roofy

115 Ft Washington Avenue

Manhattan, NY 10032BBL 1-02136-0245Map

Owner of record: Royal Charter Properties, INC.

115 Ft Washington Avenue is a garage / gas station built in 1964 in Manhattan, 10032. The owner of record is Royal Charter Properties, INC.. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
42
ECB violations
17
HPD complaints
12

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 42

  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2023)

    Jun 23, 2024

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 13, 2023

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 22, 2023

    Dob violation - active
  • Construction other optional

    C-construction other optional

    May 5, 2023

    Dob violation - active
  • Construction other optional

    Cracks,spalls, delaminatn of conc slabs,beams,columns,pre-cast tees @ sevrl locatns,exposd,corrodd reinforcmt,faild expansn jnts&watrproof membranes,extns shoring,incomplte rprs pose potentl hazard retain lic nys rdp 2 file permant repair drwgs by 7/28/23. permanent rpair wrk by permit to begin by 8/25/23

    May 4, 2023

    Dob violation - active
  • Construction other optional

    The occupied parking garage ,with concrete framing is in a state of disrepair , with cracks,concrete spalling,and exposing steel reinforcement at various locations, through out.

    May 2, 2023

    Dob violation - dismissed
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2022)

    Apr 22, 2023

    Dob violation - active
  • Construction other optional

    Failure to maintain. at time of insp observed severe deterioration to structural elements to include reinforced concrete columns where large sections of concrete has detached exposing steel re-bar furthering deterioration compromising structural integrity. multiple area's of defect to include slab, attachment plates. note:vertical movement on

    Apr 21, 2023

    Dob violation - active
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2021)

    Aug 21, 2022

    Dob violation - active
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2020)

    Jun 20, 2021

    Dob violation - active
Show 32 more ↓
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Apr 29, 2021

    Dob violation - active
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2019)

    Jun 29, 2020

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 27, 2019

    Dob violation - dismissed
  • Retaining wall none

    Failed to file cycle 1 technical report by 12/31/2018 per rcny 103-09

    Oct 1, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 7, 2019

    Dob violation - dismissed
  • Construction other optional

    Ftm:brick arch has cracks open joints&deterior brick@multi locations stone walls deterior in multi loc.steel lintels@north end severely corroded.exist steel shor severely corroded&part collap in multi loc water infiltration throughout.own retain nysp engineer to eval entire tunnel struct&dsgn reprs under prmt wrk st 7/22/19 prmt s/o by 11/1/19

    May 15, 2019

    Dob violation - dismissed
  • Construction other optional

    Ftm:brick arch@tunnel roof has cracks&open joints@multiple locations exist shor severely corroded&part collap in multiple locations.steel lintels@north end severely corroded.immed discontinue parking lot use& install barriers to prevent vehicles from driving over damaged area of tunnel.pe engineer to eval entire tunnel&provide rept feu by 5/31/19

    May 15, 2019

    Dob violation - dismissed
  • Construction other optional

    Emg wrk:brick arch@tunnel roof has cracks&open joints@multi locations existing shoring severely corroded&part collapsed in multi locations steel lintels@north end of tunnel severely corroded.immed instl temp shoring@direction&under continuous direct supervision of pe engineer work done by licensed contr.file prmt w/in 2 days wrk start by 5/16/19

    May 15, 2019

    Dob violation - dismissed
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2018)

    Mar 18, 2019

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Feb 16, 2019

    Dob violation - dismissed
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2017)

    Mar 27, 2018

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Feb 2, 2018

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Nov 2, 2017

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 12, 2017

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2017

    Dob violation - dismissed
  • Facade safety program facade required

    Fisp-facade safety program facade required

    Feb 21, 2017

    Dob violation - dismissed
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 in 2016

    Feb 16, 2017

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Feb 2, 2017

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Nov 2, 2016

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2016

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Jun 2, 2016

    Dob violation - dismissed
  • Residential elevator periodic inspection/test elevatorrequired

    Failure to perform category 5 inspection

    Jun 1, 2016

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2015

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 26, 2013

    Dob violation - resolved
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Jun 3, 2013

    Dob violation - dismissed
  • Facade facade optional

    Unsafe report filed

    Feb 21, 2012

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Jan 1, 2012

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 23, 2008

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Oct 1, 2005

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 18, 2005

    Dob violation - resolved

ECB violations · 17

  • Class - 2

    1) provide a 2nd light fixture in the car (a17.1 2.14.7.1.1) 2) the glass in the hoistway is not code compliant (provide a mesh over the glass)(ýc26-1800.6¨ 27-987(2)) 3) the elevator is releveling too often. 4

    Dec 17, 2025 · Penalty $3,125

    Active
  • Class - 1

    Unlawful act. failure to comply with commissioner's order. vio: 35686156n issued 08/23/2024 required the owner to provide safety measures ata parking structure filed as unsafe. at the time of inspection, on 10/

    Oct 12, 2024 · Penalty $2,500

    Resolve
  • Class - 1

    28-323.8 rcny 103-13(5)failure to secure public safety and/or make thebuilding's structure and appurtenances conform to the previous or admin code after unsafe notification filed by qpsi#unps-m0000199 dated 03/

