509 West 167 Street
Manhattan, NY 10032BBL 1-02123-0104Map
Owner of record: 509 West 167th Street LLC
509 West 167 Street is an elevator apartment building built in 2023 in Manhattan, 10032. It has 7 residential units across 6 floors. The owner of record is 509 West 167th Street LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 0
- ECB violations
- 21
- HPD complaints
- 13
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 0
No DOB violations on record
ECB violations · 21
- Class - 2
Erect new 7 story building .observed active site and permit ,cp present , upon inspection noted sws constructed contrary to approved documents. on drawings showing 5 icual bay , ercted 3 diferent sizes bay .
May 18, 2023 · Penalty $3,125
Resolve - Class - 2
Observed temporary platforms at the elevator shaft and stair shaft at 1st and 2nd flrs, open, accessible and in use. upon review of pe-aprvd design drawings (dd), i found that the dd called for l-brackets bolte
Feb 22, 2023
Resolve - Class - 2
Failure to comply with dot regulations as per 34 rcny 2-05 and admin code provisions 19-107, 19-108 or 19-121. observed a trailer placed in the street at exp#1. upon review of dot permits displayed at the prop
Feb 22, 2023 · Penalty $625
Resolve - Class - 1
Failure to protect/properly protect adjoining properties during construction ops. observed proposed 6 str nb at 2nd fl, erecting steel beams for 3rd fl, with work taking place directly over the adj prop courtya
Feb 22, 2023 · Penalty $625
Resolve - Class - 2
Proposed 6 str nb at 2nd flr, framing 3rd flr. obsvd columns at rear exp#3 placed on top of foundation wall w/ approx. 1in spacers, + the left column had a corner brace welded but not bolted to column or header
Feb 22, 2023 · Penalty $625
Resolve - Class - 2
Work in progress . i proceeded to ask. competent person. rafael garcia. for design drawings. /plans for sidewalk shed. and he responded by saying that he did not have one on site that. supposedly. the boss. had
Jan 31, 2023
Resolve - Class - 2
At time of inspection observed temporary platforms over the staircase and elevator upon request to view design drawings none were provided. provide design for temporary platforms at elevator shaft and stairwell
Nov 14, 2022 · Penalty $3,125
Resolve - Class - 2
At time of inspection observed cellar level with no temporary lighting was provided. hazard of trips and falls exist. provide temporary lighting for cellar level
Nov 14, 2022
Resolve - Class - 2
At time of inspection i observed installed cmu block wall with missing continuous rebar at exp 2 & 4 and as per plan.
Nov 14, 2022
Resolve - Class - 2
At time of inspection observed no overhead protection for at exposure 2 of adjoining property courtyard. hazard of stuck-by exist for tenant of the adjoining building provide overhead protection at exposure 2 o
Nov 14, 2022
Resolve
Show 11 more ↓
- Class - 1
At the time of inspection on proposed 6 story nb active jobsite, i observed in places at basements installed steel & 4x4 wood props used as reshores to support 1st floor . upon request for pe design drawing for
Nov 14, 2022 · Penalty $6,250
Resolve - Class - 2
Time of inspection open active site observed construction activities in progress, upon review i determined that dot permit was expired and never be renewed. provide and renew dot permit .provide and renew dot p
Sep 9, 2022
Resolve - Class - 2
Time of inspection observed open active site construction activities in progress competent person and 2 workers on site. upon request to see superintendent log book none was provided by competent person. cs mus
Sep 9, 2022
Resolve - Class - 2
Failure to comply with c31 standards for concrete cylinder test samples:as noted:at time of my inspection observed 5 test concrete cylinder stored next to construction fence contrary to c31 standard for concret
Jun 23, 2022 · Penalty $2,500
Resolve - Class - 2
Failure to perform proper concrete without water procedures.as noted at time of my inspection observed without on side of excavation and dump on the site on inquiring for the washout box which was shown on the
Jun 23, 2022 · Penalty $2,500
Resolve - Class - 2
Failure to maintain construction fence.note:at the time of my inspection on a non-active jobsite,i observed that the construction fence has been poorly maintained.for instance,multiple construction fence panels
Apr 25, 2022
Resolve - Class - 2
Posting of project information panel.note:at the time of my inspectionon a non-active jobsite,i observed that there were no project information panels installed on the construction fence at exposure#1.for the b
Apr 25, 2022 · Penalty $625
Resolve - Class - 2
Failure to provide parapet sign panel.at time inspection i observed sidewalk shed in place without project information panel,sidewalk shed parapet and construction sign not provided.remedy:comply with code.
Jan 14, 2022
Resolve - Class - 2
No info panel note atoi i observed sws in place w/o info panel on parapet.comply w/code-provide info panel
Dec 15, 2021
Resolve - Class - 2
Pedestrian protection not to code specs note atoi i observed const fence in place w/o viewing panel every 25'.comply w/code-provide viewing panels.
Dec 15, 2021 · Penalty $2,500
Resolve - Class - 2
Sec. 28-301.2 failure to maintain bldg in code cokpliant manner. defects noted there are keyed entry locking devices on the entry doors of both bedrooms & rear exit door at rear bedroom & front entry door at
Oct 8, 2015
Resolve
Complaints
- Plumbing
Water supply
Mar 10, 2015 · Apt 1
Close - Plumbing
Water supply
Mar 9, 2015 · Apt 1FL
Close - Electric
Wiring
Mar 8, 2015 · Apt 1
Close - Plumbing
Water supply
Mar 8, 2015 · Apt BLDG
Close - Plumbing
Water supply
Mar 7, 2015 · Apt 1
Close - Plumbing
Water supply
Mar 7, 2015 · Apt BLDG
Close - Heat/hot water
Entire building
Mar 6, 2015 · Apt BLDG
Close - Plumbing
Water supply
Mar 5, 2015 · Apt BLDG
Close - Plumbing
Water supply
Mar 5, 2015 · Apt BLDG
Close - Plumbing
Water supply
Mar 5, 2015 · Apt BLDG
Close
Show 3 more ↓
- Plumbing
Water supply
Mar 4, 2015 · Apt 1
Close - Plumbing
Water supply
Mar 4, 2015 · Apt BLDG
Close - Heating
Heat related
Dec 25, 2013 · Apt NA
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D3)
- Year built
- 2023
- Floors
- 6
- Residential units
- 7
- Building area
- 6,835 ft²
- Lot area
- 2,040 ft²
- Zoning
- R7-2
- Community board
- 112
- Council district
- 10
- Block / lot
- 2123 / 104
- Assessed value
- $587,250
- Landmark / historic district
- No
Questions about 509 West 167 Street
Who owns 509 West 167 Street?
The owner of record in NYC Department of City Planning PLUTO data is 509 West 167th Street LLC.
Does 509 West 167 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 509 West 167 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 509 West 167 Street built?
City records list 2023 as the year it was built.
How many apartments are in 509 West 167 Street?
It has 7 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.