintain building in code compliant manner.noted:at bulkhead leading to roof stairway handrail missing bracket that connects to wall.remedy:repair and/or replace
Mar 14, 2022 · Penalty $1,562
Resolve - Class - 2
Re-issue #35548240k exit door not self closing.noted:at first floor exit #7 door frame rusted affecting closing of all doors.remedy:repair/replace door
Mar 14, 2022 · Penalty $1,562
Resolve - Class - 2
Reissue: 35486628x failure to maintain bldg in code compliant manner: noted: illumination for exit,exit discharges & public corridors per bc 1006.1;27-381. noted: gym,7 exit emergency lighting not working water
Feb 17, 2021 · Penalty $1,562
Resolve - Class - 2
Reissue: 35316823t failure to maintain bldg in code compliant manner. noted: roof level stairway handrail missing bracket @ top. remedy: comply w/code.
Feb 17, 2021 · Penalty $1,562
Resolve - Class - 2
Reissue: 35486629h exit doors not self closing: noted: at 1st fl exit 7,all 3 frame are rusted & exit door not closing properly. remedy: comply w/code.
Feb 17, 2021 · Penalty $1,562
Resolve - Class - 2
Boiler# 01, tube leak-boiler# 02, corroded nipple w/valve leak-open electrical box near chimney-hwh leak-boiler room floor flooded; correct all violating conditions, submit a certificate of correction.
Jun 5, 2020 · Penalty $625
Active - Class - 2
Reissue#35316821x failure to maintain bldg in code compliant manner. illumination for exits,exit discharges & public corridors per bc 1006.1;27-381. noted: at gym,7 exit emergency lighting inoperative when test
Apr 14, 2020 · Penalty $1,562
Resolve - Class - 2
Reissue#35386465m failure to maintain bldg in code compliant manner. noted: at roof level stairway,handrail loose due to missing bracket. remedy: repair/replace.
Apr 14, 2020 · Penalty $1,562
Resolve - Class - 2
Reissue#35386466y exit door not self closing. noted: at 1st fl,exit #7,all 3 floors frames are rusted & exit doors do not cxlose properly. remedy: repair/replace doors.
Apr 14, 2020 · Penalty $1,562
Resolve - Class - 2
Sec. 28-301.1 unlawful display of artwork in corridors greater than 20% per fdny 2018 code'fc 803.3.2. noted: artwork displayed in corridors is greater than 20% allowed per fdny code. remedy: comply w/notice of
Apr 14, 2020 · Penalty $1,250
Resolve - Class - 2
Reissued 35316823j failure to maintain building in code compliant manner. noted defects on roof level stairway bracket of handrail missing. remedy: repair or replace
Mar 15, 2019
Resolve - Class - 2
Reissue vio#35316824l failure to maintain building in code compliant manner:observed-at lower gym near of water fountain vertical&horizontalcracks,also at rear of building rooms#5,9,11 cracks above doors. remed
Mar 15, 2019
Resolve - Class - 2
Exit door not self closing. noted exit #8 left side also exit #2, exitno.7 2 middle post for framing at bottom are rotten. remedy: repair/orreplace doors
Mar 15, 2019
Resolve - Class - 2
Failure to comply w/commissioner's order contained in summons/violation #35330758n issue don 05/03/18 and to file a certificate of correction pursuant to 28-201.1 and 14cny 102-01. rmdy: comply with commissione
Oct 27, 2018
Resolve - Class - 1
Failure to maintain building in code compliant manner. at the time of inspection at room 316 (3rd floor) inside the classroom an apprx 1' x 5' chunk of plasters collapse from ceiling beams apprx 10'10" from bea
May 3, 2018
Resolve - Class - 2
Failure to maintain in code-compliant manner.noted:at 1st fl of rear bldg rms#5,9,and 11 walls have cracks above doors.rem:repair or replace.
Feb 6, 2018
Resolve - Class - 2
Re-issue 35235528m.failure to maintain bldg wallsor appurtenances.note:water penetration,spalling masonry at bulkhead(stairs d)a t4th fl at 3rd fl(down stairwell of a&b)as well as 3 areas in bsmt(boiler rem)nor
Feb 6, 2018
Resolve - Class - 2
Re-issue 35235530l.failure to maintain bldg in code-compliant mannernote:at auditorium at both emergency exits from stage means of egress blocked by debris and storage door can not open.rem:comply w/nov remove
Feb 6, 2018
Resolve - Class - 2
Re-issued 35235527k.failure to maintain bldg in code-compliant manner.lack of emergency lighting for exit,exit discharges and public corridors per bc 1006.1;27-345.note at various locations on all fl emergency
Feb 6, 2018
Resolve - Class - 2
Failure ot maintain bldg in code-compliant manner.note:at roof level stairway handrail missing bracket also on 1st fl exp#3 rear exit#3step tread covers loose and bouncing can be a tripping hazard.3rd and 4th s
Feb 6, 2018
Resolve - Class - 2
Failure to maintain bldg in code-compliant manner.note at 4th fl exite 1 and 2 both sides wall has hole and spalling concrete also calcium build up on stairwell side of exit at gym rear exit door leak above lin
Feb 5, 2018
Resolve - Class - 3
Failure to maintain bldg in code compliant manner.noted: water penetration, spalling masonry at bulkhead (stair d); at 4th flr (sair a,b) and at 3rd floor (down stairwell of a,b). as well as three areas in base
Mar 27, 2017
Resolve - Class - 2
Emergency lighitng/signs(s) not working.failure to maintain building in code compliant manner, lack of emergency lighting fo rexits, exit discharges and public corridors per bc 1006.1 27-542. noted: the follo
Mar 27, 2017
Resolve - Class - 3
Failure to maintain building in code compliant manner. note: at auditorium, at both emergency exits from stage, mean of egress blocked by excessive debris/storage, pen was use to "pin lock door" preventing door
Mar 27, 2017 · Penalty $500
Resolve - Class - 2
Failure to maintain bldg in code compiant manner. noted: at lower gym,step cracks (2 separate(1) t upper wall; (1) at lower wall next to water fountain) spalling masonry and step cracks on wall and ceiling near
Mar 27, 2017
Resolve - Class - 2
Re-issue #35016409j.failure to maintain building walls or appurtenances.water penetration at roof throughout and (bulk) walls. remedy:complywith notice of violation.