    Aug 23, 2024 · Penalty $6,250

    Resolve
  • Class - 1

    Failure to comply with the commissioner's order in dob violation vio23-01277,dated 5/2/2023.respondent was required to submit an engineer's report concerning structurally deficient conditions.as of 10/11/2023,a

    Oct 11, 2023

    Resolve
  • Class - 1

    Failure to comply with the commissioner's order in dob violation vio23-01277, dated 5/2/2023. respondent was required to submit an engineer's report concerning structurally deficient conditions. as of 10/11/202

    Oct 11, 2023

    Resolve
  • Class - 1

    Failure to maintain building in code compliant manner. noted : throughout the parking garage on all floors observed severe structural deterioration, which includes some sections of concrete that are missing, ex

    May 2, 2023 · Penalty $1,250

    Active
  • Class - 1

    Failure to maintain building. at time of insp. observed severe deterioration to structural elements to include reinforced concrete columns where large sections of concrete has detached exposing steel re-bar fur

    Apr 21, 2023 · Penalty $2,500

    Active
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#35366081p issued on 08/29/19 & to file a cert of correction pursuant to 28-2011 & 1rcny 102-01(d)(2). remedy: file a cert of correction.

    Jun 29, 2020 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#39002958k issued on 05/15/19 & to file a cert of correction pursuant to 28-201.1 & 1rcny 102-01. no cert of correction filed. remedy: comply w/comm'

    Feb 27, 2020 · Penalty $3,125

    Resolve
  • Class - 1

    Failure to maintain exterior building facade and appurtenances.note;atthe time of inspection facade observe defects;exposure#2 south facade at various location such as between 7/8 floor 14 concrete column from

    Aug 29, 2019 · Penalty $2,500

    Resolve
Show 7 more ↓
  • Class - 2

    Removal of safety measure such as sidewalk sheds without department approval.note:at the time of inspection building facade was still designated as unsafe.the amended facade report received on 08-23-2019.had no

    Aug 29, 2019

    Resolve
  • Class - 1

    Observed at lower level electrical room ceiling, structural steel beam supported by approximately 15 steel columns are in complete disrepair. steel columns rusted and rotted, split apart and have become displac

    May 15, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to provide safety measure such as sidealk sheds,fence, etc where require to protect and secure public safety from documented unsafe facade as per 1rcny 103-04. facade technical reort file "unsafe" by pe

    Apr 20, 2017 · Penalty $6,000

    Resolve
  • Class - 2

    Noted at garage 7th fl & 8th fl roof top no mounted bumpers at perimeter walls for parking spaces perpendiculars and adjacent to masonry parapet space cited in previous ecb nov#34813647k issued 10/24/09 also ex

    Nov 19, 2011 · Penalty $1,250

    Resolve
  • Class - 2

    Fail to maintain fl mounted bumpers at perimeter walls. observed: at flrs 7 & 8 of premises, existing masonry perimeter walls adjacent motor vehicle parking spaces, no floor mounted non combustible floor bumpe

    Oct 24, 2009 · Penalty $800

    Resolve
  • Non-hazardous

    Failure to post the "c of o". remedy: post the certificate.

    Dec 13, 2005 · Penalty $250

    Resolve
  • Non-hazardous

    Failure to maintain building. defect is expose concrete beams re-bar exposed at cellar and sub cellar levels, cracks on floor, with chunks concrete missing. temporary shoring provide, make all necessary repair

    Feb 11, 1999 · Penalty $2,500

    Active

Complaints

  • Water leak

    Heavy flow

    Jul 13, 2024 · Apt 1B

    Close
  • Unsanitary condition

    Mold

    Jul 13, 2024 · Apt 1B

    Close
  • Unsanitary condition

    Mold

    Jul 13, 2024 · Apt 1B

    Close
  • Heating

    Heat related

    Nov 20, 2006 · Apt 6B

    Close
  • Plumbing

    Water supply

    Sep 6, 2006 · Apt 6B

    Close
  • Paint/plaster

    Wall

    Sep 6, 2006 · Apt 6B

    Close
  • Nonconst

    Janitor/super

    Sep 6, 2006 · Apt 6B

    Close
  • Nonconst

    Janitor/super

    Sep 6, 2006 · Apt 6B

    Close
  • Heating

    Heat related

    Dec 16, 2005 · Apt 6B

    Close
  • Appliance

    Electric/gas range

    Aug 6, 2004 · Apt 4C

    Close
Show 2 more ↓
  • Plumbing

    Basin/sink

    Aug 6, 2004 · Apt 4C

    Close
  • Paint/plaster

    Wall

    Aug 6, 2004 · Apt 4C

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Garage / gas station (G1)
Year built
1964
Floors
8
Residential units
—
Building area
527,604 ft²
Lot area
195,350 ft²
Zoning
R8
Community board
112
Council district
10
Block / lot
2136 / 245
Assessed value
$14,263,200
Landmark / historic district
No

Questions about 115 Ft Washington Avenue

Who owns 115 Ft Washington Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Royal Charter Properties, INC..

Does 115 Ft Washington Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 115 Ft Washington Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 115 Ft Washington Avenue built?

City records list 1964 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.