Sep 10, 2015
Resolve - Class - 3
Water penetration at roof bulk head (walls). remedy: maintain as per code.
Apr 11, 2013
Resolve - Class - 2
Door note closing. at basement exit 12 discharge doors. at 1st stry main exit discharge/entry doors,stair c & exit 1 discharge door & stair b exit vestibule doors. at 2nd stry cross corridor doors near room 209
Jun 29, 2012
Resolve - Class - 2
Water penetrating building envelope. at 2nd stry near room 218,stair a/b enclosure. at 3rd stry near room 363. at 4th stry a/b enclosure. rem:repair defects noted.
Jun 29, 2012
Resolve - Class - 2
Reissue: 34863158p the plaster on wall is spalling located at stair a & b 4th fl level. remedy: repair &/or replace plaster.
Sep 22, 2011
Resolve - Class - 2
Exterior brick facade has become porous & allowing rain into the bldg causing interior damages in room 455, 411, stair a,b,e,f, 4th fl level 3rd fl level gymnasium 1st fl auditorium remedy: water-proof exterior
Jun 29, 2010
Resolve - Class - 2
Classroom wooden fl is rotten & missing causing a tripping hazard located in room 108 on the 1st fl level remedy: repair / replace wooden fl
Jun 29, 2010
Resolve - Class - 2
Corridor smoke doors are dragging on the fl causing doors not to open & close properly located on the 2nd & 3rd fl level remedy: repair / replace corridor smmoke doors
Jun 29, 2010
Resolve - Class - 2
Reissue: 34760793m the plaster is spalling off the walls & ceiling located @ rooms 455, 411 stair a,b,e & f on the 4th fl level gymnasium 3rd fl level 1st fl auditorium (adjacent to the windows) remedy: repair
Jun 29, 2010
Resolve - Class - 2
Corridor hallway is being used as a storage area consisting of speakers,popcorn machines,boxes & computers. remedy: remove obstruction.
Feb 3, 2009
Resolve - Class - 2
Reissue: 34508752l exit & corridor smoke door are not self closing. noted: doors are dragging on the flr leaving doors in an open position. remedy: repair/replace exits & corridors doors.
Feb 3, 2009
Resolve - Class - 2
34639732y glazed brick column is vertically cracked approx 2'feet longadjacent. to sheridan ave in the gymnasium at basement level. remedy: repair brick column.
Feb 3, 2009
Resolve - Class - 2
Reissue: 34639731m,34639624r the plaster is spalling on the ceiling located at exit "e & f" on the 1st flr level & room 455 (asst principalsoffice) on the 4th flr level.
Feb 3, 2009
Resolve - Hazardous
Interior glazed brick wall is cracked vertically in the gynasium on basement level approx. 2'long adjacent to sheridan ave remedy:repair brick wall
Mar 14, 2008
Resolve
Complaints
- Nonconst
Vermin
Apr 1, 2011 · Apt F8
Close - General
Floor
Dec 13, 2006 · Apt WKB
Close - Paint/plaster
Ceiling
Dec 13, 2006 · Apt WKB
Close - General
Floor
Dec 13, 2006 · Apt WKB
Close - General
Floor
Dec 13, 2006 · Apt WKB
Close - General
Windows
Dec 13, 2006 · Apt WKB
Close - Heating
Heat related
Dec 13, 2006 · Apt WKB
Close - Heating
Heat related
Dec 13, 2005 · Apt WKB
Close
Sales history
No recorded sales in our data
Building details
- Building type
- School building (W1)
- Year built
- 1931
- Floors
- 4
- Residential units
- —
- Building area
- 107,613 ft²
- Lot area
- 82,606 ft²
- Zoning
- R7-1
- Community board
- 204
- Council district
- 16
- Block / lot
- 2456 / 100
- Assessed value
- $7,066,800
- Landmark / historic district
- No
Questions about 1098 Sheridan Avenue
Who owns 1098 Sheridan Avenue?
The owner of record in NYC Department of City Planning PLUTO data is NYC Department Of Education.
Does 1098 Sheridan Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 1098 Sheridan Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 1098 Sheridan Avenue built?
City records list 1931 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.